Commit Graph

3575 Commits

Author SHA1 Message Date
Johan Hedberg
88d9077c27 Bluetooth: Fix potential NULL dereference
The bnep_get_device function may be triggered by an ioctl just after a
connection has gone down. In such a case the respective L2CAP chan->conn
pointer will get set to NULL (by l2cap_chan_del). This patch adds a
missing NULL check for this case in the bnep_get_device() function.

Reported-by: Patrik Flykt <patrik.flykt@linux.intel.com>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
2015-02-03 09:02:12 +01:00
Johan Hedberg
66f096f791 Bluetooth: Remove mgmt_rp_read_local_oob_ext_data struct
This extended return parameters struct conflicts with the new Read Local
OOB Extended Data command definition. To avoid the conflict simply
rename the old "extended" version to the normal one and update the code
appropriately to take into account the two possible response PDU sizes.

Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
2015-02-02 18:27:56 +01:00
Jakub Pawlowski
4b0e0ceddf Bluetooth: Add restarting to service discovery
When using LE_SCAN_FILTER_DUP_ENABLE, some controllers would send
advertising report from each LE device only once. That means that we
don't get any updates on RSSI value, and makes Service Discovery very
slow. This patch adds restarting scan when in Service Discovery, and
device with filtered uuid is found, but it's not in RSSI range to send
event yet. This way if device moves into range, we will quickly get RSSI
update.

Signed-off-by: Jakub Pawlowski <jpawlowski@google.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
2015-02-02 08:52:34 +01:00
Jakub Pawlowski
2d28cfe7aa Bluetooth: Add le_scan_restart work for LE scan restarting
Currently there is no way to restart le scan, and it's needed in
service scan method. The way it work: it disable, and then enable le
scan on controller.

During the restart, we must remember when the scan was started, and
it's duration, to later re-schedule the le_scan_disable work, that was
stopped during the stop scan phase.

Signed-off-by: Jakub Pawlowski <jpawlowski@google.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
2015-02-02 08:52:33 +01:00
Marcel Holtmann
bf21d7931a Bluetooth: Fix OOB data present for BR/EDR Secure Connections Only mode
When using Secure Connections Only mode, then only P-256 OOB data is
valid and should be provided. In case userspace provides P-192 and P-256
OOB data, then the P-192 values will be set to zero. However the present
value of the IO capability exchange still mentioned that both values
would be available. Fix this by telling the controller clearly that only
the P-256 OOB data is present.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-02-01 11:52:54 +02:00
Marcel Holtmann
6858bcd073 Bluetooth: Expose remote OOB information as debugfs entry
For debugging purposes it is good to know which OOB data is actually
currently loaded for each controller. So expose that list via debugfs.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-02-01 09:15:21 +02:00
Marcel Holtmann
5789f37cbc Bluetooth: Expose hardware error code as debugfs entry
When the Hardware Error event is send by the controller, the Bluetooth
core stores the error code. Expose it via debugfs so it can be retrieved
later on.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-02-01 09:14:55 +02:00
Marcel Holtmann
0886aea6ac Bluetooth: Expose debug keys usage setting via debugfs
To allow easier debugging when debug keys are generated, provide debugfs
entry for checking the setting of debug keys usage.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-02-01 09:14:19 +02:00
Marcel Holtmann
c50b33c80e Bluetooth: Track changes from HCI Write Simple Pairing Debug Mode command
When the HCI Write Simple Pairing Debug Mode command has been issued,
the result needs to be tracked and stored. The hdev->ssp_debug_mode
variable is already present, but was never updated when the mode in
the controller was actually changed.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-02-01 09:13:23 +02:00
Marcel Holtmann
6e07231a80 Bluetooth: Expose Secure Simple Pairing debug mode setting in debugfs
The value of the ssp_debug_mode should be accessible via debugfs to be
able to determine if a BR/EDR controller generates debugs keys or not.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-02-01 09:12:56 +02:00
Marcel Holtmann
41bcfd50d5 Bluetooth: Allow remote OOB data to only provide P-192 or P-256 values
In case the remote only provided P-192 or P-256 data for OOB pairing,
then make sure that the data value pointers are correctly set. That way
the core can provide correct information when remote OOB data present
information have to be communicated.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-31 21:26:14 +01:00
Marcel Holtmann
4775a4ea14 Bluetooth: Fix OOB data present value for SMP pairing
Before setting the OOB data present flag with SMP pairing, check the
newly introduced present tracking that actual OOB data values have
been provided. The existence of remote OOB data structure does not
actually mean that the correct data values are available.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-31 21:26:14 +01:00
Marcel Holtmann
659c7fb084 Bluetooth: Fix OOB data present value for BR/EDR Secure Connections
When BR/EDR Secure Connections has been enabled, the OOB data present
value can take 2 additional values. The host has to clearly provide
details about if P-192 OOB data, P-256 OOB data or a combination of
P-192 and P-256 OOB data is present.

