mirror of
https://github.com/torvalds/linux.git
synced 2024-12-29 14:21:47 +00:00
eec40579d8
dm-era is a target that behaves similar to the linear target. In addition it keeps track of which blocks were written within a user defined period of time called an 'era'. Each era target instance maintains the current era as a monotonically increasing 32-bit counter. Use cases include tracking changed blocks for backup software, and partially invalidating the contents of a cache to restore cache coherency after rolling back a vendor snapshot. dm-era is primarily expected to be paired with the dm-cache target. Signed-off-by: Joe Thornber <ejt@redhat.com> Signed-off-by: Mike Snitzer <snitzer@redhat.com>
436 lines
14 KiB
Plaintext
436 lines
14 KiB
Plaintext
#
|
|
# Block device driver configuration
|
|
#
|
|
|
|
menuconfig MD
|
|
bool "Multiple devices driver support (RAID and LVM)"
|
|
depends on BLOCK
|
|
help
|
|
Support multiple physical spindles through a single logical device.
|
|
Required for RAID and logical volume management.
|
|
|
|
if MD
|
|
|
|
config BLK_DEV_MD
|
|
tristate "RAID support"
|
|
---help---
|
|
This driver lets you combine several hard disk partitions into one
|
|
logical block device. This can be used to simply append one
|
|
partition to another one or to combine several redundant hard disks
|
|
into a RAID1/4/5 device so as to provide protection against hard
|
|
disk failures. This is called "Software RAID" since the combining of
|
|
the partitions is done by the kernel. "Hardware RAID" means that the
|
|
combining is done by a dedicated controller; if you have such a
|
|
controller, you do not need to say Y here.
|
|
|
|
More information about Software RAID on Linux is contained in the
|
|
Software RAID mini-HOWTO, available from
|
|
<http://www.tldp.org/docs.html#howto>. There you will also learn
|
|
where to get the supporting user space utilities raidtools.
|
|
|
|
If unsure, say N.
|
|
|
|
config MD_AUTODETECT
|
|
bool "Autodetect RAID arrays during kernel boot"
|
|
depends on BLK_DEV_MD=y
|
|
default y
|
|
---help---
|
|
If you say Y here, then the kernel will try to autodetect raid
|
|
arrays as part of its boot process.
|
|
|
|
If you don't use raid and say Y, this autodetection can cause
|
|
a several-second delay in the boot time due to various
|
|
synchronisation steps that are part of this step.
|
|
|
|
If unsure, say Y.
|
|
|
|
config MD_LINEAR
|
|
tristate "Linear (append) mode"
|
|
depends on BLK_DEV_MD
|
|
---help---
|
|
If you say Y here, then your multiple devices driver will be able to
|
|
use the so-called linear mode, i.e. it will combine the hard disk
|
|
partitions by simply appending one to the other.
|
|
|
|
To compile this as a module, choose M here: the module
|
|
will be called linear.
|
|
|
|
If unsure, say Y.
|
|
|
|
config MD_RAID0
|
|
tristate "RAID-0 (striping) mode"
|
|
depends on BLK_DEV_MD
|
|
---help---
|
|
If you say Y here, then your multiple devices driver will be able to
|
|
use the so-called raid0 mode, i.e. it will combine the hard disk
|
|
partitions into one logical device in such a fashion as to fill them
|
|
up evenly, one chunk here and one chunk there. This will increase
|
|
the throughput rate if the partitions reside on distinct disks.
|
|
|
|
Information about Software RAID on Linux is contained in the
|
|
Software-RAID mini-HOWTO, available from
|
|
<http://www.tldp.org/docs.html#howto>. There you will also
|
|
learn where to get the supporting user space utilities raidtools.
|
|
|
|
To compile this as a module, choose M here: the module
|
|
will be called raid0.
|
|
|
|
If unsure, say Y.
|
|
|
|
config MD_RAID1
|
|
tristate "RAID-1 (mirroring) mode"
|
|
depends on BLK_DEV_MD
|
|
---help---
|
|
A RAID-1 set consists of several disk drives which are exact copies
|
|
of each other. In the event of a mirror failure, the RAID driver
|
|
will continue to use the operational mirrors in the set, providing
|
|
an error free MD (multiple device) to the higher levels of the
|
|
kernel. In a set with N drives, the available space is the capacity
|
|
of a single drive, and the set protects against a failure of (N - 1)
|
|
drives.
|
|
|
|
Information about Software RAID on Linux is contained in the
|
|
Software-RAID mini-HOWTO, available from
|
|
<http://www.tldp.org/docs.html#howto>. There you will also
|
|
learn where to get the supporting user space utilities raidtools.
