Commit Graph

137 Commits

Author SHA1 Message Date
Matthias Kaehlcke
bf45ac18b7 thermal: cpu_cooling: Actually trace CPU load in thermal_power_cpu_get_power
The CPU load values passed to the thermal_power_cpu_get_power
tracepoint are zero for all CPUs, unless, unless the
thermal_power_cpu_limit tracepoint is enabled too:

  irq/41-rockchip-98    [000] ....   290.972410: thermal_power_cpu_get_power:
  cpus=0000000f freq=1800000 load={{0x0,0x0,0x0,0x0}} dynamic_power=4815

vs

  irq/41-rockchip-96    [000] ....    95.773585: thermal_power_cpu_get_power:
  cpus=0000000f freq=1800000 load={{0x56,0x64,0x64,0x5e}} dynamic_power=4959
  irq/41-rockchip-96    [000] ....    95.773596: thermal_power_cpu_limit:
  cpus=0000000f freq=408000 cdev_state=10 power=416

There seems to be no good reason for omitting the CPU load information
depending on another tracepoint. My guess is that the intention was to
check whether thermal_power_cpu_get_power is (still) enabled, however
'load_cpu != NULL' already indicates that it was at least enabled when
cpufreq_get_requested_power() was entered, there seems little gain
from omitting the assignment if the tracepoint was just disabled, so
just remove the check.

Fixes: 6828a4711f ("thermal: add trace events to the power allocator governor")
Signed-off-by: Matthias Kaehlcke <mka@chromium.org>
Reviewed-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Acked-by: Javi Merino <javi.merino@kernel.org>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2019-05-14 07:00:41 -07:00
Daniel Lezcano
72554a7509 thermal/drivers/cpu_cooling: Remove pointless field
The structure cpufreq_cooling_device provides a backpointer to the thermal
device but this one is used for a trace and to unregister. For the trace,
we don't really need this field and the unregister function as the same
pointer passed as parameter. Remove it.

Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2019-05-14 07:00:35 -07:00
Daniel Lezcano
0fac9e2f14 thermal/drivers/cpu_cooling: Add Software Package Data Exchange (SPDX)
For license auditing purpose, let's add the SPDX tag.

Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Acked-by: Philippe Ombredanne <pombredanne@nexb.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2019-05-14 07:00:35 -07:00
Daniel Lezcano
42cd9b0498 thermal/drivers/cpu_cooling: Fixup the header and copyright
The copyright format does not conform to the format requested by
Linaro: https://wiki.linaro.org/Copyright

Fix it.

Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2019-05-14 07:00:34 -07:00
Daniel Lezcano
3c74cbb8d0 thermal/drivers/cpu_cooling: Remove pointless test in power2state()
When the static power computation was removed, the test with the power
being negative was not removed. However, the substraction which was
responsible of the negative value was removed and the variable is now
an u32. A double reason to remove the test which does not make sense.

Fixes: 84fe2cab48 ("cpu_cooling: Drop static-power related stuff")
Cc: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2019-05-14 07:00:33 -07:00
Shaokun Zhang
e0fda7377d thermal: cpu_cooling: Remove unused cur_freq variable
The 'cur_freq' local variable became unused after commit 84fe2cab48
("cpu_cooling: Drop static-power related stuff"), let's remove it.

Cc: Amit Daniel Kachhap <amit.kachhap@gmail.com>
Cc: Viresh Kumar <viresh.kumar@linaro.org>
Cc: Javi Merino <javi.merino@kernel.org>
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Eduardo Valentin <edubezval@gmail.com>
Cc: Daniel Lezcano <daniel.lezcano@linaro.org>
Signed-off-by: Shaokun Zhang <zhangshaokun@hisilicon.com>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2019-03-18 22:11:06 +08:00
Amit Kucheria
bf78f133cd thermal: cpu_cooling: Clarify error message
Make it clear that it is a failure if the cpufreq driver was unable to
register as a cooling device. Makes it easier to find in logs and
grepping for words like fail, err, warn.