In case BR/EDR Secure Connections is not enabled or not supported,
then check that P-192 OOB data is actually present and return the
correct value based on that.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-31 21:26:12 +01:00
Marcel Holtmann
f7697b1602 Bluetooth: Store OOB data present value for each set of remote OOB data
Instead of doing complex calculation every time the OOB data is used,
just calculate the OOB data present value and store it with the OOB
data raw values.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-31 09:59:45 +02:00
Szymon Janc
ac363cf9eb Bluetooth: Fix sending Read Remote Extended Features command
This command should only be used if remote device reports that it
supports extended features. Otherwise command will fail and connection
will be dropped.

Some devices support SSP but don't support extended features so
current check for SSP support is not enought.

Instead of checking for SSP support just check if both ends support
Extended Feature.

< HCI Command: Create Connection (0x01|0x0005) plen 13
        Address: D0:9C:30:00:19:6F (Foster Electric Company, Limited)
        Packet type: 0xcc18
          DM1 may be used
          DH1 may be used
          DM3 may be used
          DH3 may be used
          DM5 may be used
          DH5 may be used
        Page scan repetition mode: R1 (0x01)
        Page scan mode: Mandatory (0x00)
        Clock offset: 0x94c8
        Role switch: Allow slave (0x01)
> HCI Event: Command Status (0x0f) plen 4
      Create Connection (0x01|0x0005) ncmd 1
        Status: Success (0x00)
> HCI Event: Connect Complete (0x03) plen 11
        Status: Success (0x00)
        Handle: 5
        Address: D0:9C:30:00:19:6F (Foster Electric Company, Limited)
        Link type: ACL (0x01)
        Encryption: Disabled (0x00)
< HCI Command: Read Remote Supported Features (0x01|0x001b) plen 2
        Handle: 5
> HCI Event: Command Status (0x0f) plen 4
      Read Remote Supported Features (0x01|0x001b) ncmd 1
        Status: Success (0x00)
> HCI Event: Page Scan Repetition Mode Change (0x20) plen 7
        Address: D0:9C:30:00:19:6F (Foster Electric Company, Limited)
        Page scan repetition mode: R1 (0x01)
> HCI Event: Read Remote Supported Features (0x0b) plen 11
        Status: Success (0x00)
        Handle: 5
        Features: 0xff 0xff 0x8f 0xfe 0xdb 0xff 0x5b 0x07
          3 slot packets
          5 slot packets
          Encryption
          Slot offset
          Timing accuracy
          Role switch
          Hold mode
          Sniff mode
          Park state
          Power control requests
          Channel quality driven data rate (CQDDR)
          SCO link
          HV2 packets
          HV3 packets
          u-law log synchronous data
          A-law log synchronous data
          CVSD synchronous data
          Paging parameter negotiation
          Power control
          Transparent synchronous data
          Broadcast Encryption
          Enhanced Data Rate ACL 2 Mbps mode
          Enhanced Data Rate ACL 3 Mbps mode
          Enhanced inquiry scan
          Interlaced inquiry scan
          Interlaced page scan
          RSSI with inquiry results
          Extended SCO link (EV3 packets)
          EV4 packets
          EV5 packets
          AFH capable slave
          AFH classification slave
          LE Supported (Controller)
          3-slot Enhanced Data Rate ACL packets
          5-slot Enhanced Data Rate ACL packets
          Sniff subrating
          Pause encryption
          AFH capable master
          AFH classification master
          Enhanced Data Rate eSCO 2 Mbps mode
          Enhanced Data Rate eSCO 3 Mbps mode
          3-slot Enhanced Data Rate eSCO packets
          Extended Inquiry Response
          Simultaneous LE and BR/EDR (Controller)
          Secure Simple Pairing
          Encapsulated PDU
          Non-flushable Packet Boundary Flag
          Link Supervision Timeout Changed Event
          Inquiry TX Power Level
          Enhanced Power Control
< HCI Command: Read Remote Extended Features (0x01|0x001c) plen 3
        Handle: 5
        Page: 1
> HCI Event: Command Status (0x0f) plen 4
      Read Remote Extended Features (0x01|0x001c) ncmd 1
        Status: Command Disallowed (0x0c)
< HCI Command: Read Clock Offset (0x01|0x001f) plen 2
        Handle: 5
> HCI Event: Command Status (0x0f) plen 4
      Read Clock Offset (0x01|0x001f) ncmd 1
        Status: Success (0x00)
< HCI Command: Disconnect (0x01|0x0006) plen 3
        Handle: 5
        Reason: Remote User Terminated Connection (0x13)

