Each authentication step is required to be completed within the
KATO interval (or two minutes if not set). So add a workqueue function
to reset the transaction ID and the expected next protocol step;
this will automatically the next authentication command referring
to the terminated authentication.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
Implement Diffie-Hellman key exchange using FFDHE groups for NVMe
In-Band Authentication.
This patch adds a new host configfs attribute 'dhchap_dhgroup' to
select the FFDHE group to use.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
Implement NVMe-oF In-Band authentication according to NVMe TPAR 8006.
This patch adds three additional configfs entries 'dhchap_key',
'dhchap_ctrl_key', and 'dhchap_hash' to the 'host' configfs directory.
The 'dhchap_key' and 'dhchap_ctrl_key' entries need to be in the ASCII
format as specified in NVMe Base Specification v2.0 section 8.13.5.8
'Secret representation'.
'dhchap_hash' defaults to 'hmac(sha256)', and can be written to to
switch to a different HMAC algorithm.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
Some fabrics commands can be sent via io queues, so add a new
function nvmet_parse_fabrics_io_cmd() and rename the existing
nvmet_parse_fabrics_cmd() to nvmet_parse_fabrics_admin_cmd().
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
If the clear_ids attribute is set to true, the EUI/GUID/UUID is cleared
for the passthru target. By default, loop targets will set clear_ids to
true.
This resolves an issue where a connect to a passthru target fails when
using a trtype of 'loop' because EUI/GUID/UUID is not unique.
Fixes: 2079f41ec6 ("nvme: check that EUI/GUID/UUID are globally unique")
Signed-off-by: Alan Adamson <alan.adamson@oracle.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Chaitanya Kulkarni <kch@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Any attempt to flush kernel-global WQs has possibility of deadlock
so we should simply stop using them, instead introduce nvmet_wq
which is the generic nvmet workqueue for work elements that
don't explicitly require a dedicated workqueue (by the mere fact
that they are using the system_wq).
Changes were done using the following replaces:
- s/schedule_work(/queue_work(nvmet_wq, /g
- s/schedule_delayed_work(/queue_delayed_work(nvmet_wq, /g
- s/flush_scheduled_work()/flush_workqueue(nvmet_wq)/g
Reported-by: Tetsuo Handa <penguin-kernel@I-love.SAKURA.ne.jp>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <kch@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
nvmet_ns_changed states via lockdep that the ns->subsys->lock must be
held. The only caller of nvmet_ns_changed which does not acquire that
lock is nvmet_ns_revalidate. nvmet_ns_revalidate has 3 callers,
of which 2 do not acquire that lock: nvmet_execute_identify_cns_cs_ns
and nvmet_execute_identify_ns. The other caller
nvmet_ns_revalidate_size_store does acquire the lock.
Move the call to nvmet_ns_changed from nvmet_ns_revalidate to the callers
so that they can perform the correct locking as needed.
This issue was found using a static type-based analyser and manually
verified.
Reported-by: Niels Dossche <dossche.niels@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <kch@nvidia.com>
Instead of calling vfs_getattr() use i_size_read() to read the size of
file so we can read the size of not only file type but also block type
with one call. This is needed to implement buffered_io support for the
NVMeOF block device backend.
We also change return type of function nvmet_file_ns_revalidate() from
int to void, since this function does not return any meaning value.
Signed-off-by: Chaitanya Kulkarni <kch@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Invert the check for discovery subsystem type to allow for additional
discovery subsystem types.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Add a helper function to determine if a given subsystem is a discovery
subsystem.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Chaitanya Kulkarni <kch@nvidia.com>
Reviewed-by: Himanshu Madhani <himanshu.madhani@oracle.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Some transports, such as RDMA, would like to set the queue size
according to device/port/ctrl characteristics. Add a new nvmet transport
op that is called during ctrl initialization. This will not effect
transports that don't implement this option.
