structure field directly, access the sensor device instead the thermal zone's device for trace, relocate the traces in drivers/thermal (Daniel Lezcano) - Use the generic trip point for the i.MX and remove the get_trip_temp ops (Daniel Lezcano) - Use the devm_platform_ioremap_resource() in the Hisilicon driver (Yang Li) - Remove R-Car H3 ES1.* handling as public has only access to the ES2 version and the upstream support for the ES1 has been shutdown (Wolfram Sang) - Add a delay after initializing the bank in order to let the time to the hardware to initialze itself before reading the temperature (Amjad Ouled-Ameur) - Add MT8365 support (Amjad Ouled-Ameur) -----BEGIN PGP SIGNATURE----- iQEzBAABCAAdFiEEGn3N4YVz0WNVyHskqDIjiipP6E8FAmQof0cACgkQqDIjiipP 6E/tXQgArKKlM52mo3pg880JsiWOWGrS7pJN0x9MR0nqUm83sLTDf21fPoYmn+EJ wrzClIX1iHCDVCWCVxao7OIT1mxez9L2NAHseXDSDQJcZ0fflTE8wZ8xeLr6q5GN /ifHfCqiC98yejPcKIf2TqdGgqpCzyQ++sZoc3H6/jwysSkFlBc+YgKx+XasQR6k 5swQ3E81zx0ouB+t1GDieXB6YRsjZzR2KQbbExoHexPue1DTIuuumz8M1Fgz4a4b gXRHbrGp3vmLORIAOZiVDyjzC7jwy7oN552g16yZLGDUdLaJ03gRRx7fvNzDUEMW mBzxak4WnNWEatCh691X6W5MdPO/uQ== =naJV -----END PGP SIGNATURE----- Merge tag 'thermal-v6.4-rc1-1' of ssh://gitolite.kernel.org/pub/scm/linux/kernel/git/thermal/linux Pull thermal control material for 6.4-rc1 from Daniel Lezcano: "- Add more thermal zone device encapsulation: prevent setting structure field directly, access the sensor device instead the thermal zone's device for trace, relocate the traces in drivers/thermal (Daniel Lezcano) - Use the generic trip point for the i.MX and remove the get_trip_temp ops (Daniel Lezcano) - Use the devm_platform_ioremap_resource() in the Hisilicon driver (Yang Li) - Remove R-Car H3 ES1.* handling as public has only access to the ES2 version and the upstream support for the ES1 has been shutdown (Wolfram Sang) - Add a delay after initializing the bank in order to let the time to the hardware to initialze itself before reading the temperature (Amjad Ouled-Ameur) - Add MT8365 support (Amjad Ouled-Ameur)" * tag 'thermal-v6.4-rc1-1' of ssh://gitolite.kernel.org/pub/scm/linux/kernel/git/thermal/linux: thermal/drivers/ti: Use fixed update interval thermal/drivers/stm: Don't set no_hwmon to false thermal/drivers/db8500: Use driver dev instead of tz->device thermal/core: Relocate the traces definition in thermal directory thermal/drivers/hisi: Use devm_platform_ioremap_resource() thermal/drivers/imx: Use the thermal framework for the trip point thermal/drivers/imx: Remove get_trip_temp ops thermal/drivers/rcar_gen3_thermal: Remove R-Car H3 ES1.* handling thermal/drivers/mediatek: Add delay after thermal banks initialization thermal/drivers/mediatek: Add support for MT8365 SoC thermal/drivers/mediatek: Control buffer enablement tweaks dt-bindings: thermal: mediatek: Add binding documentation for MT8365 SoC
673 lines
19 KiB
C
673 lines
19 KiB
C
// SPDX-License-Identifier: GPL-2.0
|
|
/*
|
|
* linux/drivers/thermal/cpufreq_cooling.c
|
|
*
|
|
* Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com)
|
|
*
|
|
* Copyright (C) 2012-2018 Linaro Limited.