Signed-off-by: Szymon Janc <szymon.janc@tieto.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
2015-01-29 16:59:53 +01:00
Marcel Holtmann
64dae967ca Bluetooth: Move smp_unregister() into hci_dev_do_close() function
The smp_unregister() function needs to be called every time the
controller is powered down. There are multiple entry points when
this can happen. One is "hciconfig hci0 reset" which will throw
a WARN_ON when LE support has been enabled.

[   78.564620] WARNING: CPU: 0 PID: 148 at net/bluetooth/smp.c:3075 smp_register+0xf1/0x170()
[   78.564622] Modules linked in:
[   78.564628] CPU: 0 PID: 148 Comm: kworker/u3:1 Not tainted 3.19.0-rc4-devel+ #404
[   78.564629] Hardware name: QEMU Standard PC (i440FX + PIIX, 1996), BIOS
[   78.564635] Workqueue: hci0 hci_rx_work
[   78.564638]  ffffffff81b4a7a2 ffff88001cb2fb38 ffffffff8161d881 0000000080000000
[   78.564642]  0000000000000000 ffff88001cb2fb78 ffffffff8103b870 696e55206e6f6f6d
[   78.564645]  ffff88001d965000 0000000000000000 0000000000000000 ffff88001d965000
[   78.564648] Call Trace:
[   78.564655]  [<ffffffff8161d881>] dump_stack+0x4f/0x7b
[   78.564662]  [<ffffffff8103b870>] warn_slowpath_common+0x80/0xc0
[   78.564667]  [<ffffffff81544b00>] ? add_uuid+0x1f0/0x1f0
[   78.564671]  [<ffffffff8103b955>] warn_slowpath_null+0x15/0x20
[   78.564674]  [<ffffffff81562d81>] smp_register+0xf1/0x170
[   78.564680]  [<ffffffff81081236>] ? lock_timer_base.isra.30+0x26/0x50
[   78.564683]  [<ffffffff81544bf0>] powered_complete+0xf0/0x120
[   78.564688]  [<ffffffff8152e622>] hci_req_cmd_complete+0x82/0x260
[   78.564692]  [<ffffffff8153554f>] hci_cmd_complete_evt+0x6cf/0x2e20
[   78.564697]  [<ffffffff81623e43>] ? _raw_spin_unlock_irqrestore+0x13/0x30
[   78.564701]  [<ffffffff8106b0af>] ? __wake_up_sync_key+0x4f/0x60
[   78.564705]  [<ffffffff8153a2ab>] hci_event_packet+0xbcb/0x2e70
[   78.564709]  [<ffffffff814094d3>] ? skb_release_all+0x23/0x30
[   78.564711]  [<ffffffff81409529>] ? kfree_skb+0x29/0x40
[   78.564715]  [<ffffffff815296c8>] hci_rx_work+0x1c8/0x3f0
[   78.564719]  [<ffffffff8105bd91>] ? get_parent_ip+0x11/0x50
[   78.564722]  [<ffffffff8105be25>] ? preempt_count_add+0x55/0xb0
[   78.564727]  [<ffffffff8104f65f>] process_one_work+0x12f/0x360
[   78.564731]  [<ffffffff8104ff9b>] worker_thread+0x6b/0x4b0
[   78.564735]  [<ffffffff8104ff30>] ? cancel_delayed_work_sync+0x10/0x10
[   78.564738]  [<ffffffff810542fa>] kthread+0xea/0x100
[   78.564742]  [<ffffffff81620000>] ? __schedule+0x3e0/0x980
[   78.564745]  [<ffffffff81054210>] ? kthread_create_on_node+0x180/0x180
[   78.564749]  [<ffffffff816246ec>] ret_from_fork+0x7c/0xb0
[   78.564752]  [<ffffffff81054210>] ? kthread_create_on_node+0x180/0x180
[   78.564755] ---[ end trace 8b0d943af76d3736 ]---

