This prevents use of this driver with ACPI via PRP0001 and is an example of an anti pattern I'm trying to remove from IIO. Hence drop from this driver. Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com> Cc: David Barksdale <dbarksdale@uplogix.com> Link: https://lore.kernel.org/r/20200910173242.621168-38-jic23@kernel.org
167 lines
4.4 KiB
C
167 lines
4.4 KiB
C
// SPDX-License-Identifier: GPL-2.0-only
|
|
/*
|
|
* si7020.c - Silicon Labs Si7013/20/21 Relative Humidity and Temp Sensors
|
|
* Copyright (c) 2013,2014 Uplogix, Inc.
|
|
* David Barksdale <dbarksdale@uplogix.com>
|
|
*/
|
|
|
|
/*
|
|
* The Silicon Labs Si7013/20/21 Relative Humidity and Temperature Sensors
|
|
* are i2c devices which have an identical programming interface for
|
|
* measuring relative humidity and temperature. The Si7013 has an additional
|
|
* temperature input which this driver does not support.
|
|
*
|
|
* Data Sheets:
|
|
* Si7013: http://www.silabs.com/Support%20Documents/TechnicalDocs/Si7013.pdf
|
|
* Si7020: http://www.silabs.com/Support%20Documents/TechnicalDocs/Si7020.pdf
|
|
* Si7021: http://www.silabs.com/Support%20Documents/TechnicalDocs/Si7021.pdf
|
|
*/
|
|
|
|
#include <linux/delay.h>
|
|
#include <linux/i2c.h>
|
|
#include <linux/module.h>
|
|
#include <linux/mod_devicetable.h>
|
|
#include <linux/slab.h>
|
|
#include <linux/sysfs.h>
|
|
|
|
#include <linux/iio/iio.h>
|
|
#include <linux/iio/sysfs.h>
|
|
|
|
/* Measure Relative Humidity, Hold Master Mode */
|
|
#define SI7020CMD_RH_HOLD 0xE5
|
|
/* Measure Temperature, Hold Master Mode */
|
|
#define SI7020CMD_TEMP_HOLD 0xE3
|
|
/* Software Reset */
|
|
#define SI7020CMD_RESET 0xFE
|
|
|
|
static int si7020_read_raw(struct iio_dev *indio_dev,
|
|
struct iio_chan_spec const *chan, int *val,
|
|
int *val2, long mask)
|
|
{
|
|
struct i2c_client **client = iio_priv(indio_dev);
|
|
int ret;
|
|
|
|
switch (mask) {
|
|
case IIO_CHAN_INFO_RAW:
|
|
ret = i2c_smbus_read_word_swapped(*client,
|
|
chan->type == IIO_TEMP ?
|
|
SI7020CMD_TEMP_HOLD :
|
|
SI7020CMD_RH_HOLD);
|
|
if (ret < 0)
|
|
return ret;
|
|
*val = ret >> 2;
|
|
/*
|
|
* Humidity values can slightly exceed the 0-100%RH
|
|
* range and should be corrected by software
|
|
*/
|
|
if (chan->type == IIO_HUMIDITYRELATIVE)
|
|
*val = clamp_val(*val, 786, 13893);
|
|
return IIO_VAL_INT;
|
|
case IIO_CHAN_INFO_SCALE:
|
|
if (chan->type == IIO_TEMP)
|
|
*val = 175720; /* = 175.72 * 1000 */
|
|
else
|
|
*val = 125 * 1000;
|
|
*val2 = 65536 >> 2;
|
|
return IIO_VAL_FRACTIONAL;
|
|
case IIO_CHAN_INFO_OFFSET:
|
|
/*
|
|
* Since iio_convert_raw_to_processed_unlocked assumes offset
|
|
* is an integer we have to round these values and lose
|
|
* accuracy.
|
|
* Relative humidity will be 0.0032959% too high and
|
|
* temperature will be 0.00277344 degrees too high.