|
|
*
|
|
* Authors: Amit Daniel <amit.kachhap@linaro.org>
|
|
* Viresh Kumar <viresh.kumar@linaro.org>
|
|
*
|
|
*/
|
|
#include <linux/cpu.h>
|
|
#include <linux/cpufreq.h>
|
|
#include <linux/cpu_cooling.h>
|
|
#include <linux/device.h>
|
|
#include <linux/energy_model.h>
|
|
#include <linux/err.h>
|
|
#include <linux/export.h>
|
|
#include <linux/pm_opp.h>
|
|
#include <linux/pm_qos.h>
|
|
#include <linux/slab.h>
|
|
#include <linux/thermal.h>
|
|
#include <linux/units.h>
|
|
|
|
#include "thermal_trace.h"
|
|
|
|
/*
|
|
* Cooling state <-> CPUFreq frequency
|
|
*
|
|
* Cooling states are translated to frequencies throughout this driver and this
|
|
* is the relation between them.
|
|
*
|
|
* Highest cooling state corresponds to lowest possible frequency.
|
|
*
|
|
* i.e.
|
|
* level 0 --> 1st Max Freq
|
|
* level 1 --> 2nd Max Freq
|
|
* ...
|
|
*/
|
|
|
|
/**
|
|
* struct time_in_idle - Idle time stats
|
|
* @time: previous reading of the absolute time that this cpu was idle
|
|
* @timestamp: wall time of the last invocation of get_cpu_idle_time_us()
|
|
*/
|
|
struct time_in_idle {
|
|
u64 time;
|
|
u64 timestamp;
|
|
};
|
|
|
|
/**
|
|
* struct cpufreq_cooling_device - data for cooling device with cpufreq
|
|
* @last_load: load measured by the latest call to cpufreq_get_requested_power()
|
|
* @cpufreq_state: integer value representing the current state of cpufreq
|
|
* cooling devices.
|
|
* @max_level: maximum cooling level. One less than total number of valid
|
|
* cpufreq frequencies.
|
|
* @em: Reference on the Energy Model of the device
|
|
* @cdev: thermal_cooling_device pointer to keep track of the
|
|
* registered cooling device.
|
|
* @policy: cpufreq policy.
|
|
* @cooling_ops: cpufreq callbacks to thermal cooling device ops
|
|
* @idle_time: idle time stats
|
|
* @qos_req: PM QoS contraint to apply
|
|
*
|
|
* This structure is required for keeping information of each registered
|
|
* cpufreq_cooling_device.
|
|
*/
|
|
struct cpufreq_cooling_device {
|
|
u32 last_load;
|
|
unsigned int cpufreq_state;
|
|
unsigned int max_level;
|
|
struct em_perf_domain *em;
|
|
struct cpufreq_policy *policy;
|
|
struct thermal_cooling_device_ops cooling_ops;
|
|
#ifndef CONFIG_SMP
|
|
struct time_in_idle *idle_time;
|
|
#endif
|
|
struct freq_qos_request qos_req;
|
|
};
|
|
|
|
#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR
|
|
/**
|
|
* get_level: Find the level for a particular frequency
|
|
* @cpufreq_cdev: cpufreq_cdev for which the property is required
|
|
* @freq: Frequency
|
|
*
|
|
* Return: level corresponding to the frequency.
