The return value of devm_clk_get should in general be propagated to
upper layer. In this case the clk is optional, use the appropriate
wrapper instead of interpreting all errors as "The optional clk is not
available".
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Link: https://lore.kernel.org/r/20210923201113.398932-1-u.kleine-koenig@pengutronix.de
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
The ltc2947 is a high precision power and energy monitor with an
internal sense resistor supporting up to +/- 30A. Three internal no
Latency ADCs ensure accurate measurement of voltage and current, while
high-bandwidth analog multiplication of voltage and current provides
accurate power measurement in a wide range of applications. Internal or
external clocking options enable precise charge and energy measurements.
Signed-off-by: Nuno Sá <nuno.sa@analog.com>
Link: https://lore.kernel.org/r/20191021154115.319073-1-nuno.sa@analog.com
[groeck: Removed unnecessary checks when reading temperature and energy;
PAGE{0,1} -> LTC2947_PAGE_{0,1}]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>