linux/tools/thermal/tmon
Brian Norris 986ffe0384 tools/thermal: tmon: silence 'set but not used' warnings
gcc complains about the 'cols' variable being unused. This is
unavoidable, given the ncurses getmaxyx() macro-based API, which wants
to assign to a variable directly, even when we're not going to use it.

Warning:

    gcc -O1 -Wall -Wshadow -W -Wformat -Wimplicit-function-declaration -Wimplicit-int -fstack-protector -D VERSION=\"1.0\"   -c -o tui.o tui.c
    tui.c: In function ‘show_dialogue’:
    tui.c:288:12: warning: variable ‘cols’ set but not used [-Wunused-but-set-variable]
      int rows, cols;
                ^

So, add a hack to get rid of that warning.

Signed-off-by: Brian Norris <computersforpeace@gmail.com>
Acked-by: Jacob Pan <jacob.jun.pan@linux.intel.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2015-02-28 13:52:48 +08:00
..
.gitignore tools/thermal: tmon: add .gitignore 2015-02-28 13:52:47 +08:00
Makefile tools/thermal: tmon: use pkg-config to determine library dependencies 2015-02-28 13:52:48 +08:00
pid.c
README
sysfs.c calloc/xcalloc: Fix argument order 2014-12-09 10:06:29 -03:00
tmon.8 tools/thermal: tmon: add --target-temp parameter 2015-02-28 13:52:47 +08:00
tmon.c tools/thermal: tmon: add --target-temp parameter 2015-02-28 13:52:47 +08:00
tmon.h
tui.c tools/thermal: tmon: silence 'set but not used' warnings 2015-02-28 13:52:48 +08:00

TMON - A Monitoring and Testing Tool for Linux kernel thermal subsystem

Why TMON?
==========
Increasingly, Linux is running on thermally constrained devices. The simple
thermal relationship between processor and fan has become past for modern
computers.

As hardware vendors cope with the thermal constraints on their products, more
and more sensors are added, new cooling capabilities are introduced. The
complexity of the thermal relationship can grow exponentially among cooling
devices, zones, sensors, and trip points. They can also change dynamically.

To expose such relationship to the userspace, Linux generic thermal layer
introduced sysfs entry at /sys/class/thermal with a matrix of symbolic
links, trip point bindings, and device instances. To traverse such
matrix by hand is not a trivial task. Testing is also difficult in that
thermal conditions are often exception cases that hard to reach in
normal operations.

TMON is conceived as a tool to help visualize, tune, and test the
complex thermal subsystem.

Files
=====
	tmon.c : main function for set up and configurations.
	tui.c : handles ncurses based user interface
	sysfs.c : access to the generic thermal sysfs
	pid.c : a proportional-integral-derivative (PID) controller
	that can be used for thermal relationship training.

Requirements
============
Depends on ncurses

Build
=========
$ make
$ sudo ./tmon -h
Usage: tmon [OPTION...]
  -c, --control         cooling device in control
  -d, --daemon          run as daemon, no TUI
  -l, --log             log data to /var/tmp/tmon.log
  -h, --help            show this help message
  -t, --time-interval   set time interval for sampling
  -v, --version         show version
  -g, --debug           debug message in syslog

1. For monitoring only:
$ sudo ./tmon