This patch makes the private functions alloc_can_skb() and
alloc_can_err_skb() of the at91_can driver public and adapts all
drivers to use these. While making the patch I realized, that
the skb's are *not* setup consistently. It's now done as shown
below:
skb->protocol = htons(ETH_P_CAN);
skb->pkt_type = PACKET_BROADCAST;
skb->ip_summed = CHECKSUM_UNNECESSARY;
*cf = (struct can_frame *)skb_put(skb, sizeof(struct can_frame));
memset(*cf, 0, sizeof(struct can_frame));
The frame is zeroed out to avoid uninitialized data to be passed to
user space. Some drivers or library code did not set "pkt_type" or
"ip_summed". Also, "__constant_htons()" should not be used for
runtime invocations, as pointed out by David Miller.
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This patch allows the CAN controller driver to define the number of echo
skb's used for the local loopback (echo), as suggested by Kurt Van
Dijck, with the function:
struct net_device *alloc_candev(int sizeof_priv,
unsigned int echo_skb_max);
The CAN drivers have been adapted accordingly. For the ems_usb driver,
as suggested by Sebastian Haas, the number of echo skb's has been
increased to 10, which improves the transmission performance a lot.
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: Kurt Van Dijck <kurt.van.dijck@eia.be>
Signed-off-by: David S. Miller <davem@davemloft.net>
TI HECC (High End CAN Controller) module is found on many TI devices. It
has 32 hardware mailboxes with full implementation of CAN protocol 2.0B
with bus speeds up to 1Mbps. Specifications of the module are available
on TI web <http://www.ti.com>
Signed-off-by: Anant Gole <anantgole@ti.com>
Signed-off-by: David S. Miller <davem@davemloft.net>