Reviewed-by: Chaitanya Kulkarni <kch@nvidia.com>
Signed-off-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The target core code never needs the host-side nvme_ctrl structure.
Open code two uses of nvmet_is_passthru_req in passthru.c, and then
switch the helpers used by the core to return bool. Also rename the
fuctions to better match their usage:
nvmet_passthru_ctrl -> nvmet_is_passthru_subsys
nvmet_req_passthru_ctrl -> nvmet_is_passthru_req
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
For a passthru controller make cap initialization dependent on the cap of
the passthru controller, given that multiple Command Set support needs
to be supported by the underlying controller. For that move the
initialization of CAP later so that it can use the fully initialized
nvmet_ctrl structure.
Fixes: ab5d0b38c0 (nvmet: add Command Set Identifier support)
Signed-off-by: Adam Manzanares <a.manzanares@samsung.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
[hch: refactored the code a bit to keep it more contained in passthru.c]
Signed-off-by: Christoph Hellwig <hch@lst.de>
-----BEGIN PGP SIGNATURE-----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=D6dS
-----END PGP SIGNATURE-----
Merge tag 'for-5.14/drivers-2021-06-29' of git://git.kernel.dk/linux-block
Pull block driver updates from Jens Axboe:
"Pretty calm round, mostly just NVMe and a bit of MD:
- NVMe updates (via Christoph)
- improve the APST configuration algorithm (Alexey Bogoslavsky)
- look for StorageD3Enable on companion ACPI device
(Mario Limonciello)
- allow selecting the network interface for TCP connections
(Martin Belanger)
- misc cleanups (Amit Engel, Chaitanya Kulkarni, Colin Ian King,
Christoph)
- move the ACPI StorageD3 code to drivers/acpi/ and add quirks
for certain AMD CPUs (Mario Limonciello)
- zoned device support for nvmet (Chaitanya Kulkarni)
- fix the rules for changing the serial number in nvmet
(Noam Gottlieb)
- various small fixes and cleanups (Dan Carpenter, JK Kim,
Chaitanya Kulkarni, Hannes Reinecke, Wesley Sheng, Geert
Uytterhoeven, Daniel Wagner)
- MD updates (Via Song)
- iostats rewrite (Guoqing Jiang)
- raid5 lock contention optimization (Gal Ofri)
- Fall through warning fix (Gustavo)
- Misc fixes (Gustavo, Jiapeng)"
* tag 'for-5.14/drivers-2021-06-29' of git://git.kernel.dk/linux-block: (78 commits)
nvmet: use NVMET_MAX_NAMESPACES to set nn value
loop: Fix missing discard support when using LOOP_CONFIGURE
nvme.h: add missing nvme_lba_range_type endianness annotations
nvme: remove zeroout memset call for struct
nvme-pci: remove zeroout memset call for struct
nvmet: remove zeroout memset call for struct
nvmet: add ZBD over ZNS backend support
nvmet: add Command Set Identifier support
nvmet: add nvmet_req_bio put helper for backends
nvmet: add req cns error complete helper
block: export blk_next_bio()
nvmet: remove local variable
nvmet: use nvme status value directly
nvmet: use u32 type for the local variable nsid
nvmet: use u32 for nvmet_subsys max_nsid
nvmet: use req->cmd directly in file-ns fast path
nvmet: use req->cmd directly in bdev-ns fast path
nvmet: make ver stable once connection established
nvmet: allow mn change if subsys not discovered
nvmet: make sn stable once connection was established
...
NVMe TP 4053 – Zoned Namespaces (ZNS) allows host software to
communicate with a non-volatile memory subsystem using zones for NVMe
protocol-based controllers. NVMeOF already support the ZNS NVMe
Protocol compliant devices on the target in the passthru mode. There
are generic zoned block devices like Shingled Magnetic Recording (SMR)
HDDs that are not based on the NVMe protocol.
This patch adds ZNS backend support for non-ZNS zoned block devices as
NVMeOF targets.