Signed-off-by: Amit Kucheria <amit.kucheria@linaro.org>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2019-02-05 15:50:13 -08:00
Viresh Kumar
84fe2cab48 cpu_cooling: Drop static-power related stuff
No one has used it for the last two and half years (since it was
introduced by commit c36cf07176 (thermal: cpu_cooling: implement the
power cooling device API), get rid of it.

Acked-by: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
2017-12-07 22:52:01 +01:00
Viresh Kumar
3ebb62ffc4 cpu_cooling: Keep only one of_cpufreq*cooling_register() helper
of_cpufreq_cooling_register() isn't used by anyone and so can be
removed, but then we would be left with two routines:
cpufreq_cooling_register() and of_cpufreq_power_cooling_register() that
would look odd.

Remove current implementation of of_cpufreq_cooling_register() and
rename of_cpufreq_power_cooling_register() as
of_cpufreq_cooling_register(). This simplifies lots of stuff.

Acked-by: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
2017-12-07 22:52:01 +01:00
Viresh Kumar
ba0966da20 cpu_cooling: Remove unused cpufreq_power_cooling_register()
It isn't used by anyone, drop it.

Acked-by: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
2017-12-07 22:52:01 +01:00
Viresh Kumar
f5f263fed6 cpu_cooling: Make of_cpufreq_power_cooling_register() parse DT
All the callers of of_cpufreq_power_cooling_register() have almost
identical code and it makes more sense to move that code into the helper
as its all about reading DT properties.

This got rid of lot of redundant code.

Acked-by: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
2017-12-07 22:52:01 +01:00
Arvind Yadav
b2fd708ffa thermal: cpu_cooling: pr_err() strings should end with newlines
pr_err() messages should end with a new-line to avoid other messages
being concatenated.

Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Acked-by: Javi Merino <javi.merino@kernel.org>
Signed-off-by: Arvind Yadav <arvind.yadav.cs@gmail.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2017-10-31 19:32:19 -07:00
Viresh Kumar
f19b1a1735 thermal: cpu_cooling: Replace kmalloc with kmalloc_array
Checkpatch reports following:

WARNING: Prefer kmalloc_array over kmalloc with multiply
+	cpufreq_cdev->freq_table = kmalloc(sizeof(*cpufreq_cdev->freq_table) * i,

Fix that.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2017-05-27 17:33:04 -07:00
Viresh Kumar
d72b401583 thermal: cpu_cooling: Rearrange struct cpufreq_cooling_device
This shrinks the size of the structure on arm64 by 8 bytes by avoiding
padding of 4 bytes at two places.

Also add missing doc comment for freq_table

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2017-05-27 17:33:02 -07:00
Viresh Kumar
cb1b631864 thermal: cpu_cooling: 'freq' can't be zero in cpufreq_state2power()
The frequency table shouldn't have any zero frequency entries and so
such a check isn't required. Though it would be better to make sure
'state' is within limits.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2017-05-27 17:32:59 -07:00
Viresh Kumar
53ca1ece60 thermal: cpu_cooling: don't store cpu_dev in cpufreq_cdev
'cpu_dev' is used by only one function, get_static_power(), and it
wouldn't be time consuming to get the cpu device structure within it.
This would help removing cpu_dev from struct cpufreq_cooling_device.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2017-05-27 17:32:55 -07:00
Viresh Kumar
da27f69d6a thermal: cpu_cooling: get_level() can't fail
The frequency passed to get_level() is returned by cpu_power_to_freq()
and it is guaranteed that get_level() can't fail.

Get rid of error code.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2017-05-27 17:32:52 -07:00
Viresh Kumar
81ee14da10 thermal: cpu_cooling: create structure for idle time stats
We keep two arrays for idle time stats and allocate memory for them
separately. It would be much easier to follow if we create an array of
idle stats structure instead and allocate it once.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2017-05-27 17:32:48 -07:00
Viresh Kumar
349d39dc57 thermal: cpu_cooling: merge frequency and power tables
The cpu_cooling driver keeps two tables:

- freq_table: table of frequencies in descending order, built from
  policy->freq_table.

- power_table: table of frequencies and power in ascending order, built
  from OPP table.

If the OPPs are used for the CPU device then both these tables are
actually built using the OPP core and should have the same frequency
entries. And there is no need to keep separate tables for this.