|
|
*/
|
|
static unsigned long get_level(struct cpufreq_cooling_device *cpufreq_cdev,
|
|
unsigned int freq)
|
|
{
|
|
int i;
|
|
|
|
for (i = cpufreq_cdev->max_level - 1; i >= 0; i--) {
|
|
if (freq > cpufreq_cdev->em->table[i].frequency)
|
|
break;
|
|
}
|
|
|
|
return cpufreq_cdev->max_level - i - 1;
|
|
}
|
|
|
|
static u32 cpu_freq_to_power(struct cpufreq_cooling_device *cpufreq_cdev,
|
|
u32 freq)
|
|
{
|
|
unsigned long power_mw;
|
|
int i;
|
|
|
|
for (i = cpufreq_cdev->max_level - 1; i >= 0; i--) {
|
|
if (freq > cpufreq_cdev->em->table[i].frequency)
|
|
break;
|
|
}
|
|
|
|
power_mw = cpufreq_cdev->em->table[i + 1].power;
|
|
power_mw /= MICROWATT_PER_MILLIWATT;
|
|
|
|
return power_mw;
|
|
}
|
|
|
|
static u32 cpu_power_to_freq(struct cpufreq_cooling_device *cpufreq_cdev,
|
|
u32 power)
|
|
{
|
|
unsigned long em_power_mw;
|
|
int i;
|
|
|
|
for (i = cpufreq_cdev->max_level; i > 0; i--) {
|
|
/* Convert EM power to milli-Watts to make safe comparison */
|
|
em_power_mw = cpufreq_cdev->em->table[i].power;
|
|
em_power_mw /= MICROWATT_PER_MILLIWATT;
|
|
if (power >= em_power_mw)
|
|
break;
|
|
}
|
|
|
|
return cpufreq_cdev->em->table[i].frequency;
|
|
}
|
|
|
|
/**
|
|
* get_load() - get load for a cpu
|
|
* @cpufreq_cdev: struct cpufreq_cooling_device for the cpu
|
|
* @cpu: cpu number
|
|
* @cpu_idx: index of the cpu in time_in_idle array
|
|
*
|
|
* Return: The average load of cpu @cpu in percentage since this
|
|
* function was last called.
|
|
*/
|
|
#ifdef CONFIG_SMP
|
|
static u32 get_load(struct cpufreq_cooling_device *cpufreq_cdev, int cpu,
|
|
int cpu_idx)
|
|
{
|
|
unsigned long util = sched_cpu_util(cpu);
|
|
|
|
return (util * 100) / arch_scale_cpu_capacity(cpu);
|
|
}
|
|
#else /* !CONFIG_SMP */
|
|
static u32 get_load(struct cpufreq_cooling_device *cpufreq_cdev, int cpu,
|
|
int cpu_idx)
|
|
{
|
|
u32 load;
|
|
u64 now, now_idle, delta_time, delta_idle;
|
|
struct time_in_idle *idle_time = &cpufreq_cdev->idle_time[cpu_idx];
|
|
|
|
now_idle = get_cpu_idle_time(cpu, &now, 0);
|
|
delta_idle = now_idle - idle_time->time;
|
|
delta_time = now - idle_time->timestamp;
|
|
|
|
if (delta_time <= delta_idle)
|
|
load = 0;
|
|
else
|
|
load = div64_u64(100 * (delta_time - delta_idle), delta_time);
|
|
|
|
idle_time->time = now_idle;
|
|
idle_time->timestamp = now;
|
|
|
|
return load;
|
|
}
|
|
#endif /* CONFIG_SMP */
|
|
|
|
/**
|
|
* get_dynamic_power() - calculate the dynamic power
|
|
* @cpufreq_cdev: &cpufreq_cooling_device for this cdev
|
|
* @freq: current frequency
|
|
*
|
|
* Return: the dynamic power consumed by the cpus described by
|
|
* @cpufreq_cdev.
|
|
*/
|
|
static u32 get_dynamic_power(struct cpufreq_cooling_device *cpufreq_cdev,
|
|
unsigned long freq)
|
|
{
|
|
u32 raw_cpu_power;
|
|
|
|
raw_cpu_power = cpu_freq_to_power(cpufreq_cdev, freq);
|
|
return (raw_cpu_power * cpufreq_cdev->last_load) / 100;
|
|
}
|
|
|
|
/**
|
|
* cpufreq_get_requested_power() - get the current power
|
|
* @cdev: &thermal_cooling_device pointer
|
|
* @power: pointer in which to store the resulting power
|
|
*
|
|
* Calculate the current power consumption of the cpus in milliwatts
|
|
* and store it in @power. This function should actually calculate
|
|
* the requested power, but it's hard to get the frequency that
|
|
* cpufreq would have assigned if there were no thermal limits.