This support includes implementing the new command set NVME_CSI_ZNS,
adding different command handlers for ZNS command set such as NVMe
Identify Controller, NVMe Identify Namespace, NVMe Zone Append,
NVMe Zone Management Send and NVMe Zone Management Receive.
With the new command set identifier, we also update the target command
effects logs to reflect the ZNS compliant commands.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Damien Le Moal <damien.lemoal@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
NVMe TP 4056 allows controllers to support different command sets.
NVMeoF target currently only supports namespaces that contain
traditional logical blocks that may be randomly read and written. In
some applications there is a value in exposing namespaces that contain
logical blocks that have special access rules (e.g. sequentially write
required namespace such as Zoned Namespace (ZNS)).
In order to support the Zoned Block Devices (ZBD) backend, controllers
need to have support for ZNS Command Set Identifier (CSI).
In this preparation patch, we adjust the code such that it can now
support the default command set identifier. We update the namespace data
structure to store the CSI value which defaults to NVME_CSI_NVM
that represents traditional logical blocks namespace type.
The CSI support is required to implement the ZBD backend for NVMeOF
with host side NVMe ZNS interface, since ZNS commands belong to
the different command set than the default one.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In current code there exists two backends which are using inline bio
optimization, that adds a duplicate code for freeing the bio.
For Zoned Block Device backend we also use the same optimzation and it
will lead to having duplicate code in the three backends: generic
bdev, passsthru, and generic zns.
Add a helper function to avoid duplicate code and update the respective
backends.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Damien Le Moal <damien.lemoal@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We report error and complete the request when identify cns value is not
handled in nvmet_execute_identify(). This error reporting is also needed
for Zone Block Device backend for NVMeOF target.
Add a helper nvmet_req_cns_error_compplete() to report an error and
complete the request when idenitfy command cns not handled value.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Damien Le Moal <damien.lemoal@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Use u32 type for the nsid_max member of the nvmet_subsys structure.
This avoids the type confusion when updating the subsys->nax_nsid from
ns->nsid. This also matches the nvmet_ns->nsid member.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Once some host has connected to the target, make sure that the serial
number is stable and cannot be changed.
Reviewed-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Signed-off-by: Noam Gottlieb <ngottlieb@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
According to the NVM specification, the serial_number should be 20 bytes
(bytes 23:04 of the Identify Controller data structure), and should
contain only ASCII characters.
In accordance, the serial_number size is changed to 20 bytes and before
any attempt to store a new value in serial_number we check that the
input is valid - i.e. contains only ASCII characters, is not empty and
does not exceed 20 bytes.
Signed-off-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Signed-off-by: Noam Gottlieb <ngottlieb@nvidia.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Controller teardown flow may take some time in case it has many I/O
queues, and the host may not send us keep-alive during this period.
Hence reset the traffic based keep-alive timer so we don't trigger
a controller teardown as a result of a keep-alive expiration.
Reported-by: Yi Zhang <yi.zhang@redhat.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Tested-by: Yi Zhang <yi.zhang@redhat.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When handling rw commands, for inline bio case we only consider
transfer size. This works well when req->sg_cnt fits into the
req->inline_bvec, but it will result in the warning in
__bio_add_page() when req->sg_cnt > NVMET_MAX_INLINE_BVEC.
Consider an I/O size 32768 and first page is not aligned to the page
boundary, then I/O is split in following manner :-
[ 2206.256140] nvmet: sg->length 3440 sg->offset 656
[ 2206.256144] nvmet: sg->length 4096 sg->offset 0
[ 2206.256148] nvmet: sg->length 4096 sg->offset 0
[ 2206.256152] nvmet: sg->length 4096 sg->offset 0
[ 2206.256155] nvmet: sg->length 4096 sg->offset 0
[ 2206.256159] nvmet: sg->length 4096 sg->offset 0
[ 2206.256163] nvmet: sg->length 4096 sg->offset 0
[ 2206.256166] nvmet: sg->length 4096 sg->offset 0
[ 2206.256170] nvmet: sg->length 656 sg->offset 0
Now the req->transfer_size == NVMET_MAX_INLINE_DATA_LEN i.e. 32768, but
the req->sg_cnt is (9) > NVMET_MAX_INLINE_BIOVEC which is (8).