|
|
* This is no big deal because it's within the accuracy of the
|
|
* sensor.
|
|
*/
|
|
if (chan->type == IIO_TEMP)
|
|
*val = -4368; /* = -46.85 * (65536 >> 2) / 175.72 */
|
|
else
|
|
*val = -786; /* = -6 * (65536 >> 2) / 125 */
|
|
return IIO_VAL_INT;
|
|
default:
|
|
break;
|
|
}
|
|
|
|
return -EINVAL;
|
|
}
|
|
|
|
static const struct iio_chan_spec si7020_channels[] = {
|
|
{
|
|
.type = IIO_HUMIDITYRELATIVE,
|
|
.info_mask_separate = BIT(IIO_CHAN_INFO_RAW) |
|
|
BIT(IIO_CHAN_INFO_SCALE) | BIT(IIO_CHAN_INFO_OFFSET),
|
|
},
|
|
{
|
|
.type = IIO_TEMP,
|
|
.info_mask_separate = BIT(IIO_CHAN_INFO_RAW) |
|
|
BIT(IIO_CHAN_INFO_SCALE) | BIT(IIO_CHAN_INFO_OFFSET),
|
|
}
|
|
};
|
|
|
|
static const struct iio_info si7020_info = {
|
|
.read_raw = si7020_read_raw,
|
|
};
|
|
|
|
static int si7020_probe(struct i2c_client *client,
|
|
const struct i2c_device_id *id)
|
|
{
|
|
struct iio_dev *indio_dev;
|
|
struct i2c_client **data;
|
|
int ret;
|
|
|
|
if (!i2c_check_functionality(client->adapter,
|
|
I2C_FUNC_SMBUS_WRITE_BYTE |
|
|
I2C_FUNC_SMBUS_READ_WORD_DATA))
|
|
return -EOPNOTSUPP;
|
|
|
|
/* Reset device, loads default settings. */
|
|
ret = i2c_smbus_write_byte(client, SI7020CMD_RESET);
|
|
if (ret < 0)
|
|
return ret;
|
|
/* Wait the maximum power-up time after software reset. */
|
|
msleep(15);
|
|
|
|
indio_dev = devm_iio_device_alloc(&client->dev, sizeof(*data));
|
|
if (!indio_dev)
|
|
return -ENOMEM;
|
|
|
|
data = iio_priv(indio_dev);
|
|
*data = client;
|
|
|
|
indio_dev->name = dev_name(&client->dev);
|
|
indio_dev->modes = INDIO_DIRECT_MODE;
|
|
indio_dev->info = &si7020_info;
|
|
indio_dev->channels = si7020_channels;
|
|
indio_dev->num_channels = ARRAY_SIZE(si7020_channels);
|
|
|
|
return devm_iio_device_register(&client->dev, indio_dev);
|
|
}
|
|
|
|
static const struct i2c_device_id si7020_id[] = {
|
|
{ "si7020", 0 },
|
|
{ "th06", 0 },
|
|
{ }
|
|
};
|
|
MODULE_DEVICE_TABLE(i2c, si7020_id);
|
|
|
|
static const struct of_device_id si7020_dt_ids[] = {
|
|
{ .compatible = "silabs,si7020" },
|
|
{ }
|
|
};
|
|
MODULE_DEVICE_TABLE(of, si7020_dt_ids);
|
|
|
|
static struct i2c_driver si7020_driver = {
|
|
.driver = {
|
|
.name = "si7020",
|
|
.of_match_table = si7020_dt_ids,
|
|
},
|
|
.probe = si7020_probe,
|
|
.id_table = si7020_id,
|
|
};
|
|
|
|
module_i2c_driver(si7020_driver);
|
|
MODULE_DESCRIPTION("Silicon Labs Si7013/20/21 Relative Humidity and Temperature Sensors");
|
|
MODULE_AUTHOR("David Barksdale <dbarksdale@uplogix.com>");
|
|
MODULE_LICENSE("GPL");
|