|
|
* Instead, we calculate the current power on the assumption that the
|
|
* immediate future will look like the immediate past.
|
|
*
|
|
* We use the current frequency and the average load since this
|
|
* function was last called. In reality, there could have been
|
|
* multiple opps since this function was last called and that affects
|
|
* the load calculation. While it's not perfectly accurate, this
|
|
* simplification is good enough and works. REVISIT this, as more
|
|
* complex code may be needed if experiments show that it's not
|
|
* accurate enough.
|
|
*
|
|
* Return: 0 on success, this function doesn't fail.
|
|
*/
|
|
static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev,
|
|
u32 *power)
|
|
{
|
|
unsigned long freq;
|
|
int i = 0, cpu;
|
|
u32 total_load = 0;
|
|
struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
|
|
struct cpufreq_policy *policy = cpufreq_cdev->policy;
|
|
|
|
freq = cpufreq_quick_get(policy->cpu);
|
|
|
|
for_each_cpu(cpu, policy->related_cpus) {
|
|
u32 load;
|
|
|
|
if (cpu_online(cpu))
|
|
load = get_load(cpufreq_cdev, cpu, i);
|
|
else
|
|
load = 0;
|
|
|
|
total_load += load;
|
|
}
|
|
|
|
cpufreq_cdev->last_load = total_load;
|
|
|
|
*power = get_dynamic_power(cpufreq_cdev, freq);
|
|
|
|
trace_thermal_power_cpu_get_power_simple(policy->cpu, *power);
|
|
|
|
return 0;
|
|
}
|
|
|
|
/**
|
|
* cpufreq_state2power() - convert a cpu cdev state to power consumed
|
|
* @cdev: &thermal_cooling_device pointer
|
|
* @state: cooling device state to be converted
|
|
* @power: pointer in which to store the resulting power
|
|
*
|
|
* Convert cooling device state @state into power consumption in
|
|
* milliwatts assuming 100% load. Store the calculated power in
|
|
* @power.
|
|
*
|
|
* Return: 0 on success, -EINVAL if the cooling device state is bigger
|
|
* than maximum allowed.
|
|
*/
|
|
static int cpufreq_state2power(struct thermal_cooling_device *cdev,
|
|
unsigned long state, u32 *power)
|
|
{
|
|
unsigned int freq, num_cpus, idx;
|
|
struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
|
|
|
|
/* Request state should be less than max_level */
|
|
if (state > cpufreq_cdev->max_level)
|
|
return -EINVAL;
|
|
|
|
num_cpus = cpumask_weight(cpufreq_cdev->policy->cpus);
|
|
|
|
idx = cpufreq_cdev->max_level - state;
|
|
freq = cpufreq_cdev->em->table[idx].frequency;
|
|
*power = cpu_freq_to_power(cpufreq_cdev, freq) * num_cpus;
|
|
|
|
return 0;
|
|
}
|
|
|
|
/**
|
|
* cpufreq_power2state() - convert power to a cooling device state
|
|
* @cdev: &thermal_cooling_device pointer
|
|
* @power: power in milliwatts to be converted
|
|
* @state: pointer in which to store the resulting state
|
|
*
|
|
* Calculate a cooling device state for the cpus described by @cdev
|
|
* that would allow them to consume at most @power mW and store it in
|
|
* @state. Note that this calculation depends on external factors
|
|
* such as the CPUs load. Calling this function with the same power
|
|
* as input can yield different cooling device states depending on those
|
|
* external factors.
|
|
*
|
|
* Return: 0 on success, this function doesn't fail.