This will result in the following warning message :-
nvmet_bdev_execute_rw()
bio_add_page()
__bio_add_page()
WARN_ON_ONCE(bio_full(bio, len));
This scenario is very hard to reproduce on the nvme-loop transport only
with rw commands issued with the passthru IOCTL interface from the host
application and the data buffer is allocated with the malloc() and not
the posix_memalign().
Fixes: 73383adfad ("nvmet: don't split large I/Os unconditionally")
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
According to the NVM specifications, the model number size should be
40 bytes (bytes 63:24 of the Identify Controller data structure).
Therefore, any attempt to store a value into model_number which
exceeds 40 bytes should return an error.
Reviewed-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Signed-off-by: Noam Gottlieb <ngottlieb@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The function nvmet_ctrl_find_get() accepts out pointer to nvmet_ctrl
structure. This function returns the same error value from two places
that is :- NVME_SC_CONNECT_INVALID_PARAM | NVME_SC_DNR.
Move this to the caller so we can change the return type to nvmet_ctrl.
Now that we can changed the return type, instead of taking out pointer
to the nvmet_ctrl structure remove that function parameter and return
the valid nvmet_ctrl pointer on success and NULL on failure.
Also, add and rename the goto labels for more readability with comments.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In nvmet_check_ctrl_status() cmd can be derived from nvmet_req. Remove
the local variable cmd in the nvmet_check_ctrl_status() and function
parameter cmd for nvmet_check_ctrl_status(). Derive the cmd value from
req parameter in the nvmet_check_ctrl_status().
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In case we have already established connection to nvmf target, it
shouldn't be allowed to change the model_number. E.g. if someone will
identify ctrl and get model_number of "my_model" later on will change
the model_numbel via configfs to "my_new_model" this will break the NVMe
specification for "Get Log Page – Persistent Event Log" that refers to
Model Number as: "This field contains the same value as reported in the
Model Number field of the Identify Controller data structure, bytes
63:24."
Although it doesn't mentioned explicitly that this field can't be
changed, we can assume it.
So allow setting this field only once: using configfs or in the first
identify ctrl operation.
Signed-off-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Just like what we have to get the passthru ctrl from the req, add an
helper to get the subsystem associated with the nvmet_req() instead
of open coding the chain of structures.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In the NVMeOF block device backend, file backend, and passthru backend
we reject and report the commands if opcode is not handled.
Add an helper and use it in block device backend to keep the code
and error message uniform.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The six callers of nvmet_find_namespace() duplicate the error log page
update and status setting code for each call on failure.
All callers are nvmet requests based functions, so we can pass req
to the nvmet_find_namesapce() & derive ctrl from req, that'll allow us
to update the error log page in nvmet_find_namespace(). Now that we
pass the request we can also get rid of the local variable in
nvmet_find_namespace() and use the req->ns and return the error code.
Replace the ctrl parameter with nvmet_req for nvmet_find_namespace(),
centralize the error log page update for non allocated namesapces, and
return uniform error for non-allocated namespace.
The nvmet_find_namespace() takes nsid parameter which is from NVMe
commands structures such as get_log_page, identify, rw and common. All
these commands have same offset for the nsid field.
Derive nsid from req->cmd->common.nsid) & remove the extra parameter
from the nvmet_find_namespace().
Lastly now we associate the ns to the req parameter that we pass to the
nvmet_find_namespace(), rename nvmet_find_namespace() to
nvmet_req_find_ns().
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In this preparation patch, we add helpers to convert lbas to sectors &
sectors to lba. This is needed to eliminate code duplication in the ZBD
backend.
