mirror of
https://github.com/torvalds/linux.git
synced 2024-11-29 23:51:37 +00:00
d89af13c92
This commit refactors the existing cgroup program with libbpf bpf
loader. The original test_cgrp2_sock2 has keeped the bpf program
attached to the cgroup hierarchy even after the exit of user program.
To implement the same functionality with libbpf, this commit uses the
BPF_LINK_PINNING to pin the link attachment even after it is closed.
Since this uses LINK instead of ATTACH, detach of bpf program from
cgroup with 'test_cgrp2_sock' is not used anymore.
The code to mount the bpf was added to the .sh file in case the bpff
was not mounted on /sys/fs/bpf. Additionally, to fix the problem that
shell script cannot find the binary object from the current path,
relative path './' has been added in front of binary.
Fixes: 554ae6e792
("samples/bpf: add userspace example for prohibiting sockets")
Signed-off-by: Daniel T. Lee <danieltimlee@gmail.com>
Signed-off-by: Andrii Nakryiko <andrii@kernel.org>
Link: https://lore.kernel.org/bpf/20201124090310.24374-3-danieltimlee@gmail.com
99 lines
1.8 KiB
Bash
Executable File
99 lines
1.8 KiB
Bash
Executable File
#!/bin/bash
|
|
# SPDX-License-Identifier: GPL-2.0
|
|
|
|
BPFFS=/sys/fs/bpf
|
|
LINK_PIN=$BPFFS/test_cgrp2_sock2
|
|
|
|
function config_device {
|
|
ip netns add at_ns0
|
|
ip link add veth0 type veth peer name veth0b
|
|
ip link set veth0b up
|
|
ip link set veth0 netns at_ns0
|
|
ip netns exec at_ns0 ip addr add 172.16.1.100/24 dev veth0
|
|
ip netns exec at_ns0 ip addr add 2401:db00::1/64 dev veth0 nodad
|
|
ip netns exec at_ns0 ip link set dev veth0 up
|
|
ip addr add 172.16.1.101/24 dev veth0b
|
|
ip addr add 2401:db00::2/64 dev veth0b nodad
|
|
}
|
|
|
|
function config_cgroup {
|
|
rm -rf /tmp/cgroupv2
|
|
mkdir -p /tmp/cgroupv2
|
|
mount -t cgroup2 none /tmp/cgroupv2
|
|
mkdir -p /tmp/cgroupv2/foo
|
|
echo $$ >> /tmp/cgroupv2/foo/cgroup.procs
|
|
}
|
|
|
|
function config_bpffs {
|
|
if mount | grep $BPFFS > /dev/null; then
|
|
echo "bpffs already mounted"
|
|
else
|
|
echo "bpffs not mounted. Mounting..."
|
|
mount -t bpf none $BPFFS
|
|
fi
|
|
}
|
|
|
|
function attach_bpf {
|
|
./test_cgrp2_sock2 /tmp/cgroupv2/foo sock_flags_kern.o $1
|
|
[ $? -ne 0 ] && exit 1
|
|
}
|
|
|
|
function cleanup {
|
|
rm -rf $LINK_PIN
|
|
ip link del veth0b
|
|
ip netns delete at_ns0
|
|
umount /tmp/cgroupv2
|
|
rm -rf /tmp/cgroupv2
|
|
}
|
|
|
|
cleanup 2>/dev/null
|
|
|
|
set -e
|
|
config_device
|
|
config_cgroup
|
|
config_bpffs
|
|
set +e
|
|
|
|
#
|
|
# Test 1 - fail ping6
|
|
#
|
|
attach_bpf 0
|
|
ping -c1 -w1 172.16.1.100
|
|
if [ $? -ne 0 ]; then
|
|
echo "ping failed when it should succeed"
|
|
cleanup
|
|
exit 1
|
|
fi
|
|
|
|
ping6 -c1 -w1 2401:db00::1
|
|
if [ $? -eq 0 ]; then
|
|
echo "ping6 succeeded when it should not"
|
|
cleanup
|
|
exit 1
|
|
fi
|
|
|
|
rm -rf $LINK_PIN
|
|
sleep 1 # Wait for link detach
|
|
|
|
#
|
|
# Test 2 - fail ping
|
|
#
|
|
attach_bpf 1
|
|
ping6 -c1 -w1 2401:db00::1
|
|
if [ $? -ne 0 ]; then
|
|
echo "ping6 failed when it should succeed"
|
|
cleanup
|
|
exit 1
|
|
fi
|
|
|
|
ping -c1 -w1 172.16.1.100
|
|
if [ $? -eq 0 ]; then
|
|
echo "ping succeeded when it should not"
|
|
cleanup
|
|
exit 1
|
|
fi
|
|
|
|
cleanup
|
|
echo
|
|
echo "*** PASS ***"
|