|
|
*/
|
|
static int cpufreq_power2state(struct thermal_cooling_device *cdev,
|
|
u32 power, unsigned long *state)
|
|
{
|
|
unsigned int target_freq;
|
|
u32 last_load, normalised_power;
|
|
struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
|
|
struct cpufreq_policy *policy = cpufreq_cdev->policy;
|
|
|
|
last_load = cpufreq_cdev->last_load ?: 1;
|
|
normalised_power = (power * 100) / last_load;
|
|
target_freq = cpu_power_to_freq(cpufreq_cdev, normalised_power);
|
|
|
|
*state = get_level(cpufreq_cdev, target_freq);
|
|
trace_thermal_power_cpu_limit(policy->related_cpus, target_freq, *state,
|
|
power);
|
|
return 0;
|
|
}
|
|
|
|
static inline bool em_is_sane(struct cpufreq_cooling_device *cpufreq_cdev,
|
|
struct em_perf_domain *em) {
|
|
struct cpufreq_policy *policy;
|
|
unsigned int nr_levels;
|
|
|
|
if (!em || em_is_artificial(em))
|
|
return false;
|
|
|
|
policy = cpufreq_cdev->policy;
|
|
if (!cpumask_equal(policy->related_cpus, em_span_cpus(em))) {
|
|
pr_err("The span of pd %*pbl is misaligned with cpufreq policy %*pbl\n",
|
|
cpumask_pr_args(em_span_cpus(em)),
|
|
cpumask_pr_args(policy->related_cpus));
|
|
return false;
|
|
}
|
|
|
|
nr_levels = cpufreq_cdev->max_level + 1;
|
|
if (em_pd_nr_perf_states(em) != nr_levels) {
|
|
pr_err("The number of performance states in pd %*pbl (%u) doesn't match the number of cooling levels (%u)\n",
|
|
cpumask_pr_args(em_span_cpus(em)),
|
|
em_pd_nr_perf_states(em), nr_levels);
|
|
return false;
|
|
}
|
|
|
|
return true;
|
|
}
|
|
#endif /* CONFIG_THERMAL_GOV_POWER_ALLOCATOR */
|
|
|
|
#ifdef CONFIG_SMP
|
|
static inline int allocate_idle_time(struct cpufreq_cooling_device *cpufreq_cdev)
|
|
{
|
|
return 0;
|
|
}
|
|
|
|
static inline void free_idle_time(struct cpufreq_cooling_device *cpufreq_cdev)
|
|
{
|
|
}
|
|
#else
|
|
static int allocate_idle_time(struct cpufreq_cooling_device *cpufreq_cdev)
|
|
{
|
|
unsigned int num_cpus = cpumask_weight(cpufreq_cdev->policy->related_cpus);
|
|
|
|
cpufreq_cdev->idle_time = kcalloc(num_cpus,
|
|
sizeof(*cpufreq_cdev->idle_time),
|
|
GFP_KERNEL);
|
|
if (!cpufreq_cdev->idle_time)
|
|
return -ENOMEM;
|
|
|
|
return 0;
|
|
}
|
|
|
|
static void free_idle_time(struct cpufreq_cooling_device *cpufreq_cdev)
|
|
{
|
|
kfree(cpufreq_cdev->idle_time);
|
|
cpufreq_cdev->idle_time = NULL;
|
|
}
|
|
#endif /* CONFIG_SMP */
|
|
|
|
static unsigned int get_state_freq(struct cpufreq_cooling_device *cpufreq_cdev,
|
|
unsigned long state)
|
|
{
|
|
struct cpufreq_policy *policy;
|
|
unsigned long idx;
|
|
|
|
#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR
|
|
/* Use the Energy Model table if available */
|
|
if (cpufreq_cdev->em) {
|
|
idx = cpufreq_cdev->max_level - state;
|
|
return cpufreq_cdev->em->table[idx].frequency;
|
|
}
|
|
#endif
|
|
|
|
/* Otherwise, fallback on the CPUFreq table */
|
|
policy = cpufreq_cdev->policy;
|
|
if (policy->freq_table_sorted == CPUFREQ_TABLE_SORTED_ASCENDING)
|
|
idx = cpufreq_cdev->max_level - state;
|
|
else
|
|
idx = state;
|
|
|
|
return policy->freq_table[idx].frequency;
|
|
}
|
|
|
|
/* cpufreq cooling device callback functions are defined below */
|
|
|
|
/**
|
|
* cpufreq_get_max_state - callback function to get the max cooling state.