Lets merge them both.

Note that the new table is in descending order of frequencies and so the
'for' loops were required to be fixed at few places to make it work.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2017-05-27 17:32:44 -07:00
Viresh Kumar
ba76dd9ddd thermal: cpu_cooling: get rid of 'allowed_cpus'
'allowed_cpus' is a copy of policy->related_cpus and can be replaced by
it directly. At some places we are only concerned about online CPUs and
policy->cpus can be used there.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2017-05-27 17:32:41 -07:00
Viresh Kumar
02bacb21c6 thermal: cpu_cooling: OPPs are registered for all CPUs
The OPPs are registered for all CPUs of a cpufreq policy now and we
don't need to run the loop in build_dyn_power_table(). Just check for
the policy->cpu and we should be fine.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2017-05-27 17:32:37 -07:00
Viresh Kumar
b12b651949 thermal: cpu_cooling: store cpufreq policy
The cpufreq policy can be used by the cpu_cooling driver, lets store it
in the cpufreq_cooling_device structure.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2017-05-27 17:32:33 -07:00
Viresh Kumar
55d8529313 cpufreq: create cpufreq_table_count_valid_entries()
We need such a routine at two places already, lets create one.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2017-05-27 17:32:28 -07:00
Viresh Kumar
4d753aa7b6 thermal: cpu_cooling: use cpufreq_policy to register cooling device
The CPU cooling driver uses the cpufreq policy, to get clip_cpus, the
frequency table, etc. Most of the callers of CPU cooling driver's
registration routines have the cpufreq policy with them, but they only
pass the policy->related_cpus cpumask. The __cpufreq_cooling_register()
routine then gets the policy by itself and uses it.

It would be much better if the callers can pass the policy instead
directly. This also fixes a basic design flaw, where the policy can be
freed while the CPU cooling driver is still active.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2017-05-27 17:32:24 -07:00
Viresh Kumar
18f301c934 thermal: cpu_cooling: get rid of a variable in cpufreq_set_cur_state()
'cpu' is used at only one place and there is no need to keep a separate
variable for it.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2017-05-27 17:32:20 -07:00
Viresh Kumar
3e08b2df12 thermal: cpu_cooling: remove cpufreq_cooling_get_level()
There is only one user of cpufreq_cooling_get_level() and that already
has pointer to the cpufreq_cdev structure. It can directly call
get_level() instead and we can get rid of cpufreq_cooling_get_level().

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2017-05-27 17:32:04 -07:00
Viresh Kumar
04bdbdf93c thermal: cpu_cooling: replace cool_dev with cdev
Objects of "struct thermal_cooling_device" are named a bit
inconsistently. Lets use cdev everywhere.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2017-05-27 17:31:59 -07:00
Viresh Kumar
1dea432a67 thermal: cpu_cooling: Name cpufreq cooling devices as cpufreq_cdev
Objects of "struct cpufreq_cooling_device" are named a bit
inconsistently. Lets use cpufreq_cdev everywhere. Also note that the
lists containing such devices is renamed similarly too.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2017-05-27 17:31:55 -07:00
Viresh Kumar
fb8ea30821 thermal: cpu_cooling: rearrange globals
Just to make it look better.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2017-05-27 17:31:49 -07:00
Viresh Kumar
289d72afdd thermal: cpu_cooling: Avoid accessing potentially freed structures
After the lock is dropped, it is possible that the cpufreq_dev gets
freed before we call get_level() and that can cause kernel to crash.

Drop the lock after we are done using the structure.

Cc: 4.2+ <stable@vger.kernel.org> # 4.2+
Fixes: 02373d7c69 ("thermal: cpu_cooling: fix lockdep problems in cpu_cooling")
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2017-05-27 17:31:05 -07:00
Viresh Kumar
3ea3217cf9 thermal: cpu_cooling: Check OPP for errors
It is possible for dev_pm_opp_find_freq_exact() to return errors. It was
all fine earlier as dev_pm_opp_get_voltage() had a check within it to
check for invalid OPPs, but dev_pm_opp_put() doesn't have any similar
checks and the callers need to make sure OPP is valid before calling
them.

