Move the mid-layer's ->queuecommand() invocation from being locked
with the host lock to being unlocked to facilitate speeding up the
critical path for drivers who don't need this lock taken anyway.
The patch below presents a simple SCSI host lock push-down as an
equivalent transformation. No locking or other behavior should change
with this patch. All existing bugs and locking orders are preserved.
Additionally, add one parameter to queuecommand,
struct Scsi_Host *
and remove one parameter from queuecommand,
void (*done)(struct scsi_cmnd *)
Scsi_Host* is a convenient pointer that most host drivers need anyway,
and 'done' is redundant to struct scsi_cmnd->scsi_done.
Minimal code disturbance was attempted with this change. Most drivers
needed only two one-line modifications for their host lock push-down.
Signed-off-by: Jeff Garzik <jgarzik@redhat.com>
Acked-by: James Bottomley <James.Bottomley@suse.de>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
When number of NPIV ports created are greater than the xids
allocated per pool -- for eg., creating 255 NPIV ports on a
system with nr_cpu_ids of 32, with each pool containing 128
xids -- and then generating a link event - for eg.,
shutdown/no shutdown -- on the switch port causes the hang
with the following stack trace.
Call Trace:
schedule_timeout+0x19d/0x230
wait_for_common+0xc0/0x170
__cancel_work_timer+0xcf/0x1b0
fc_disc_stop+0x16/0x30 [libfc]
fc_lport_reset_locked+0x47/0x90 [libfc]
fc_lport_enter_reset+0x67/0xe0 [libfc]
fc_lport_disc_callback+0xbc/0xe0 [libfc]
fc_disc_done+0xa8/0xf0 [libfc]
fc_disc_timeout+0x29/0x40 [libfc]
run_workqueue+0xb8/0x140
worker_thread+0x96/0x110
kthread+0x96/0xa0
child_rip+0xa/0x20
Fix is to not cancel the disc_work if discovery is already
stopped, thus allowing lport state machine to restart and try
discovery again.
Signed-off-by: Bhanu Prakash Gollapudi <bprakash@broadcom.com>
Acked-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Incoming requests shouldn't require a local exchange if we're
just going to reply with one or two frames and don't expect
anything further. Don't allocate exchanges for such requests
until requested by the upper-layer protocol.
The sequence is always NULL for new requests, so remove
that as an argument to request handlers.
Also change the first argument to lport->tt.seq_els_rsp_send
from the sequence pointer to the received frame pointer, to
supply the exchange IDs and destination ID info.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
For incoming ELS and FCP requests, we often don't require an
exchange and sequence, however, sometimes we do. For those cases,
(primarily FCP requests for targets) add a function to set up
the exchange and sequence.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Add functions to fill in an FC header given a request header.
These reduces code lines in fc_lport and fc_rport and works
without an exchange/sequence assigned.
fc_fill_reply_hdr() fills a header for a final reply frame.
fc_fill_hdr() which is similar but allows specifying the
f_ctl parameter.
Add defines for F_CTL values FC_FCTL_REQ and FC_FCTL_RESP.
These can be used for most request and response sequences.
v2 of patch adds a line to copy the frame encapsulation
info from the received frame.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
To pave the way for eliminating exchanges from incoming requests,
add simple inline fc_frame_sid() and fc_frame_did() functions
which get the FC_IDs from the frame header. This can be almost
as efficient as getting them from the sequence/exchange.
Move ntohll, htonll, ntoh24 and hton24 to <scsi/fc_frame.h>
since we need them there and that's included by <scsi/libfc.h>
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The LOGO state hasn't been used in a while, except in a brief
transition to DELETE state while holding the rport mutex.
All port LOGO responses have been ignored as well as any timeout
if we don't get a response.
So this patch just removes LOGO state and simplifies the response handler.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When an exchange is received with a FIP encapsulation, we need
to know that the response must be sent via FIP and what the original
ELS opcode was. This becomes important for VN2VN mode, where we may
receive FLOGI or LOGO from several peer VN_ports, and the LS_ACC or
LS_RJT must be sent FIP-encapsulated with the correct sub-type.
Add a field to the struct fc_frame, fr_encaps, to indicate the
encapsulation values. That term is chosen to be neutral and
LLD-agnostic in case non-FCoE/FIP LLDs might find it useful.
