As these are rather late in the cycle, they may sneak over into 4.12.
There is a fix for a regression caused by another fix (hid sensors
hardware seems to vary a lot in how various corner cases are handled).
* ad7303
- fix channel description. Numeric values were being passed as characters
presumably leading to garbage from the userspace interface.
* as3935
- the write data macro was wrong so fix it.
* bmp280
- incorrect handling of negative values as being unsigned broke humidity
calculation.
* hid-sensor
- Restore the poll and hysteresis values after resume as some hardware
doesn't do it.
* stm32-trigger
- buglet in reading the sampling frequency
-----BEGIN PGP SIGNATURE-----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=H5KS
-----END PGP SIGNATURE-----
Merge tag 'iio-fixes-for-4.11e' of git://git.kernel.org/pub/scm/linux/kernel/git/jic23/iio into staging-next
Jonathan writes:
Fifth set of IIO fixes for the 4.11 cycle.
As these are rather late in the cycle, they may sneak over into 4.12.
There is a fix for a regression caused by another fix (hid sensors
hardware seems to vary a lot in how various corner cases are handled).
* ad7303
- fix channel description. Numeric values were being passed as characters
presumably leading to garbage from the userspace interface.
* as3935
- the write data macro was wrong so fix it.
* bmp280
- incorrect handling of negative values as being unsigned broke humidity
calculation.
* hid-sensor
- Restore the poll and hysteresis values after resume as some hardware
doesn't do it.
* stm32-trigger
- buglet in reading the sampling frequency
This change undo the change done by 'commit 3bec247474
("iio: hid-sensor-trigger: Change get poll value function order to avoid
sensor properties losing after resume from S3")' as this breaks some
USB/i2c sensor hubs.
Instead of relying on HW for restoring poll and hysteresis, driver stores
and restores on resume (S3). In this way user space modified settings are
not lost for any kind of sensor hub behavior.
In this change, whenever user space modifies sampling frequency or
hysteresis driver will get the feature value from the hub and store in the
per device hid_sensor_common data structure. On resume callback from S3,
system will set the feature to sensor hub, if user space ever modified the
feature value.
Fixes: 3bec247474 ("iio: hid-sensor-trigger: Change get poll value function order to avoid sensor properties losing after resume from S3")
Reported-by: Ritesh Raj Sarraf <rrs@researchut.com>
Tested-by: Ritesh Raj Sarraf <rrs@researchut.com>
Tested-by: Song, Hongyan <hongyan.song@intel.com>
Cc: stable@vger.kernel.org
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
When system bootup without get sensor property, set sensor
property will be fail.
If no get_feature operation done before set_feature, the sensor
properties will all be the initialized value, which is not the
same with sensor real properties. When set sensor property it will
write back to sensor the changed perperty data combines with other
sensor properties data, it is not right and may be dangerous.
In order to get all sensor properties, choose to read one of the sensor
properties(no matter read any sensor peroperty, driver will get all
the peroperties and return the requested one).
Fixes: 73c6768b71 ("iio: hid-sensors: Common attribute and trigger")
Signed-off-by: Song Hongyan <hongyan.song@intel.com>
Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Environmental humidity sensor is a hid defined sensor,
it shows raw humidity measurement of air.
More information can be found in:
http://www.usb.org/developers/hidpage/HUTRR39b.pdf
According to IIO ABI definition, humidityrelative data output unit is
milli percent. Add the unit convert from percent to milli percent.
Signed-off-by: Song Hongyan <hongyan.song@intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Scale value include two parts: unit conversion and exponent conversion.
Add gravity unit convert table to fix gravity sensor scale value not
right issue.
Signed-off-by: Song Hongyan <hongyan.song@intel.com>
Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Environmental temperature sensor is a hid defined sensor,
it measures temperature.
More information can be found in:
http://www.usb.org/developers/hidpage/HUTRR39b.pdf
According to IIO ABI definition, IIO_TEMP data output unit is
milli degrees Celsius. Add the unit convert from degree to milli degree.
Signed-off-by: Song Hongyan <hongyan.song@intel.com>
Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Added timestamp channel. With this change, each sample has a timestamp.
This timestamp can be from the sensor hub when present or local kernel
timestamp. HID sensors can send timestamp with input data using usage id
HID_USAGE_SENSOR_TIME_TIMESTAMP. This timestamp value is converted to
nano seconds before pushing this sample to the iio core.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
While testing, it was observed that on some platforms the scale value
from iio sysfs for gyroscope is always 0 (E.g. Yoga 260). This results
in the final angular velocity component values to be zeros.
