Errors were summed improperly, some stats were missing.
Signed-off-by: Eliezer Tamir <eliezert@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The configuration of RX filtering needed the following corrections:
Drop flags need to be set per Rx queue.
Have to tell the microcode to collect drop stats, and properly wait
for them to complete when going down.
Sometimes we failed to detect proper completion due to a logical error
in the wait loop.
Signed-off-by: Eliezer Tamir <eliezert@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Properly protect PHY access between two devices on the same board with
a HW lock.
Use GPIO to clear all previous configurations before changing link
parameters.
Shut down the external PHY in case of fan failure.
Reducing the MDC/MDIO clock to 2.5MHz due to problems with some
devices.
Resolve the flow control response according to autoneg with external
PHY.
Unmasking all PHY interrupts in single write to prevent a race in the
interrupts order.
LASI indication fixes to work with peculiarities of PHYs.
Disable MAC RX to avoid a HW bug when closing the MAC under traffic.
Disable parallel detection on HiGig due to HW limitation.
Updating the shared memory structure to work with the current
bootcode.
Signed-off-by: Eliezer Tamir <eliezert@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Correct PCI-E info printed by init_one()
In one case it failed to free the netdev.
Signed-off-by: Eliezer Tamir <eliezert@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>