The frame fr_encaps is transferred from the ingress frame to the
exchange by fc_exch_recv_req(), and back to the outgoing frame
by fc_seq_send().
This is taking the last byte in the skb->cb array. If needed,
we could combine the info in sof, eof, flags, and encaps
together into one field, but it'd be better to do that if
and when its needed.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The FIP proposal for VN_port to VN_port point-to-multipoint
operation requires a FLOGI be sent to each remote port.
The FLOGI is sent with the assigned S_ID and D_IDs of the
local and remote ports. This and the response get
FIP-encapsulated for Ethernet.
Add FLOGI state to the remote port state machine.
This will be skipped if not in point-to-multipoint mode.
To reduce a little duplication between PLOGI and FLOGI
response handling, added fc_rport_login_complete(), which
handles the parameters for the rdata struct.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
For VN_port to VN_port mode, the transport sets the port_id and
there's no lport FLOGI. This is similar to FC loop mode.
Add a point_to_multipoint flag that indicates the local port is in
point-to-multipoint mode. This skips FLOGI and discovery.
It also skips resetting the port_id on resets other than link down.
Add function fc_lport_set_local_id() that sets the local port_id.
This is called by libfcoe on behalf of the low-level driver
to set the port_id when the link comes up.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
For VN_port to VN_port mode, FIP will do discovery and needs a
way to find its state from the local port or discovery structure.
It seems that any other LLD that implements its own discovery
would also need something like this.
Replace disc->lport with disc->priv, and use container_of to
find the lport. We could use disc->priv for that, but
container_of is smaller and faster.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Add pre-zeroed space after the allocation for fc_rport_priv
for use by the lower-level driver.
This is primarily for VN2VN FIP mode, but could be used in
other ways someday.
The space required is specified in lport->rport_priv_size.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
To allow LLD to do lookups on rports without grabbing a mutex,
make them RCU-safe. The caller of lport->tt.rport_lookup will
have the choice of holding disc_mutex or the rcu_read_lock().
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Remote ports were restarting indefinitely after getting
rejects in PRLI.
Fix by adding a counter of restarts and limiting that with
the port login retry limit as well.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This patch somewhat combines two fixes to remote port handing in libfc.
The first problem was that rport work could be queued on a deleted
and freed rport. This is handled by not resetting rdata->event
ton NONE if the rdata is about to be deleted.
However, that fix led to the second problem, described by
Bhanu Gollapudi, as follows:
> Here is the sequence of events. T1 is first LOGO receive thread, T2 is
> fc_rport_work() scheduled by T1 and T3 is second LOGO receive thread and
> T4 is fc_rport_work scheduled by T3.
>
> 1. (T1)Received 1st LOGO in state Ready
> 2. (T1)Delete port & enter to RESTART state.
> 3. (T1)schdule event_work, since event is RPORT_EV_NONE.
> 4. (T1)set event = RPORT_EV_LOGO
> 5. (T1)Enter RESTART state as disc_id is set.
> 6. (T2)remember to PLOGI, and set event = RPORT_EV_NONE
> 6. (T3)Received 2nd LOGO
> 7. (T3)Delete Port & enter to RESTART state.
> 8. (T3)schedule event_work, since event is RPORT_EV_NONE.
> 9. (T3)Enter RESTART state as disc_id is set.
> 9. (T3)set event = RPORT_EV_LOGO
> 10.(T2)work restart, enter PLOGI state and issues PLOGI
> 11.(T4)Since state is not RESTART anymore, restart is not set, and the
> event is not reset to RPORT_EV_NONE. (current event is RPORT_EV_LOGO).
> 12. Now, PLOGI succeeds and fc_rport_enter_ready() will not schedule
> event_work, and hence the rport will never be created, eventually losing
> the target after dev_loss_tmo.
So, the problem here is that we were tracking the desire for
the rport be restarted by state RESTART, which was otherwise
equivalent to DELETE. A contributing factor is that we dropped
the lock between steps 6 and 10 in thread T2, which allows the
state to change, and we didn't completely re-evaluate then.