This is caused by insufficient precision of scale value displayed in sysfs.
If the precision is changed to nano from current micro, then this is
sufficient to display the scale value on this platform.
Since this can be a problem for all other HID sensors, increase scale
precision of all HID sensors to nano from current micro.
Results on Yoga 260:
name scale before scale now
--------------------------------------------
gyro_3d 0.000000 0.000000174
als 0.001000 0.001000000
magn_3d 0.000001 0.000001000
accel_3d 0.000009 0.000009806
Signed-off-by: Song Hongyan <hongyan.song@intel.com>
Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Neither sample frequency value nor hysteresis value can be set to be a
negative number, check and return "Invalid argument" if they are negative.
If not do this change, sample_frequency will be set into some unknown
value, read hysteresis value after write negative number will return
"Invalid argument".
Signed-off-by: Song Hongyan <hongyan.song@intel.com>
Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
According to IIO ABI definition, IIO_PRESSURE data output unit is
kilopascal:
http://lxr.free-electrons.com/source/Documentation/ABI/testing/sysfs-bus-iio
This patch fix output unit of HID pressure sensor IIO driver from pascal to
kilopascal to follow IIO ABI definition.
Signed-off-by: Kweh, Hock Leong <hock.leong.kweh@intel.com>
Reviewed-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Current API only allows setting one offset in the field. This API
is extended to set multiple offsets in the field report.
Also update parameters in the users of this API.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Reviewed-by: Jonathan Cameron <jic23@kernel.org>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Some hid sensor feature report can contain more than one reports.
This API can now support receiving multiple values from the feature
report.
Also update the parameters in the users of this API.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Acked-by: Jonathan Cameron <jic23@kernel.org>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This fixes the following sparse warning:
CHECK drivers/iio/common/hid-sensors/hid-sensor-attributes.c
drivers/iio/common/hid-sensors/hid-sensor-attributes.c:346:5: warning:
symbol 'hid_sensor_get_reporting_interval' was not declared. Should it be static?
Signed-off-by: Daniel Baluta <daniel.baluta@intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Move the 'static' keyword to beginning of definition to silence the
following compilation warning:
drivers/iio/common/hid-sensors/hid-sensor-attributes.c:34:1: warning: ‘static’ is not at beginning of declaration [-Wold-style-declaration]
Signed-off-by: Sachin Kamat <sachin.kamat@samsung.com>
Cc: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
For PROP_REPORT_INTERVAL, the spec does not mandate the presence
of the report interval unit in the feature report and expects the
default unit of measure to be used as milliseconds.
Currently, when the unit is not present, it gets set as zero leading
to issues in sampling frequency.
This patch sets the unit of measure to the default unit if it
is not defined by firmware.
Signed-off-by: Archana Patni <archana.patni@intel.com>
Signed-off-by: Subramony Sesha <subramony.sesha@intel.com>
Reviewed-by: Srinivas Pandruvada <srinivas.pandruvada@intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
The "i < " was missing in this condition.
Fixes: 5d02edfc39 ('iio: hid-sensors: Convert units and exponent')
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Added interface to get poll value in milli-seconds. This value is
changed by changing sampling frequency. This API allows clients
to wait for at least some poll milli seconds before reading a new sample.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
HID sensor hub specify a default unit and alternative units. This
along with unit exponent can be used adjust scale. This change
change HID sensor data units to IIO defined units for each
sensor type. So in this way user space can use a simply use:
"(data + offset) * scale" to get final result.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
The structure with common attributes for hid-sensors isn't specific
to the iio-subsystem, so rename it to hid_sensor_common.
Signed-off-by: Alexander Holler <holler@ahsoftware.de>
Acked-by: Jiri Kosina <jkosina@suse.cz>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
The stuff in hid-sensor-attributes.h is needed by every piece which
uses hid-sensor-hub and merging it into hid-sensor-hub.h makes it accessible
from outside the iio subdirectory.
Signed-off-by: Alexander Holler <holler@ahsoftware.de>
Acked-by: Jiri Kosina <jkosina@suse.cz>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This patch contains the common code, which is used by all HID sensors.
There are some common set of attributes, which every hid sensor
needs it. This patch contains all such attributes processing.
Also the trigger interface is common among all HID sensors. This
patch contains common trigger functions utilized by all HID sensors.
Signed-off-by: srinivas pandruvada <srinivas.pandruvada@intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>