This warning is not critical and has only been placed in the code to
actually catch this exact situation. To avoid triggering it move
the smp_unregister() into hci_dev_do_close() which will now also
take care of remove the SMP channel. It is safe to call this function
since it only remove the channel if it has been previously registered.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-29 07:53:42 +02:00
Marcel Holtmann
c7741d16a5 Bluetooth: Perform a power cycle when receiving hardware error event
When receiving a HCI Hardware Error event, the controller should be
assumed to be non-functional until issuing a HCI Reset command.

The Bluetooth hardware errors are vendor specific and so add a
new hdev->hw_error callback that drivers can provide to run extra
code to handle the hardware error.

After completing the vendor specific error handling perform a full
reset of the Bluetooth stack by closing and re-opening the transport.

Based-on-patch-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-28 21:26:24 +01:00
Marcel Holtmann
5c912495b7 Bluetooth: Introduce hci_dev_do_reset helper function
Split the hci_dev_reset ioctl handling into using hci_dev_do_reset
helper function. Similar to what has been done with hci_dev_do_open
and hci_dev_do_close.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-28 21:26:24 +01:00
Johan Hedberg
8f502f847a Bluetooth: Fix notifying discovery state when powering off
The discovery state should be set to stopped when the HCI device is
powered off. This patch adds the appropriate call to the
hci_discovery_set_state() function from hci_dev_do_close() which is
responsible for the power-off procedure.

Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
2015-01-28 21:26:23 +01:00
Johan Hedberg
39c5d970d4 Bluetooth: Fix notifying discovery state upon reset
When HCI_Reset is issued the discovery state is assumed to be stopped.
The hci_cc_reset() handler was trying to set the state but it was doing
it without using the hci_discovery_set_state() function. Because of this
e.g. the mgmt Discovering event could go without being sent. This patch
fixes the code to use the hci_discovery_set_state() function instead of
just blindly setting the state value.

Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
2015-01-28 21:26:23 +01:00
Johan Hedberg
592002863a Bluetooth: Fix check for SSP when enabling SC
There's a check in set_secure_conn() that's supposed to ensure that SSP
is enabled before we try to request the controller to enable SC (since
SSP is a pre-requisite for it). However, this check only makes sense for
controllers actually supporting BR/EDR SC. If we have a 4.0 controller
we're only interested in the LE part of SC and should therefore not be
requiring SSP to be enabled. This patch adds an additional condition to
check for lmp_sc_capable(hdev) before requiring SSP to be enabled.

Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
2015-01-28 21:26:22 +01:00
Marcel Holtmann
aa5b034565 Bluetooth: Check for P-256 OOB values in Secure Connections Only mode
If Secure Connections Only mode has been enabled, the it is important
to check that OOB data for P-256 values is provided. In case it is not,
then tell the remote side that no OOB data is present.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-28 21:26:21 +01:00
Marcel Holtmann
a83ed81ef5 Bluetooth: Use helper function to determine BR/EDR OOB data present
When replying to the IO capability request for Secure Simple Pairing and
Secure Connections, the OOB data present fields needs to set. Instead of
making the calculation inline, split this into a separate helper
function.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-28 21:26:20 +01:00
Marcel Holtmann
6665d057fb Bluetooth: Clear P-192 values for OOB when in Secure Connections Only mode
When Secure Connections Only mode has been enabled and remote OOB data
is requested, then only provide P-256 hash and randomizer vaulues. The
fields for P-192 hash and randomizer should be set to zero.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-28 21:26:20 +01:00
Johan Hedberg
d25b78e2ed Bluetooth: Enforce zero-valued hash/rand192 for LE OOB
Until legacy SMP OOB pairing is implemented user space should be given a
clear error when trying to use it. This patch adds a corresponding check
to the Add Remote OOB Data handler function which returns "invalid
parameters" if non-zero Rand192 or Hash192 parameters were given for an
LE address.

Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
2015-01-28 21:26:19 +01:00
Peter Hurley
dfb2fae7cd Bluetooth: Fix nested sleeps
l2cap/rfcomm/sco_sock_accept() are wait loops which may acquire
sleeping locks. Since both wait loops and sleeping locks use
task_struct.state to sleep and wake, the nested sleeping locks
destroy the wait loop state.

Use the newly-minted wait_woken() and DEFINE_WAIT_FUNC() for the
wait loop. DEFINE_WAIT_FUNC() allows an alternate wake function
to be specified; in this case, the predefined scheduler function,
woken_wake_function(). This wait construct ensures wakeups will
not be missed without requiring the wait loop to set the
task state before condition evaluation. How this works:

 CPU 0                            |  CPU 1
                                  |
                                  | is <condition> set?
                                  | no
set <condition>                   |
                                  |
wake_up_interruptible             |
  woken_wake_function             |
    set WQ_FLAG_WOKEN             |
    try_to_wake_up                |
                                  | wait_woken
                                  |   set TASK_INTERRUPTIBLE
                                  |   WQ_FLAG_WOKEN? yes
                                  |   set TASK_RUNNING
                                  |
                                  | - loop -
				  |
				  | is <condition> set?
                                  | yes - exit wait loop

Fixes "do not call blocking ops when !TASK_RUNNING" warnings
in l2cap_sock_accept(), rfcomm_sock_accept() and sco_sock_accept().

Signed-off-by: Peter Hurley <peter@hurleysoftware.com>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-23 20:29:42 +02:00
Johan Hedberg
a1443f5a27 Bluetooth: Convert Set SC to use HCI Request
This patch converts the Set Secure Connection HCI handling to use a HCI
request instead of using a hard-coded callback in hci_event.c. This e.g.
ensures that we don't clear the flags incorrectly if something goes
wrong with the power up process (not related to a mgmt Set SC command).

The code can also be simplified a bit since only one pending Set SC
command is allowed, i.e. mgmt_pending_foreach usage is not needed.

Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
2015-01-23 19:07:03 +01:00
Johan Hedberg
484aabc1c4 Bluetooth: Remove incorrect check for BDADDR_BREDR address type
The Add Remote OOB Data mgmt command should allow data to be passed for
LE as well. This patch removes a left-over check for BDADDR_BREDR that
should not be there anymore.

Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
2015-01-23 18:59:31 +01:00
Johan Hedberg
5d57e7964c Bluetooth: Check for valid bdaddr in add_remote_oob_data
Before doing any other verifications, the add_remote_oob_data function
should first check that the given address is valid. This patch adds such
a missing check to the beginning of the function.

Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
2015-01-23 18:59:30 +01:00
Marcel Holtmann
ed93ec69c7 Bluetooth: Require SSP enabling before BR/EDR Secure Connections
When BR/EDR is supported by a controller, then it is required to enable
Secure Simple Pairing first before enabling the Secure Connections
feature.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-22 21:44:20 +02:00
Marcel Holtmann
3a5486e1fd Bluetooth: Limit BR/EDR switching for LE only with secure connections
When a powered on dual-mode controller has been configured to operate
as LE only with secure connections, then the BR/EDR side of things can
not be switched back on. Do reconfigure the controller it first needs
to be powered down.

The secure connections feature is implemented in the BR/EDR controller
while for LE it is implemented in the host. So explicitly forbid such
a transaction to avoid inconsistent states.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-22 21:42:45 +02:00
Marcel Holtmann
574ea3c713 Bluetooth: Fix dependency for BR/EDR Secure Connections mode on SSP
The BR/EDR Secure Connections feature should only be enabled when the
Secure Simple Pairing mode has been enabled first. However since secure
connections is feature that is valid for BR/EDR and LE, this needs
special handling.

When enabling secure connections on a LE only configured controller,
thent the BR/EDR side should not be enabled in the controller. This
patches makes the BR/EDR Secure Connections feature depending on
enabling Secure Simple Pairing mode first.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-22 21:42:18 +02:00
Szymon Janc
91200e9f3e Bluetooth: Fix reporting invalid RSSI for LE devices
Start Discovery was reporting 0 RSSI for invalid RSSI only for
BR/EDR devices. LE devices were reported with RSSI 127.

Signed-off-by: Szymon Janc <szymon.janc@tieto.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Cc: stable@vger.kernel.org # 3.19+
2015-01-22 18:06:43 +01:00
Rickard Strandqvist
0026b6551b Bluetooth: Remove unused function
Remove the function hci_conn_change_link_key() that is not used anywhere.

This was partially found by using a static code analysis program called
cppcheck.

Signed-off-by: Rickard Strandqvist <rickard_strandqvist@spectrumdigital.se>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-16 13:06:38 +02:00
Marcel Holtmann
2b8df32395 Bluetooth: Add paranoid check for existing LE and BR/EDR SMP channels
When the SMP channels have been already registered, then print out a
clear WARN_ON message that something went wrong. Also unregister the
existing channels in this case before trying to register new ones.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-15 21:59:38 +02:00
Johan Hedberg
327a71910c Bluetooth: Fix lookup of fixed channels by local bdaddr
The comparing of chan->src should always be done against the local
identity address, represented by hcon->src and hcon->src_type. This
patch modifies l2cap_global_fixed_chan() to take the full hci_conn so
that we can easily compare against hcon->src and hcon->src_type.

Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
2015-01-15 16:54:14 +01:00
Johan Hedberg
a250e048a7 Bluetooth: Add helpers for src/dst bdaddr type conversion
The current bdaddr_type() usage in l2cap_core.c is a bit funny in that
it's always passed a hci_conn + a hci_conn member. Because of this only
the hci_conn is really needed. Since the second parameter is always
either hcon->src_type or hcon->dst type this patch adds two helper
functions for each purpose: bdaddr_src_type() and bdaddr_dst_type().

Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
2015-01-15 16:54:14 +01:00
Marcel Holtmann
162a3bac8d Bluetooth: Bind the SMP channel registration to management power state
When the controller gets powered on via the management interface, then
register the supported SMP channels. There is no point in registering
these channels earlier since it is not know what identity address the
controller is going to operate with.

When powering down a controller unregister all SMP channels. This is
required since a powered down controller is allowed to change its
identity address.