Also update the later dev_warn_ratelimited() to not print the error
message as the OPP is guaranteed to be valid now.

Reported-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2017-03-13 10:06:55 +08:00
Viresh Kumar
9aec9082bf thermal: cpu_cooling: Replace dev_warn with dev_err
There isn't much the user can do on seeing these warnings, as the
hardware is actually okay. dev_err suits much better here.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2017-03-13 10:06:47 +08:00
Matthew Wilcox
088db931e0 thermal: Fix potential deadlock in cpu_cooling
cooling_list_lock is covering not just cpufreq_dev_count, but also the
calls to cpufreq_register_notifier() and cpufreq_unregister_notifier().

Since cooling_list_lock is also used within cpufreq_thermal_notifier(),
lockdep reports a potential deadlock. Fix it by testing the condition
under cooling_list_lock and dropping the lock before calling
cpufreq_register_notifier(). And variable cpufreq_dev_count is removed
at the same time, because it's no longer needed after the fix.

Fixes: ae60608962 ("thermal: convert cpu_cooling to use an IDA")
Reported-and-Tested-by: Russell King <linux@armlinux.org.uk>
Signed-off-by: Matthew Wilcox <mawilcox@microsoft.com>
Acked-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2017-03-13 10:06:04 +08:00
Linus Torvalds
544a068f1f Merge branch 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux
Pull thermal management updates from Zhang Rui:

 - add thermal driver for R-Car Gen3 thermal sensors.

 - add thermal driver for ZTE' zx2967 family thermal sensors.

 - convert thermal ID allocation from IDR to IDA.

 - fix a possible NULL dereference in imx thermal driver.

 - fix a ti-soc-thermal driver dependency issue so that critical thermal
   control is still available when CPU_THERMAL is not defined.

 - update binding information for QorIQ thermal driver.

 - a couple of cleanups in thermal core, intel_powerclamp, exynos,
   dra752-thermal, mtk-thermal driver.

* 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux:
  powerpc/mpc85xx: Update TMU device tree node for T1023/T1024
  powerpc/mpc85xx: Update TMU device tree node for T1040/T1042
  dt-bindings: Update QorIQ TMU thermal bindings
  thermal: mtk_thermal: Staticise a number of data variables
  thermal: arm: dra752: Remove all TSHUT related definitions
  thermal: arm: dra752: Remove TSHUT configuration
  thermal: ti-soc-thermal: Remove CPU_THERMAL Dependency from TI_THERMAL
  thermal: imx: Fix possible NULL dereference.
  thermal: exynos: Remove parsing unused samsung,tmu_cal_mode property
  thermal: zx2967: add thermal driver for ZTE's zx2967 family
  thermal: use cpumask_var_t for on-stack cpu masks
  dt: bindings: add documentation for zx2967 family thermal sensor
  thermal/intel_powerclamp: Remove set-but-not-used variables
  thermal: rcar_gen3_thermal: Add R-Car Gen3 thermal driver
  thermal: rcar_gen3_thermal: Document the R-Car Gen3
  thermal: convert devfreq_cooling to use an IDA
  thermal: convert cpu_cooling to use an IDA
  thermal: convert clock cooling to use an IDA
  thermal core: convert ID allocation to IDA
2017-03-01 09:54:32 -08:00
Zhang Rui
6fefe19f58 Merge branches 'thermal-core', 'thermal-soc', 'thermal-intel' and 'ida-conversion' into next 2017-02-22 15:35:06 +08:00
Arnd Bergmann
d9cc34a6e1 thermal: use cpumask_var_t for on-stack cpu masks
Putting a bare cpumask structure on the stack produces a warning on
large SMP configurations:

drivers/thermal/cpu_cooling.c: In function 'cpufreq_state2power':
drivers/thermal/cpu_cooling.c:644:1: warning: the frame size of 1056 bytes is larger than 1024 bytes [-Wframe-larger-than=]
drivers/thermal/cpu_cooling.c: In function '__cpufreq_cooling_register':
drivers/thermal/cpu_cooling.c:898:1: warning: the frame size of 1104 bytes is larger than 1024 bytes [-Wframe-larger-than=]

The recommended workaround is to use cpumask_var_t, which behaves just like
a normal cpu mask in most cases, but turns into a dynamic allocation
when CONFIG_CPUMASK_OFFSTACK is set.