|
|
|
|
If you want to use such a RAID-1 set, say Y. To compile this code
|
|
as a module, choose M here: the module will be called raid1.
|
|
|
|
If unsure, say Y.
|
|
|
|
config MD_RAID10
|
|
tristate "RAID-10 (mirrored striping) mode"
|
|
depends on BLK_DEV_MD
|
|
---help---
|
|
RAID-10 provides a combination of striping (RAID-0) and
|
|
mirroring (RAID-1) with easier configuration and more flexible
|
|
layout.
|
|
Unlike RAID-0, but like RAID-1, RAID-10 requires all devices to
|
|
be the same size (or at least, only as much as the smallest device
|
|
will be used).
|
|
RAID-10 provides a variety of layouts that provide different levels
|
|
of redundancy and performance.
|
|
|
|
RAID-10 requires mdadm-1.7.0 or later, available at:
|
|
|
|
ftp://ftp.kernel.org/pub/linux/utils/raid/mdadm/
|
|
|
|
If unsure, say Y.
|
|
|
|
config MD_RAID456
|
|
tristate "RAID-4/RAID-5/RAID-6 mode"
|
|
depends on BLK_DEV_MD
|
|
select RAID6_PQ
|
|
select ASYNC_MEMCPY
|
|
select ASYNC_XOR
|
|
select ASYNC_PQ
|
|
select ASYNC_RAID6_RECOV
|
|
---help---
|
|
A RAID-5 set of N drives with a capacity of C MB per drive provides
|
|
the capacity of C * (N - 1) MB, and protects against a failure
|
|
of a single drive. For a given sector (row) number, (N - 1) drives
|
|
contain data sectors, and one drive contains the parity protection.
|
|
For a RAID-4 set, the parity blocks are present on a single drive,
|
|
while a RAID-5 set distributes the parity across the drives in one
|
|
of the available parity distribution methods.
|
|
|
|
A RAID-6 set of N drives with a capacity of C MB per drive
|
|
provides the capacity of C * (N - 2) MB, and protects
|
|
against a failure of any two drives. For a given sector
|
|
(row) number, (N - 2) drives contain data sectors, and two
|
|
drives contains two independent redundancy syndromes. Like
|
|
RAID-5, RAID-6 distributes the syndromes across the drives
|
|
in one of the available parity distribution methods.
|
|
|
|
Information about Software RAID on Linux is contained in the
|
|
Software-RAID mini-HOWTO, available from
|
|
<http://www.tldp.org/docs.html#howto>. There you will also
|
|
learn where to get the supporting user space utilities raidtools.
|
|
|
|
If you want to use such a RAID-4/RAID-5/RAID-6 set, say Y. To
|
|
compile this code as a module, choose M here: the module
|
|
will be called raid456.
|
|
|
|
If unsure, say Y.
|
|
|
|
config MD_MULTIPATH
|
|
tristate "Multipath I/O support"
|
|
depends on BLK_DEV_MD
|
|
help
|
|
MD_MULTIPATH provides a simple multi-path personality for use
|
|
the MD framework. It is not under active development. New
|
|
projects should consider using DM_MULTIPATH which has more
|
|
features and more testing.
|
|
|
|
If unsure, say N.
|
|
|
|
config MD_FAULTY
|
|
tristate "Faulty test module for MD"
|
|
depends on BLK_DEV_MD
|
|
help
|
|
The "faulty" module allows for a block device that occasionally returns
|
|
read or write errors. It is useful for testing.
|
|
|
|
In unsure, say N.
|
|
|
|
source "drivers/md/bcache/Kconfig"
|
|
|
|
config BLK_DEV_DM_BUILTIN
|
|
boolean
|
|
|
|
config BLK_DEV_DM
|
|
tristate "Device mapper support"
|
|
select BLK_DEV_DM_BUILTIN
|
|
---help---
|
|
Device-mapper is a low level volume manager. It works by allowing
|
|
people to specify mappings for ranges of logical sectors. Various
|
|
mapping types are available, in addition people may write their own
|
|
modules containing custom mappings if they wish.
|
|
|
|
Higher level volume managers such as LVM2 use this driver.
|
|
|
|
To compile this as a module, choose M here: the module will be
|
|
called dm-mod.
|
|
|
|
If unsure, say N.
|
|
|
|
config DM_DEBUG
|
|
boolean "Device mapper debugging support"
|
|
depends on BLK_DEV_DM
|
|
---help---
|
|
Enable this for messages that may help debug device-mapper problems.