|
|
* @cdev: thermal cooling device pointer.
|
|
* @state: fill this variable with the max cooling state.
|
|
*
|
|
* Callback for the thermal cooling device to return the cpufreq
|
|
* max cooling state.
|
|
*
|
|
* Return: 0 on success, this function doesn't fail.
|
|
*/
|
|
static int cpufreq_get_max_state(struct thermal_cooling_device *cdev,
|
|
unsigned long *state)
|
|
{
|
|
struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
|
|
|
|
*state = cpufreq_cdev->max_level;
|
|
return 0;
|
|
}
|
|
|
|
/**
|
|
* cpufreq_get_cur_state - callback function to get the current cooling state.
|
|
* @cdev: thermal cooling device pointer.
|
|
* @state: fill this variable with the current cooling state.
|
|
*
|
|
* Callback for the thermal cooling device to return the cpufreq
|
|
* current cooling state.
|
|
*
|
|
* Return: 0 on success, this function doesn't fail.
|
|
*/
|
|
static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
|
|
unsigned long *state)
|
|
{
|
|
struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
|
|
|
|
*state = cpufreq_cdev->cpufreq_state;
|
|
|
|
return 0;
|
|
}
|
|
|
|
/**
|
|
* cpufreq_set_cur_state - callback function to set the current cooling state.
|
|
* @cdev: thermal cooling device pointer.
|
|
* @state: set this variable to the current cooling state.
|
|
*
|
|
* Callback for the thermal cooling device to change the cpufreq
|
|
* current cooling state.
|
|
*
|
|
* Return: 0 on success, an error code otherwise.
|
|
*/
|
|
static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
|
|
unsigned long state)
|
|
{
|
|
struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
|
|
struct cpumask *cpus;
|
|
unsigned int frequency;
|
|
int ret;
|
|
|
|
/* Request state should be less than max_level */
|
|
if (state > cpufreq_cdev->max_level)
|
|
return -EINVAL;
|
|
|
|
/* Check if the old cooling action is same as new cooling action */
|
|
if (cpufreq_cdev->cpufreq_state == state)
|
|
return 0;
|
|
|
|
frequency = get_state_freq(cpufreq_cdev, state);
|
|
|
|
ret = freq_qos_update_request(&cpufreq_cdev->qos_req, frequency);
|
|
if (ret >= 0) {
|
|
cpufreq_cdev->cpufreq_state = state;
|
|
cpus = cpufreq_cdev->policy->related_cpus;
|
|
arch_update_thermal_pressure(cpus, frequency);
|
|
ret = 0;
|
|
}
|
|
|
|
return ret;
|
|
}
|
|
|
|
/**
|
|
* __cpufreq_cooling_register - helper function to create cpufreq cooling device
|
|
* @np: a valid struct device_node to the cooling device tree node
|
|
* @policy: cpufreq policy
|
|
* Normally this should be same as cpufreq policy->related_cpus.
|
|
* @em: Energy Model of the cpufreq policy
|
|
*
|
|
* This interface function registers the cpufreq cooling device with the name
|
|
* "cpufreq-%s". This API can support multiple instances of cpufreq
|
|
* cooling devices. It also gives the opportunity to link the cooling device
|
|
* with a device tree node, in order to bind it via the thermal DT code.
|
|
*
|
|
* Return: a valid struct thermal_cooling_device pointer on success,
|
|
* on failure, it returns a corresponding ERR_PTR().
