linux/Documentation/devicetree/bindings/display/panel/boe,hv070wsa-100.txt
Andrzej Hajda b0b7aa407e dt-bindings: display: Add DT bindings for BOE HV070WSA-100 panel
The patch adds bindings to BOE HV070-WSA WSVGA panel. Bindings are
compatible with simple panel bindings.

Signed-off-by: Andrzej Hajda <a.hajda@samsung.com>
Signed-off-by: Maciej Purski <m.purski@samsung.com>
Reviewed-by: Rob Herring <robh@kernel.org>
Signed-off-by: Thierry Reding <treding@nvidia.com>
Link: https://patchwork.freedesktop.org/patch/msgid/1529396370-18761-5-git-send-email-m.purski@samsung.com
2018-07-10 17:59:05 +02:00

29 lines
829 B
Plaintext

BOE HV070WSA-100 7.01" WSVGA TFT LCD panel
Required properties:
- compatible: should be "boe,hv070wsa-100"
- power-supply: regulator to provide the VCC supply voltage (3.3 volts)
- enable-gpios: GPIO pin to enable and disable panel (active high)
This binding is compatible with the simple-panel binding, which is specified
in simple-panel.txt in this directory.
The device node can contain one 'port' child node with one child
'endpoint' node, according to the bindings defined in [1]. This
node should describe panel's video bus.
[1]: Documentation/devicetree/bindings/media/video-interfaces.txt
Example:
panel: panel {
compatible = "boe,hv070wsa-100";
power-supply = <&vcc_3v3_reg>;
enable-gpios = <&gpd1 3 GPIO_ACTIVE_HIGH>;
port {
panel_ep: endpoint {
remote-endpoint = <&bridge_out_ep>;
};
};
};