|
|
|
|
If unsure, say N.
|
|
|
|
config DM_BUFIO
|
|
tristate
|
|
depends on BLK_DEV_DM
|
|
---help---
|
|
This interface allows you to do buffered I/O on a device and acts
|
|
as a cache, holding recently-read blocks in memory and performing
|
|
delayed writes.
|
|
|
|
config DM_BIO_PRISON
|
|
tristate
|
|
depends on BLK_DEV_DM
|
|
---help---
|
|
Some bio locking schemes used by other device-mapper targets
|
|
including thin provisioning.
|
|
|
|
source "drivers/md/persistent-data/Kconfig"
|
|
|
|
config DM_CRYPT
|
|
tristate "Crypt target support"
|
|
depends on BLK_DEV_DM
|
|
select CRYPTO
|
|
select CRYPTO_CBC
|
|
---help---
|
|
This device-mapper target allows you to create a device that
|
|
transparently encrypts the data on it. You'll need to activate
|
|
the ciphers you're going to use in the cryptoapi configuration.
|
|
|
|
Information on how to use dm-crypt can be found on
|
|
|
|
<http://www.saout.de/misc/dm-crypt/>
|
|
|
|
To compile this code as a module, choose M here: the module will
|
|
be called dm-crypt.
|
|
|
|
If unsure, say N.
|
|
|
|
config DM_SNAPSHOT
|
|
tristate "Snapshot target"
|
|
depends on BLK_DEV_DM
|
|
select DM_BUFIO
|
|
---help---
|
|
Allow volume managers to take writable snapshots of a device.
|
|
|
|
config DM_THIN_PROVISIONING
|
|
tristate "Thin provisioning target"
|
|
depends on BLK_DEV_DM
|
|
select DM_PERSISTENT_DATA
|
|
select DM_BIO_PRISON
|
|
---help---
|
|
Provides thin provisioning and snapshots that share a data store.
|
|
|
|
config DM_CACHE
|
|
tristate "Cache target (EXPERIMENTAL)"
|
|
depends on BLK_DEV_DM
|
|
default n
|
|
select DM_PERSISTENT_DATA
|
|
select DM_BIO_PRISON
|
|
---help---
|
|
dm-cache attempts to improve performance of a block device by
|
|
moving frequently used data to a smaller, higher performance
|
|
device. Different 'policy' plugins can be used to change the
|
|
algorithms used to select which blocks are promoted, demoted,
|
|
cleaned etc. It supports writeback and writethrough modes.
|
|
|
|
config DM_CACHE_MQ
|
|
tristate "MQ Cache Policy (EXPERIMENTAL)"
|
|
depends on DM_CACHE
|
|
default y
|
|
---help---
|
|
A cache policy that uses a multiqueue ordered by recent hit
|
|
count to select which blocks should be promoted and demoted.
|
|
This is meant to be a general purpose policy. It prioritises
|
|
reads over writes.
|
|
|
|
config DM_CACHE_CLEANER
|
|
tristate "Cleaner Cache Policy (EXPERIMENTAL)"
|
|
depends on DM_CACHE
|
|
default y
|
|
---help---
|
|
A simple cache policy that writes back all data to the
|
|
origin. Used when decommissioning a dm-cache.
|
|
|
|
config DM_ERA
|
|
tristate "Era target (EXPERIMENTAL)"
|
|
depends on BLK_DEV_DM
|
|
default n
|
|
select DM_PERSISTENT_DATA
|
|
select DM_BIO_PRISON
|
|
---help---
|
|
dm-era tracks which parts of a block device are written to
|
|
over time. Useful for maintaining cache coherency when using
|
|
vendor snapshots.
|
|
|
|
config DM_MIRROR
|
|
tristate "Mirror target"
|
|
depends on BLK_DEV_DM
|
|
---help---
|
|
Allow volume managers to mirror logical volumes, also
|
|
needed for live data migration tools such as 'pvmove'.
|
|
|
|
config DM_LOG_USERSPACE
|
|
tristate "Mirror userspace logging"
|
|
depends on DM_MIRROR && NET
|
|
select CONNECTOR
|
|
---help---
|
|
The userspace logging module provides a mechanism for
|
|
relaying the dm-dirty-log API to userspace. Log designs
|
|
which are more suited to userspace implementation (e.g.
|
|
shared storage logs) or experimental logs can be implemented
|
|
by leveraging this framework.