Signed-off-by: Arnd Bergmann <arnd@arndb.de>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2017-02-10 16:40:47 +08:00
Viresh Kumar
8a31d9d942 PM / OPP: Update OPP users to put reference
This patch updates dev_pm_opp_find_freq_*() routines to get a reference
to the OPPs returned by them.

Also updates the users of dev_pm_opp_find_freq_*() routines to call
dev_pm_opp_put() after they are done using the OPPs.

As it is guaranteed the that OPPs wouldn't get freed while being used,
the RCU read side locking present with the users isn't required anymore.
Drop it as well.

This patch also updates all users of devfreq_recommended_opp() which was
returning an OPP received from the OPP core.

Note that some of the OPP core routines have gained
rcu_read_{lock|unlock}() calls, as those still use RCU specific APIs
within them.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Chanwoo Choi <cw00.choi@samsung.com> [Devfreq]
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
2017-01-30 09:22:21 +01:00
Matthew Wilcox
ae60608962 thermal: convert cpu_cooling to use an IDA
thermal cpu cooling does not use the ability to look up pointers by ID,
so convert it from using an IDR to the more space-efficient IDA.

The cooling_cpufreq_lock was being used to protect cpufreq_dev_count as
well as the IDR.  Rather than keep the mutex to protect a single integer,
I expanded the scope of cooling_list_lock to also cover cpufreq_dev_count.
We could also convert cpufreq_dev_count into an atomic.

Signed-off-by: Matthew Wilcox <mawilcox@microsoft.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2017-01-04 12:47:28 +08:00
Hugh Kang
0744f1306f thermal: cpu_cooling: Fix wrong comment call function name
The last_load is updated not cpufreq_get_actual_power() function call
but cpufreq_get_requested_power() function call.

Signed-off-by: Inhyuk Kang <hugh.kang@lge.com>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Acked-by: Javi Merino <javi.merino@arm.com>
Acked-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2016-09-27 09:38:17 +08:00
Brendan Jackman
a305a4387a thermal: cpu_cooling: Fix NULL dereference in cpufreq_state2power
Currently all CPU cooling devices share a
`struct thermal_cooling_device_ops` instance. The thermal core uses the
presence of functions in this struct to determine if a cooling device
has a power model (see cdev_is_power_actor). cpu_cooling.c adds the
power model functions to the shared struct when a device is registered
with a power model.

Therefore, if a CPU cooling device is registered using
[of_]cpufreq_power_cooling_register, _all_ devices will be determined to
have a power model, including any registered with
[of_]cpufreq_cooling_register. This can result in cpufreq_state2power
being called on a device where dyn_power_table is NULL.

With this commit, instead of having a shared thermal_cooling_device_ops
which is mutated, we have two versions: one with the power functions and
one without.

Signed-off-by: Brendan Jackman <brendan.jackman@arm.com>
Cc: Amit Daniel Kachhap <amit.kachhap@gmail.com>
Cc: Viresh Kumar <viresh.kumar@linaro.org>
Cc: Javi Merino <javi.merino@arm.com>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Acked-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2016-08-19 21:32:18 +08:00
Rafael J. Wysocki
bb4b9933e2 Merge back earlier cpufreq changes for v4.8. 2016-06-13 23:33:17 +02:00
Viresh Kumar
f8bfc116ca cpufreq: Remove cpufreq_frequency_get_table()
Most of the callers of cpufreq_frequency_get_table() already have the
pointer to a valid 'policy' structure and they don't really need to go
through the per-cpu variable first and then a check to validate the
frequency, in order to find the freq-table for the policy.

Directly use the policy->freq_table field instead for them.

Only one user of that API is left after above changes, cpu_cooling.c and
it accesses the freq_table in a racy way as the policy can get freed in
between.

Fix it by using cpufreq_cpu_get() properly.