In addition the SMP channels are only available when the controller
is powered via the management interface. When using legacy ioctl, then
Bluetooth Low Energy is not supported and registering kernel side SMP
integration may actually cause confusion.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-15 12:54:31 +02:00
Marcel Holtmann
7e7ec44564 Bluetooth: Don't register any SMP channel if LE is not supported
When LE features are not supported, then do not bother registering any
kind of SMP channel.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-15 12:54:30 +02:00
Marcel Holtmann
157029ba30 Bluetooth: Fix LE SMP channel source address and source address type
The source address and source address type of the LE SMP channel can
either be the public address of the controller or the static random
address configured by the host.

Right now the public address is used for the LE SMP channel and
obviously that is not correct if the controller operates with the
configured static random address.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-15 12:54:30 +02:00
Marcel Holtmann
111e4bccd1 Bluetooth: Fix issue with switching BR/EDR back on when disabled
For dual-mode controllers it is possible to disable BR/EDR and operate
as LE single mode controllers with a static random address. If that is
the case, then refuse switching BR/EDR back on after the controller has
been powered.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-15 10:27:47 +02:00
Marcel Holtmann
eeb5a067d1 Bluetooth: Show device address type for L2CAP debugfs entries
The devices address types are BR/EDR Public, LE Public and LE Random and
any of these three is valid for L2CAP connections. So show the correct
type in the debugfs list.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-15 10:23:47 +02:00
Jukka Rissanen
7b2ed60ed4 Bluetooth: 6lowpan: Remove PSM setting code
Removing PSM setting debugfs interface as the IPSP has a well
defined PSM value that should be used.

The patch introduces enable flag that can be used to toggle
6lowpan on/off.

Signed-off-by: Jukka Rissanen <jukka.rissanen@linux.intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
2015-01-14 22:48:13 +01:00
Johan Hedberg
e12af489b9 Bluetooth: Fix valid Identity Address check
According to the Bluetooth core specification valid identity addresses
are either Public Device Addresses or Static Random Addresses. IRKs
received with any other type of address should be discarded since we
cannot assume to know the permanent identity of the peer device.

This patch fixes a missing check for the Identity Address when receiving
the Identity Address Information SMP PDU.

Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Cc: stable@vger.kernel.org # 3.17+
2015-01-14 22:48:06 +01:00
Gowtham Anandha Babu
36c269cecf Bluetooth: Remove dead code
Variable 'controller' is assigned a value that is never used.
Identified by cppcheck tool.

Signed-off-by: Gowtham Anandha Babu <gowtham.ab@samsung.com>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-14 11:16:17 +02:00
Marcel Holtmann
5ced24644b Bluetooth: Use %llu for printing duration details of selftests
The duration variable for the selftests is unsigned long long and with
that use %llu instead of %lld when printing the results.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-14 10:02:45 +02:00
Marcel Holtmann
36f260ceff Bluetooth: Move Delete Stored Link Key to 4th phase of initialization
This moves the execution of Delete Stored Link Key command to the
hci_init4_req phase. No actual code has been changed. The command
is just executed at a later stage of the initialization.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-14 10:02:21 +02:00
Marcel Holtmann
a936612036 Bluetooth: Process result of HCI Delete Stored Link Key command
When the HCI Delete Stored Link Key command completes, then update the
value of current stored keys in hci_dev structure.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-12 21:56:06 +02:00
Marcel Holtmann
48ce62c4fa Bluetooth: Read stored link key information when powering on controller
The information about max stored link keys and current stored link keys
should be read at controller initialization. So issue HCI Read Stored
Link Key command with BDADDR_ANY and read_all flag set to 0x01 to
retrieve this information.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-12 21:54:48 +02:00
Marcel Holtmann
c2f0f97927 Bluetooth: Handle command complete event for HCI Read Stored Link Keys
When the HCI Read Stored Link Keys command completes it gives useful
information of the current stored keys and maximum keys a controller
can actually store. So process this event and store these information
in hci_dev structure.

Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
2015-01-12 21:54:16 +02:00