|
|
|
|
config DM_RAID
|
|
tristate "RAID 1/4/5/6/10 target"
|
|
depends on BLK_DEV_DM
|
|
select MD_RAID1
|
|
select MD_RAID10
|
|
select MD_RAID456
|
|
select BLK_DEV_MD
|
|
---help---
|
|
A dm target that supports RAID1, RAID10, RAID4, RAID5 and RAID6 mappings
|
|
|
|
A RAID-5 set of N drives with a capacity of C MB per drive provides
|
|
the capacity of C * (N - 1) MB, and protects against a failure
|
|
of a single drive. For a given sector (row) number, (N - 1) drives
|
|
contain data sectors, and one drive contains the parity protection.
|
|
For a RAID-4 set, the parity blocks are present on a single drive,
|
|
while a RAID-5 set distributes the parity across the drives in one
|
|
of the available parity distribution methods.
|
|
|
|
A RAID-6 set of N drives with a capacity of C MB per drive
|
|
provides the capacity of C * (N - 2) MB, and protects
|
|
against a failure of any two drives. For a given sector
|
|
(row) number, (N - 2) drives contain data sectors, and two
|
|
drives contains two independent redundancy syndromes. Like
|
|
RAID-5, RAID-6 distributes the syndromes across the drives
|
|
in one of the available parity distribution methods.
|
|
|
|
config DM_ZERO
|
|
tristate "Zero target"
|
|
depends on BLK_DEV_DM
|
|
---help---
|
|
A target that discards writes, and returns all zeroes for
|
|
reads. Useful in some recovery situations.
|
|
|
|
config DM_MULTIPATH
|
|
tristate "Multipath target"
|
|
depends on BLK_DEV_DM
|
|
# nasty syntax but means make DM_MULTIPATH independent
|
|
# of SCSI_DH if the latter isn't defined but if
|
|
# it is, DM_MULTIPATH must depend on it. We get a build
|
|
# error if SCSI_DH=m and DM_MULTIPATH=y
|
|
depends on SCSI_DH || !SCSI_DH
|
|
---help---
|
|
Allow volume managers to support multipath hardware.
|
|
|
|
config DM_MULTIPATH_QL
|
|
tristate "I/O Path Selector based on the number of in-flight I/Os"
|
|
depends on DM_MULTIPATH
|
|
---help---
|
|
This path selector is a dynamic load balancer which selects
|
|
the path with the least number of in-flight I/Os.
|
|
|
|
If unsure, say N.
|
|
|
|
config DM_MULTIPATH_ST
|
|
tristate "I/O Path Selector based on the service time"
|
|
depends on DM_MULTIPATH
|
|
---help---
|
|
This path selector is a dynamic load balancer which selects
|
|
the path expected to complete the incoming I/O in the shortest
|
|
time.
|
|
|
|
If unsure, say N.
|
|
|
|
config DM_DELAY
|
|
tristate "I/O delaying target"
|
|
depends on BLK_DEV_DM
|
|
---help---
|
|
A target that delays reads and/or writes and can send
|
|
them to different devices. Useful for testing.
|
|
|
|
If unsure, say N.
|
|
|
|
config DM_UEVENT
|
|
bool "DM uevents"
|
|
depends on BLK_DEV_DM
|
|
---help---
|
|
Generate udev events for DM events.
|
|
|
|
config DM_FLAKEY
|
|
tristate "Flakey target"
|
|
depends on BLK_DEV_DM
|
|
---help---
|
|
A target that intermittently fails I/O for debugging purposes.
|
|
|
|
config DM_VERITY
|
|
tristate "Verity target support"
|
|
depends on BLK_DEV_DM
|
|
select CRYPTO
|
|
select CRYPTO_HASH
|
|
select DM_BUFIO
|
|
---help---
|
|
This device-mapper target creates a read-only device that
|
|
transparently validates the data on one underlying device against
|
|
a pre-generated tree of cryptographic checksums stored on a second
|
|
device.
|
|
|
|
You'll need to activate the digests you're going to use in the
|
|
cryptoapi configuration.
|
|
|
|
To compile this code as a module, choose M here: the module will
|
|
be called dm-verity.
|
|
|
|
If unsure, say N.
|
|
|
|
config DM_SWITCH
|
|
tristate "Switch target support (EXPERIMENTAL)"
|
|
depends on BLK_DEV_DM
|
|
---help---
|
|
This device-mapper target creates a device that supports an arbitrary
|
|
mapping of fixed-size regions of I/O across a fixed set of paths.
|
|
The path used for any specific region can be switched dynamically
|
|
by sending the target a message.
|
|
|
|
To compile this code as a module, choose M here: the module will
|
|
be called dm-switch.
|
|
|
|
If unsure, say N.
|
|
|
|
endif # MD
|