|
|
*/
|
|
static struct thermal_cooling_device *
|
|
__cpufreq_cooling_register(struct device_node *np,
|
|
struct cpufreq_policy *policy,
|
|
struct em_perf_domain *em)
|
|
{
|
|
struct thermal_cooling_device *cdev;
|
|
struct cpufreq_cooling_device *cpufreq_cdev;
|
|
unsigned int i;
|
|
struct device *dev;
|
|
int ret;
|
|
struct thermal_cooling_device_ops *cooling_ops;
|
|
char *name;
|
|
|
|
if (IS_ERR_OR_NULL(policy)) {
|
|
pr_err("%s: cpufreq policy isn't valid: %p\n", __func__, policy);
|
|
return ERR_PTR(-EINVAL);
|
|
}
|
|
|
|
dev = get_cpu_device(policy->cpu);
|
|
if (unlikely(!dev)) {
|
|
pr_warn("No cpu device for cpu %d\n", policy->cpu);
|
|
return ERR_PTR(-ENODEV);
|
|
}
|
|
|
|
i = cpufreq_table_count_valid_entries(policy);
|
|
if (!i) {
|
|
pr_debug("%s: CPUFreq table not found or has no valid entries\n",
|
|
__func__);
|
|
return ERR_PTR(-ENODEV);
|
|
}
|
|
|
|
cpufreq_cdev = kzalloc(sizeof(*cpufreq_cdev), GFP_KERNEL);
|
|
if (!cpufreq_cdev)
|
|
return ERR_PTR(-ENOMEM);
|
|
|
|
cpufreq_cdev->policy = policy;
|
|
|
|
ret = allocate_idle_time(cpufreq_cdev);
|
|
if (ret) {
|
|
cdev = ERR_PTR(ret);
|
|
goto free_cdev;
|
|
}
|
|
|
|
/* max_level is an index, not a counter */
|
|
cpufreq_cdev->max_level = i - 1;
|
|
|
|
cooling_ops = &cpufreq_cdev->cooling_ops;
|
|
cooling_ops->get_max_state = cpufreq_get_max_state;
|
|
cooling_ops->get_cur_state = cpufreq_get_cur_state;
|
|
cooling_ops->set_cur_state = cpufreq_set_cur_state;
|
|
|
|
#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR
|
|
if (em_is_sane(cpufreq_cdev, em)) {
|
|
cpufreq_cdev->em = em;
|
|
cooling_ops->get_requested_power = cpufreq_get_requested_power;
|
|
cooling_ops->state2power = cpufreq_state2power;
|
|
cooling_ops->power2state = cpufreq_power2state;
|
|
} else
|
|
#endif
|
|
if (policy->freq_table_sorted == CPUFREQ_TABLE_UNSORTED) {
|
|
pr_err("%s: unsorted frequency tables are not supported\n",
|
|
__func__);
|
|
cdev = ERR_PTR(-EINVAL);
|
|
goto free_idle_time;
|
|
}
|
|
|
|
ret = freq_qos_add_request(&policy->constraints,
|
|
&cpufreq_cdev->qos_req, FREQ_QOS_MAX,
|
|
get_state_freq(cpufreq_cdev, 0));
|
|
if (ret < 0) {
|
|
pr_err("%s: Failed to add freq constraint (%d)\n", __func__,
|
|
ret);
|
|
cdev = ERR_PTR(ret);
|
|
goto free_idle_time;
|
|
}
|
|
|
|
cdev = ERR_PTR(-ENOMEM);
|
|
name = kasprintf(GFP_KERNEL, "cpufreq-%s", dev_name(dev));
|
|
if (!name)
|
|
goto remove_qos_req;
|
|
|
|
cdev = thermal_of_cooling_device_register(np, name, cpufreq_cdev,
|
|
cooling_ops);
|
|
kfree(name);
|
|
|
|
if (IS_ERR(cdev))
|
|
goto remove_qos_req;
|
|
|
|
return cdev;
|
|
|
|
remove_qos_req:
|
|
freq_qos_remove_request(&cpufreq_cdev->qos_req);
|
|
free_idle_time:
|
|
free_idle_time(cpufreq_cdev);
|
|
free_cdev:
|
|
kfree(cpufreq_cdev);
|
|
return cdev;
|
|
}
|
|
|
|
/**
|
|
* cpufreq_cooling_register - function to create cpufreq cooling device.