Use these helpers in the block device backend.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Damien Le Moal <damien.lemoal@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
remove unused cqs from nvmet_ctrl struct
this will reduce the allocated memory.
Signed-off-by: Amit <amit.engel@dell.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In nvmet_passthru_execute_cmd() which is a high frequency function
it uses bio_alloc() which leads to memory allocation from the fs pool
for each I/O.
For NVMeoF nvmet_req we already have inline_bvec allocated as a part of
request allocation that can be used with preallocated bio when we
already know the size of request before bio allocation with bio_alloc(),
which we already do.
Introduce a bio member for the nvmet_req passthru anon union. In the
fast path, check if we can get away with inline bvec and bio from
nvmet_req with bio_init() call before actually allocating from the
bio_alloc().
This will be useful to avoid any new memory allocation under high
memory pressure situation and get rid of any extra work of
allocation (bio_alloc()) vs initialization (bio_init()) when
transfer len is < NVMET_MAX_INLINE_DATA_LEN that user can configure at
compile time.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Logan Gunthorpe <logang@deltatee.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
NVMeOF controller in the passsthru mode is capable of handling wide set
of I/O commands including vender specific passhtru io comands.
The vendor specific I/O commands are used to read the large drive
logs and can take longer than default NVMe commands, i.e. for
passthru requests the timeout value may differ from the passthru
controller's default timeout values (nvme-core:io_timeout).
Add a configfs attribute so that user can set the io timeout values.
In case if this configfs value is not set nvme_alloc_request() will set
the NVME_IO_TIMEOUT value when request queuedata is NULL.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
NVMeOF controller in the passsthru mode is capable of handling wide set
of admin commands including vender specific passhtru admin comands.
The vendor specific admin commands are used to read the large drive
logs and can take longer than default NVMe commands, i.e. for
passthru requests the timeout value may differ from the passthru
controller's default timeout values (nvme-core:admin_timeout).
Add a configfs attribute so that user can set the admin timeout values.
In case if this configfs value is not set nvme_alloc_request() will set
the ADMIN_TIMEOUT value when request queuedata is NULL.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
A user may modify the kato by a set features cmd. To properly deal
with races or a kato value of 0 (no keep alive enabled) change
nvmet_set_feat_kato to first disable the timer, then set the value
and then re-enable the timer.
Signed-off-by: Amit Engel <amit.engel@dell.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When CONFIG_NVME_TARGET_PASSTHRU as 'passthru' directory will
be added to each subsystem. The directory is similar to a namespace
and has two attributes: device_path and enable. The user must set the
path to the nvme controller's char device and write '1' to enable the
subsystem to use passthru.
Any given subsystem is prevented from enabling both a regular namespace
and the passthru device. If one is enabled, enabling the other will
produce an error.
Signed-off-by: Logan Gunthorpe <logang@deltatee.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
This patch adds helper functions which are used in the NVMeOF configfs
when the user is configuring the passthru subsystem. Here we ensure
that only one subsys is assigned to each nvme_ctrl by using an xarray
on the cntlid.
The subsystem's version number is overridden by the passed through
controller's version. However, if that version is less than 1.2.1,
then we bump the advertised version to that and print a warning
in dmesg.
Based-on-a-patch-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Logan Gunthorpe <logang@deltatee.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Add passthru command handling capability for the NVMeOF target and
export passthru APIs which are used to integrate passthru
code with nvmet-core.
The new file passthru.c handles passthru cmd parsing and execution.
In the passthru mode, we create a block layer request from the nvmet
request and map the data on to the block layer request.
Admin commands and features are on an allow list as there are a number
of each that don't make too much sense with passthrough. We use an
allow list such that new commands can be considered before being blindly
passed through. In both cases, vendor specific commands are always
allowed.
We also reject reservation IO commands as the underlying device cannot
differentiate between multiple hosts behind a fabric.