Since there are no more users of cpufreq_frequency_get_table() left, get
rid of it.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Acked-by: Javi Merino <javi.merino@arm.com> (cpu_cooling.c)
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
2016-06-09 00:58:05 +02:00
Lukasz Luba
f840ab18bd thermal: cpu_cooling: fix improper order during initialization
The freq_table array is not populated before calling
thermal_of_cooling_register. The code which populates the freq table was
introduced in commit f6859014.
This should be done before registering new thermal cooling device.
The log shows effects of this wrong decision.
[    2.172614] cpu cpu1: Failed to get voltage for frequency 1984518656000: -34
[    2.220863] cpu cpu0: Failed to get voltage for frequency 1984524416000: -34

Cc: <stable@vger.kernel.org> # 3.19+
Fixes: f6859014c7 ("thermal: cpu_cooling: Store frequencies in descending order")
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Acked-by: Javi Merino <javi.merino@arm.com>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2016-06-01 22:21:19 +08:00
Javi Merino
a53b8394ec thermal: cpu_cooling: fix out of bounds access in time_in_idle
In __cpufreq_cooling_register() we allocate the arrays for time_in_idle
and time_in_idle_timestamp to be as big as the number of cpus in this
cpufreq device.  However, in get_load() we access this array using the
cpu number as index, which can result in an out of bound access.

Index time_in_idle{,_timestamp} using the index in the cpufreq_device's
allowed_cpus mask, as we do for the load_cpu array in
cpufreq_get_requested_power()

Reported-by: Nicolas Boichat <drinkcat@chromium.org>
Cc: Amit Daniel Kachhap <amit.kachhap@gmail.com>
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Eduardo Valentin <edubezval@gmail.com>
Tested-by: Nicolas Boichat <drinkcat@chromium.org>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2016-02-11 07:13:29 -08:00
Vaishali Thakkar
a71544cd93 thermal: cpu_cooling: Remove usage of devm functions
In the function cpufreq_get_requested_power, the memory allocated
for load_cpu is live within the function only. And after the
allocation it is immediately freed with devm_kfree. There is no
need to allocate memory for load_cpu with devm function so replace
devm_kcalloc with kcalloc and devm_kfree with kfree.

Signed-off-by: Vaishali Thakkar <vthakkar1994@gmail.com>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Acked-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2015-10-10 11:32:21 +08:00
Javi Merino
eba4f88d5a thermal: cpu_cooling: free power table on error or when unregistering
The power table is not being freed on error from cpufreq_cooling
register or when unregistering.  Free it.

Fixes: c36cf07176 ("thermal: cpu_cooling: implement the power cooling device API")
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2015-09-13 20:34:05 -07:00
Javi Merino
459ac37506 thermal: cpu_cooling: don't call kcalloc() under rcu_read_lock
build_dyn_power_table() allocates the power table while holding
rcu_read_lock.  kcalloc using GFP_KERNEL may sleep, so it can't be
called in an RCU read-side path.

Move the rcu protection to the part of the function that really needs
it: the part that handles the dev_pm_opp pointer received from
dev_pm_opp_find_freq_ceil().  In the unlikely case that there is an OPP
added to the cpu while this function is running, return -EAGAIN.

Fixes: c36cf07176 ("thermal: cpu_cooling: implement the power cooling device API")
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2015-09-13 20:33:17 -07:00
Viresh Kumar
1afb9c539d thermal/cpu_cooling: update policy limits if clipped_freq < policy->max
policy->max is the maximum allowed frequency defined by user and
clipped_freq is the maximum that thermal constraints allow.

If clipped_freq is lower than policy->max, then we need to readjust
policy->max.

But, if clipped_freq is greater than policy->max, we don't need to do
anything. We used to call cpufreq_verify_within_limits() in this case,
but it doesn't change anything in this case.

Lets skip this unnecessary call and write a comment that explains this.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2015-08-14 18:26:23 -07:00
Viresh Kumar
abcbcc25cb thermal/cpu_cooling: rename max_freq as clipped_freq in notifier
That's what it is for, lets name it properly.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2015-08-14 18:26:23 -07:00
Viresh Kumar
59f0d21883 thermal/cpu_cooling: rename cpufreq_val as clipped_freq
That's what it is for, lets name it properly.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2015-08-14 18:26:22 -07:00