This is hopefully corrected by the following minor redesign:
Simplify the rport restart logic by making the decision to
restart after deleting the transport rport. That decision
is based on a new STARTED flag that indicates fc_rport_login()
has been called and fc_rport_logoff() has not been called
since then. This replaces the need for the RESTART state.
Only restart if the rdata is still in DELETED state
and only if it still has the STARTED flag set.
Also now, since we clear the event code much later in the
work thread, allow for the possibility that the rport may
have become READY again via incoming PLOGI, and if so,
queue another event to handle that.
In the problem scenario, the second LOGO received will
cause the LOGO event to occur again.
Reported-by: Bhanu Gollapudi <bprakash@broadcom.com>
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This patch creates a port_id member in struct fc_lport.
This allows libfc to just deal with fc_lport instances
instead of calling into the fc_host to get the port_id.
This change helps in only using symbols necessary for
operation from the libfc structures. libfc still needs
to change the fc_host_port_id() if the port_id changes
so the presentation layer (scsi_transport_fc) can provide
the user with the correct value, but libfc shouldn't
rely on the presentation layer for operational values.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
hton24(p + 3, value) would fail to compile because
p + 3[0] is not a valid expression.
Went ahead and converted hton24 and ntoh24 to inline
functions, which is better because the parameters
are evalutated only once.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When the kernel is configured for preemption, using smp_processor_id()
when preemption is enabled causes a warning backtrace and is wrong
since we could move off of that CPU as soon as we get the ID,
and we would be referencing the wrong CPU, and possibly an invalid one
if it could be hotswapped out.
Remove the fc_lport_get_stats() function and explicitly use per_cpu_ptr()
to get the statistics. Where preemption has been disabled by holding
a _bh lock continue to use smp_processor_id(), but otherwise use
get_cpu()/put_cpu().
In fcoe_recv_frame() also changed the cases where we return in the
middle to do a goto to the code which bumps ErrorFrames and does
a put_cpu(). Two of these cases didn't bump ErrorFrames before, but
doing so is harmless because they "can't happen", due to prior length
checks.
Also rearranged code in fcoe_recv_frame() to have only one call to
fc_exch_recv(). It's just as efficient and saves a call to put_cpu().
In fc_fcp.c, adjusted a FIXME comment for code which doesn't need fixing.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Add a member function pointer as get_lesb to libfc_function_template so LLD
can fill the LESB based on its own statistics. For fcoe, it fills the LESB
as a fcoe_fc_els_lesb struct according to FC-BB-5.
Signed-off-by: Yi Zou <yi.zou@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
FC-BB-5 Rev2.0, Clause 7.10 extends the FC-LS-3 LESB for FC-BB_E. We are
already tracking Link Failure Count so add the rest in this patch.
For VLinkFailureCount and MissDiscAdvCount, they are part of the per-cpu
fcoe_dev_stats. For SymbolErrorCount, ErroredBlockCount, and FCSErrorCount,
they are defined in IEEE 802.3-2008 and are per LLD. They are expected to
come from LLD.
Signed-off-by: Yi Zou <yi.zou@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Customers and certification tests have pointed out that we don't
show up on the switch management software as an initiator.
On some MDS switches 'show fcns database' command shows libfc
initiators as 'fcp' not 'fcp:init' like other initiators.
On others switches, I think the switch gets the features by doing a PRLI,
but it may be only certain models or under certain configurations.
Fix this by registering our FC4 features with the RFF_ID CT request
after local port login and after the RFT_ID.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This is to notify the LLD when an FC_ID is assigned to the local port.
The fnic driver needs to push the assigned FC_ID to firmware.
It currently does this by intercepting the FLOGI responses, and
in order to make that code more common with FIP and NPIV, it
makes more sense to wait until the local port has completely
handled the FLOGI or FDISC response. Also, when we fix
point-to-point FC_ID assignment, we'll need this callback as well.
Add a call to the libfc template, which is called whenever
the local port FC_ID is being assigned. It defaults to
fc_lport_set_fid(), supplied by libfc.
As additional benefit of this function, the LLD may determine
the MAC address that caused the change by looking at the received frame.
We also print the assigned port ID as long as it isn't 0.
Setting port ID to 0 happens often in reset while retrying FLOGI,
and would be uninteresting. This replaces the previous message
which didn't identify the host adapter instance.
patch v2 note: changed one word in a comment. "intercepted" -> "provided".