Based-on-a-patch-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Logan Gunthorpe <logang@deltatee.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Replace has_keyed_sgls and metadata_support booleans with a flags member
that will be used for adding more features in the future.
Signed-off-by: Max Gurtovoy <maxg@mellanox.com>
Reviewed-by: Himanshu Madhani <himanshu.madhani@oracle.com>
Reviewed-by: Israel Rukshin <israelr@mellanox.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Allocate the metadata SGL buffers and set metadata fields for the
request. Then create a block IO request for the metadata from the
protection SG list.
Signed-off-by: Israel Rukshin <israelr@mellanox.com>
Signed-off-by: Max Gurtovoy <maxg@mellanox.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Expose the namespace metadata format when PI is enabled. The user needs
to enable the capability per subsystem and per port. The other metadata
properties are taken from the namespace/bdev.
Usage example:
echo 1 > /config/nvmet/subsystems/${NAME}/attr_pi_enable
echo 1 > /config/nvmet/ports/${PORT_NUM}/param_pi_enable
Signed-off-by: Israel Rukshin <israelr@mellanox.com>
Signed-off-by: Max Gurtovoy <maxg@mellanox.com>
Reviewed-by: James Smart <james.smart@broadcom.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The function doesn't check only the data length, because the transfer
length includes also the metadata length in some cases. This is
preparation for adding metadata (T10-PI) support.
Signed-off-by: Israel Rukshin <israelr@mellanox.com>
Signed-off-by: Max Gurtovoy <maxg@mellanox.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Martin K. Petersen <martin.petersen@oracle.com>
Reviewed-by: James Smart <james.smart@broadcom.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The function doesn't add the metadata length (only data length is
calculated). This is preparation for adding metadata (T10-PI) support.
Signed-off-by: Israel Rukshin <israelr@mellanox.com>
Reviewed-by: Max Gurtovoy <maxg@mellanox.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Martin K. Petersen <martin.petersen@oracle.com>
Reviewed-by: James Smart <james.smart@broadcom.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Fill those namespace fields from the block device format for adding
metadata (T10-PI) over fabric support with block devices.
Signed-off-by: Israel Rukshin <israelr@mellanox.com>
Signed-off-by: Max Gurtovoy <maxg@mellanox.com>
Reviewed-by: Martin K. Petersen <martin.petersen@oracle.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
This patch adds a wrapper helper to indicate size change in the bdev &
file-backed namespace when revalidating ns. This helper is needed in
order to minimize code repetition in the next patch for configfs.c and
existing admin-cmd.c.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimbeg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Add support for detecting capacity changes on nvmet blockdev and file
backed namespaces. This allows for emulating and testing online resizing
of nvme devices and filesystems on top.
Signed-off-by: Anthony Iliopoulos <ailiop@suse.com>
[chaitanya: Fix comments posted on V1]
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
[hch: reuse code a bit more]
Signed-off-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
Some transports, such as RDMA, would like to set the Maximum Data
Transfer Size (MDTS) according to device/port/ctrl characteristics.
This will enable the transport to set the optimal MDTS according to
controller needs and device capabilities. Add a new nvmet transport
op that is called during ctrl identification. This will not effect
transports that don't implement this option. The return value of the new
op is according to the NVMe spec definition for MDTS.
Reviewed-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Max Gurtovoy <maxg@mellanox.com>
Signed-off-by: Israel Rukshin <israelr@mellanox.com>
This patch adds a new target subsys attribute which allows user to
optionally specify model name which then used in the
nvmet_execute_identify_ctrl() to fill up the nvme_id_ctrl structure.
The default value for the model is set to "Linux" for backward
compatibility.
Reviewed-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Mark Ruijter <MRuijter@onestopsystems.com>
[chaitanya.kulkarni@wdc.com
*Use macro for default model, coding style fixes.
*Use RCU for accessing model in for configfs and in
nvmet_execute_identify_ctrl().
]
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Keith Busch <kbusch@kernel.org>