mirror of
https://github.com/torvalds/linux.git
synced 2024-11-27 14:41:39 +00:00
b3ea2fe7e2
While UTF-8 characters can be used at the Linux documentation, the best is to use them only when ASCII doesn't offer a good replacement. So, replace the occurences of the following UTF-8 characters: - U+2010 ('‐'): HYPHEN - U+2013 ('–'): EN DASH - U+2019 ('’'): RIGHT SINGLE QUOTATION MARK Signed-off-by: Mauro Carvalho Chehab <mchehab+huawei@kernel.org> Link: https://lore.kernel.org/r/ccdd1bf45963a7748188a97c75f667b37bd43d2f.1620641727.git.mchehab+huawei@kernel.org Signed-off-by: Guenter Roeck <linux@roeck-us.net>
57 lines
1.7 KiB
ReStructuredText
57 lines
1.7 KiB
ReStructuredText
.. SPDX-License-Identifier: GPL-2.0
|
|
|
|
Kernel driver ltc2992
|
|
=====================
|
|
|
|
Supported chips:
|
|
* Linear Technology LTC2992
|
|
Prefix: 'ltc2992'
|
|
Datasheet: https://www.analog.com/media/en/technical-documentation/data-sheets/ltc2992.pdf
|
|
|
|
Author: Alexandru Tachici <alexandru.tachici@analog.com>
|
|
|
|
|
|
Description
|
|
-----------
|
|
|
|
This driver supports hardware monitoring for Linear Technology LTC2992 power monitor.
|
|
|
|
LTC2992 is a rail-to-rail system monitor that measures current,
|
|
voltage, and power of two supplies.
|
|
|
|
Two ADCs simultaneously measure each supply's current. A third ADC monitors
|
|
the input voltages and four auxiliary external voltages.
|
|
|
|
|
|
Sysfs entries
|
|
-------------
|
|
|
|
The following attributes are supported. Limits are read-write,
|
|
all other attributes are read-only.
|
|
|
|
in_reset_history Reset all highest/lowest values.
|
|
|
|
inX_input Measured voltage.
|
|
inX_lowest Minimum measured voltage.
|
|
inX_highest Maximum measured voltage.
|
|
inX_min Minimum voltage allowed.
|
|
inX_max Maximum voltage allowed.
|
|
inX_min_alarm An undervoltage occurred. Cleared on read.
|
|
inX_max_alarm An overvoltage occurred. Cleared on read.
|
|
|
|
currX_input Measured current.
|
|
currX_lowest Minimum measured current.
|
|
currX_highest Maximum measured current.
|
|
currX_min Minimum current allowed.
|
|
currX_max Maximum current allowed.
|
|
currX_min_alarm An undercurrent occurred. Cleared on read.
|
|
currX_max_alarm An overcurrent occurred. Cleared on read.
|
|
|
|
powerX_input Measured power.
|
|
powerX_input_lowest Minimum measured voltage.
|
|
powerX_input_highest Maximum measured voltage.
|
|
powerX_min Minimum power.
|
|
powerX_max Maximum power.
|
|
powerX_min_alarm An underpower occurred. Cleared on read.
|
|
powerX_max_alarm An overpower occurred. Cleared on read.
|