mirror of
https://github.com/torvalds/linux.git
synced 2024-11-23 04:31:50 +00:00
62287dce5d
dtc has new checks for I2C buses. Fix the warnings in unit-addresses in the unittests. drivers/of/unittest-data/testcases.dtb: Warning (i2c_bus_reg): /testcase-data/overlay-node/test-bus/i2c-test-bus/test-unittest14/i2c@0/test-mux-dev: I2C bus unit address format error, expected "20" drivers/of/unittest-data/overlay_15.dtb: Warning (i2c_bus_reg): /fragment@0/__overlay__/test-unittest15/i2c@0/test-mux-dev: I2C bus unit address format error, expected "20" Cc: Frank Rowand <frowand.list@gmail.com> Signed-off-by: Rob Herring <robh@kernel.org>
118 lines
2.1 KiB
Plaintext
118 lines
2.1 KiB
Plaintext
// SPDX-License-Identifier: GPL-2.0
|
|
|
|
/ {
|
|
testcase-data {
|
|
overlay-node {
|
|
|
|
/* test bus */
|
|
unittest_test_bus: test-bus {
|
|
compatible = "simple-bus";
|
|
#address-cells = <1>;
|
|
#size-cells = <0>;
|
|
|
|
unittest100: test-unittest100 {
|
|
compatible = "unittest";
|
|
status = "okay";
|
|
reg = <100>;
|
|
};
|
|
|
|
unittest101: test-unittest101 {
|
|
compatible = "unittest";
|
|
status = "disabled";
|
|
reg = <101>;
|
|
};
|
|
|
|
unittest0: test-unittest0 {
|
|
compatible = "unittest";
|
|
status = "disabled";
|
|
reg = <0>;
|
|
};
|
|
|
|
unittest1: test-unittest1 {
|
|
compatible = "unittest";
|
|
status = "okay";
|
|
reg = <1>;
|
|
};
|
|
|
|
unittest2: test-unittest2 {
|
|
compatible = "unittest";
|
|
status = "disabled";
|
|
reg = <2>;
|
|
};
|
|
|
|
unittest3: test-unittest3 {
|
|
compatible = "unittest";
|
|
status = "okay";
|
|
reg = <3>;
|
|
};
|
|
|
|
unittest5: test-unittest5 {
|
|
compatible = "unittest";
|
|
status = "disabled";
|
|
reg = <5>;
|
|
};
|
|
|
|
unittest6: test-unittest6 {
|
|
compatible = "unittest";
|
|
status = "disabled";
|
|
reg = <6>;
|
|
};
|
|
|
|
unittest7: test-unittest7 {
|
|
compatible = "unittest";
|
|
status = "disabled";
|
|
reg = <7>;
|
|
};
|
|
|
|
unittest8: test-unittest8 {
|
|
compatible = "unittest";
|
|
status = "disabled";
|
|
reg = <8>;
|
|
};
|
|
|
|
unittest_i2c_test_bus: i2c-test-bus {
|
|
compatible = "unittest-i2c-bus";
|
|
status = "okay";
|
|
reg = <50>;
|
|
|
|
#address-cells = <1>;
|
|
#size-cells = <0>;
|
|
|
|
test-unittest12 {
|
|
reg = <8>;
|
|
compatible = "unittest-i2c-dev";
|
|
status = "disabled";
|
|
};
|
|
|
|
test-unittest13 {
|
|
reg = <9>;
|
|
compatible = "unittest-i2c-dev";
|
|
status = "okay";
|
|
};
|
|
|
|
test-unittest14 {
|
|
reg = <10>;
|
|
compatible = "unittest-i2c-mux";
|
|
status = "okay";
|
|
|
|
#address-cells = <1>;
|
|
#size-cells = <0>;
|
|
|
|
i2c@0 {
|
|
#address-cells = <1>;
|
|
#size-cells = <0>;
|
|
reg = <0>;
|
|
|
|
test-mux-dev@20 {
|
|
reg = <0x20>;
|
|
compatible = "unittest-i2c-dev";
|
|
status = "okay";
|
|
};
|
|
};
|
|
};
|
|
};
|
|
};
|
|
};
|
|
};
|
|
};
|