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This patch makes a variety of cleanup changes to all libfc files.
This patch adds kernel-doc headers to all functions lacking them
and attempts to better format existing headers. It also add kernel-doc
headers to structures.
This patch ensures that the current naming conventions for local ports,
remote ports and remote port private data is upheld in the following
manner.
struct instance (i.e. variable name)
--------------------------------------------------
fc_lport lport
fc_rport rport
fc_rport_libfc_priv rpriv
fc_rport_priv rdata
I also renamed dns_rp and ptp_rp to dns_rdata and ptp_rdata
respectively.
I used emacs 'indent-region' and 'tabify' on all libfc files
to correct spacing alignments.
I feel sorry for anyone attempting to review this patch.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This is the Open-FCoE implementation of the FC
passthrough support via bsg interface.
Passthrough support is added to both N_Ports and
VN_Ports.
Signed-off-by: Steve Ma <steve.ma@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Register the fc_host symbolic name as the symbolic port name
with the fabric name server.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Register the fc_host symbolic name as the symbolic node name
with the fabric name server.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
One could interpret FC-GS-5 to say that an explicit RNN_ID is required
before RSNN_NN is allowed to succeed, which is why RNN_ID was not obsoleted
along with RPN_ID acording to this document:
ftp://ftp.t11.org/t11/member/fc/gs-5/05-546v2.pdf
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
RPN_ID has been obsolete per FC-GS-5 for several years. The port name is
registered implicitly as part of FLOGI, and it is undesirable for ports to
change a registered port name using RPN_ID while logged into the fabric.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The FIP code in libfcoe needed several changes to support NPIV
1) dst_src_addr needs to be managed per-n_port-ID for FPMA fabrics with NPIV
enabled. Managing the MAC address is now handled in fcoe, with some slight
changes to update_mac() and a new get_src_addr() function pointer.
2) The libfc elsct_send() hook is used to setup FCoE specific response
handlers for FIP encapsulated ELS exchanges. This lets the FCoE specific
handling know which VN_Port the exchange is for, and doesn't require
tracking OX_IDs. It might be possible to roll back to the full FIP frame
in these, but for now I've just stashed the contents of the MAC address
descriptor in the skb context block for later use. Also, because
fcoe_elsct_send() just passes control on to fc_elsct_send(), all transmits
still come through the normal frame_send() path.
3) The NPIV changes added a mutex hold in the keep alive sending, the lport
mutex is protecting the vport list. We can't take a mutex from a timer,
so move the FIP keep alive logic to the link work struct.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
NPIV vports are managed in libfc by changing their virtual link state
when the parent N_Ports internal state changes. The vport link is only
online when the N_Port is in a ready state (logged into the fabric).
vport_state is updated as needed in this patch as well, currently the states
LINKDOWN, INITIALIZING, ACTIVE, DSIABLED, and NO_FABRIC_SUPP are used.
This also changes the fc_host port_state handling to differentiate between
LINKDOWN and OFFLINE.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Adds a function to create a new VN_Port instances, which share the EM
list with the N_Port, VN_Port lookup by fabric ID when responding to a new
request (otherwise the exchange lookup from the N_Ports EM list is trusted to
return an exchange with a cached lport value for the correct VN_Port),
a pointer to a fc_vport structure for VN_Ports, and flags to indicate if an
N_Port supports NPIV and if the switch/fabric allows it.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
I'd like to keep basic initialization together with allocation, which means
this can't just be a tail-call to scsi_host_alloc.
This is needed to create a generic libfc host allocation routine for NPIV
VN_Ports, which will share the exchange ID space (through sharing exchange
manager structures) with the parent lport. In order to clone the exchange
manager list when the lport is allocated, the list head must be initialized
earlier.
Also, update fnic to use the libfc_host_alloc so that later changes do not break
it. (contribution by Joe Eykholt)
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
include/scsi/libfc.h is currently loaded with common code
shared between libfc's sub-modules as well as shared between
libfc and fcoe. Previous patches attempted to move out
non-common code. This patch creates two files for common
libfc routines that will not be shared with fcoe, fnic or
any other LLDs.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This function is never used, let's remove it.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This patch moves all non-common routines and function prototypes
out of libfc.h and into the appropriate .c files. It makes these
routines 'static' when necessary and removes any unnecessary EXPORT_SYMBOL
statements.
