mirror of
https://github.com/torvalds/linux.git
synced 2024-12-05 02:23:16 +00:00
93f7c27b4d
If the driver is built as a module, autoload won't work because the module alias information is not filled. So user-space can't match the registered device with the corresponding module. Export the module alias information using the MODULE_DEVICE_TABLE() macro. Before this patch: $ modinfo drivers/power/reset/zx-reboot.ko | grep alias $ After this patch: $ modinfo drivers/power/reset/zx-reboot.ko | grep alias alias: of:N*T*Czte,sysctrlC* alias: of:N*T*Czte,sysctrl Signed-off-by: Javier Martinez Canillas <javier@osg.samsung.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
85 lines
1.8 KiB
C
85 lines
1.8 KiB
C
/*
|
|
* ZTE zx296702 SoC reset code
|
|
*
|
|
* Copyright (c) 2015 Linaro Ltd.
|
|
*
|
|
* Author: Jun Nie <jun.nie@linaro.org>
|
|
*
|
|
* This program is free software; you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License version 2 as
|
|
* published by the Free Software Foundation.
|
|
*/
|
|
|
|
#include <linux/delay.h>
|
|
#include <linux/io.h>
|
|
#include <linux/module.h>
|
|
#include <linux/notifier.h>
|
|
#include <linux/of_address.h>
|
|
#include <linux/platform_device.h>
|
|
#include <linux/reboot.h>
|
|
|
|
static void __iomem *base;
|
|
static void __iomem *pcu_base;
|
|
|
|
static int zx_restart_handler(struct notifier_block *this,
|
|
unsigned long mode, void *cmd)
|
|
{
|
|
writel_relaxed(1, base + 0xb0);
|
|
writel_relaxed(1, pcu_base + 0x34);
|
|
|
|
mdelay(50);
|
|
pr_emerg("Unable to restart system\n");
|
|
|
|
return NOTIFY_DONE;
|
|
}
|
|
|
|
static struct notifier_block zx_restart_nb = {
|
|
.notifier_call = zx_restart_handler,
|
|
.priority = 128,
|
|
};
|
|
|
|
static int zx_reboot_probe(struct platform_device *pdev)
|
|
{
|
|
struct device_node *np = pdev->dev.of_node;
|
|
int err;
|
|
|
|
base = of_iomap(np, 0);
|
|
if (!base) {
|
|
WARN(1, "failed to map base address");
|
|
return -ENODEV;
|
|
}
|
|
|
|
np = of_find_compatible_node(NULL, NULL, "zte,zx296702-pcu");
|
|
pcu_base = of_iomap(np, 0);
|
|
if (!pcu_base) {
|
|
iounmap(base);
|
|
WARN(1, "failed to map pcu_base address");
|
|
return -ENODEV;
|
|
}
|
|
|
|
err = register_restart_handler(&zx_restart_nb);
|
|
if (err) {
|
|
iounmap(base);
|
|
iounmap(pcu_base);
|
|
dev_err(&pdev->dev, "Register restart handler failed(err=%d)\n",
|
|
err);
|
|
}
|
|
|
|
return err;
|
|
}
|
|
|
|
static const struct of_device_id zx_reboot_of_match[] = {
|
|
{ .compatible = "zte,sysctrl" },
|
|
{}
|
|
};
|
|
MODULE_DEVICE_TABLE(of, zx_reboot_of_match);
|
|
|
|
static struct platform_driver zx_reboot_driver = {
|
|
.probe = zx_reboot_probe,
|
|
.driver = {
|
|
.name = "zx-reboot",
|
|
.of_match_table = zx_reboot_of_match,
|
|
},
|
|
};
|
|
module_platform_driver(zx_reboot_driver);
|