|
|
* @policy: cpufreq policy
|
|
*
|
|
* This interface function registers the cpufreq cooling device with the name
|
|
* "cpufreq-%s". This API can support multiple instances of cpufreq cooling
|
|
* devices.
|
|
*
|
|
* Return: a valid struct thermal_cooling_device pointer on success,
|
|
* on failure, it returns a corresponding ERR_PTR().
|
|
*/
|
|
struct thermal_cooling_device *
|
|
cpufreq_cooling_register(struct cpufreq_policy *policy)
|
|
{
|
|
return __cpufreq_cooling_register(NULL, policy, NULL);
|
|
}
|
|
EXPORT_SYMBOL_GPL(cpufreq_cooling_register);
|
|
|
|
/**
|
|
* of_cpufreq_cooling_register - function to create cpufreq cooling device.
|
|
* @policy: cpufreq policy
|
|
*
|
|
* This interface function registers the cpufreq cooling device with the name
|
|
* "cpufreq-%s". This API can support multiple instances of cpufreq cooling
|
|
* devices. Using this API, the cpufreq cooling device will be linked to the
|
|
* device tree node provided.
|
|
*
|
|
* Using this function, the cooling device will implement the power
|
|
* extensions by using the Energy Model (if present). The cpus must have
|
|
* registered their OPPs using the OPP library.
|
|
*
|
|
* Return: a valid struct thermal_cooling_device pointer on success,
|
|
* and NULL on failure.
|
|
*/
|
|
struct thermal_cooling_device *
|
|
of_cpufreq_cooling_register(struct cpufreq_policy *policy)
|
|
{
|
|
struct device_node *np = of_get_cpu_node(policy->cpu, NULL);
|
|
struct thermal_cooling_device *cdev = NULL;
|
|
|
|
if (!np) {
|
|
pr_err("cpufreq_cooling: OF node not available for cpu%d\n",
|
|
policy->cpu);
|
|
return NULL;
|
|
}
|
|
|
|
if (of_property_present(np, "#cooling-cells")) {
|
|
struct em_perf_domain *em = em_cpu_get(policy->cpu);
|
|
|
|
cdev = __cpufreq_cooling_register(np, policy, em);
|
|
if (IS_ERR(cdev)) {
|
|
pr_err("cpufreq_cooling: cpu%d failed to register as cooling device: %ld\n",
|
|
policy->cpu, PTR_ERR(cdev));
|
|
cdev = NULL;
|
|
}
|
|
}
|
|
|
|
of_node_put(np);
|
|
return cdev;
|
|
}
|
|
EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register);
|
|
|
|
/**
|
|
* cpufreq_cooling_unregister - function to remove cpufreq cooling device.
|
|
* @cdev: thermal cooling device pointer.
|
|
*
|
|
* This interface function unregisters the "cpufreq-%x" cooling device.
|
|
*/
|
|
void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
|
|
{
|
|
struct cpufreq_cooling_device *cpufreq_cdev;
|
|
|
|
if (!cdev)
|
|
return;
|
|
|
|
cpufreq_cdev = cdev->devdata;
|
|
|
|
thermal_cooling_device_unregister(cdev);
|
|
freq_qos_remove_request(&cpufreq_cdev->qos_req);
|
|
free_idle_time(cpufreq_cdev);
|
|
kfree(cpufreq_cdev);
|
|
}
|
|
EXPORT_SYMBOL_GPL(cpufreq_cooling_unregister);
|