This patch implements LED driver for PowerNV platform using the existing generic LED class framework. PowerNV platform has below type of LEDs: - System attention Indicates there is a problem with the system that needs attention. - Identify Helps the user locate/identify a particular FRU or resource in the system. - Fault Indicates there is a problem with the FRU or resource at the location with which the indicator is associated. We register classdev structures for all individual LEDs detected on the system through LED specific device tree nodes. Device tree nodes specify what all kind of LEDs present on the same location code. It registers LED classdev structure for each of them. All the system LEDs can be found in the same regular path /sys/class/leds/. We don't use LED colors. We use LED node and led-types property to form LED classdev. Our LEDs have names in this format. <location_code>:<attention|identify|fault> Any positive brightness value would turn on the LED and a zero value would turn off the LED. The driver will return LED_FULL (255) for any turned on LED and LED_OFF (0) for any turned off LED. The platform level implementation of LED get and set state has been achieved through OPAL calls. These calls are made available for the driver by exporting from architecture specific codes. Signed-off-by: Vasant Hegde <hegdevasant@linux.vnet.ibm.com> Signed-off-by: Anshuman Khandual <khandual@linux.vnet.ibm.com> Acked-by: Stewart Smith <stewart@linux.vnet.ibm.com> Tested-by: Stewart Smith <stewart@linux.vnet.ibm.com> Acked-by: Jacek Anaszewski <j.anaszewski@samsung.com> Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
27 lines
613 B
Plaintext
27 lines
613 B
Plaintext
Device Tree binding for LEDs on IBM Power Systems
|
|
-------------------------------------------------
|
|
|
|
Required properties:
|
|
- compatible : Should be "ibm,opal-v3-led".
|
|
- led-mode : Should be "lightpath" or "guidinglight".
|
|
|
|
Each location code of FRU/Enclosure must be expressed in the
|
|
form of a sub-node.
|
|
|
|
Required properties for the sub nodes:
|
|
- led-types : Supported LED types (attention/identify/fault) provided
|
|
in the form of string array.
|
|
|
|
Example:
|
|
|
|
leds {
|
|
compatible = "ibm,opal-v3-led";
|
|
led-mode = "lightpath";
|
|
|
|
U78C9.001.RST0027-P1-C1 {
|
|
led-types = "identify", "fault";
|
|
};
|
|
...
|
|
...
|
|
};
|