A result of moving the fc_exch_seq_send, fc_seq_els_rsp_send, fc_exch_alloc
and fc_seq_start_next prototypes out of libfc.h is that they were no longer
being imported into fc_exch.c when libfc.h was included. This caused errors
where routines in fc_exch.c were looking for undefined symbols. To fix this
this patch reorganizes fc_seq_alloc, fc_seq_start_next and
fc_seq_start_next_locked. This move also made it so that
fc_seq_start_next_locked did not need to be prototyped at the top of
fc_exch.c.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This patch modifies scsi_host_template->change_queue_depth so that
it takes an argument indicating why it is being called. This will be
used so that if a LLD needs to do some extra processing when
handling queue fulls or later ramp ups, it can do so.
This is a simple port of the drivers setting a change_queue_depth
callback. In the patch I just have these LLDs adjust the queue depth
if the user was requesting it.
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
[Vasu.Dev: v2
Also converted pmcraid_change_queue_depth and then verified
all modules compile using "make allmodconfig" for any new build
warnings on X86_64.
Updated original description after combing two original
patches from Mike to make this patch git bisectable.]
Signed-off-by: Vasu Dev <vasu.dev@intel.com>
[jejb: fixed up 53c700]
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Timer crashes were caused by freeing a struct fc_rport_priv
with a timer pending, causing the timer facility list to be
corrupted. This was during FC uplink flap tests with a lot
of targets.
After discovery, we were doing an PLOGI on an rdata that was
in DELETE state but not yet removed from the lookup list.
This moved the rdata from DELETE state to PLOGI state.
If the PLOGI exchange allocation failed and needed to be
retried, the timer scheduling could race with the free
being done by fc_rport_work().
When fc_rport_login() is called on a rport in DELETE state,
move it to a new state RESTART. In fc_rport_work, when
handling a LOGO, STOPPED or FAILED event, look for restart
state. In the RESTART case, don't take the rdata off the
list and after the transport remote port is deleted and
exchanges are reset, re-login to the remote port.
Note that the new RESTART state also corrects a problem we
had when re-discovering a port that had moved to DELETE state.
In that case, a new rdata was created, but the old rdata
would do an exchange manager reset affecting the FC_ID
for both the new rdata and old rdata. With the new state,
the new port isn't logged into until after any old exchanges
are reset.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Reported-by: Alex Lyakas <alexl@mellanox.co.il>
Signed-off-by: Vasu Dev <vasu.dev@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When rport_login is called on an rport that is already thought
to be logged in, use ADISC. If that fails, redo PLOGI.
This is less disruptive after fabric changes that don't affect
the state of the target.
Implement the sending of ADISC via fc_els_fill.
Add ADISC state to the rport state machine. This is entered from READY
and returns to READY after successful completion. If it fails, the rport
is either logged off and deleted or re-does PLOGI.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Improve lport and rport debug messages to indicate whether
the response is LS_ACC, LS_RJT, closed, or timeout.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This moves the remote port lookup for incoming ELS requests into
fc_rport.c, in preparation for handing PLOGI and LOGO from
unknown rports.
This changes the arg to rport_recv_req from an rdata to an lport.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Currently these values are initialized by the callers. This was exposed
by a later patch that adds PLOGI request support. The patch failed to
initialize the new remote port's roles and it caused problems. This patch
has the rport_create routine initialize the identifiers and then the
callers can override them with real values.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When receiving an RSCN, do not log off all rports. This is
extremely disruptive. If, after the GPN_FT response, some
rports haven't been listed, delete them.
Add field disc_id to structs fc_rport_priv and fc_disc.
disc_id is an arbitrary serial number used to identify the
rports found by the latest discovery. This eliminates the need
to go through the rport list when restarting discovery.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Delete unused disc->delay element.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
There was no need to have the discovery status stored in struct fc_disc.
Change fc_disc_done() to take the discovery status as an argument
and just pass it on to the discovery callback.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Don't create a "dummy" remote port to go with fc_rport_priv.
Make the rport truly optional by allocating fc_rport_priv separately
and not requiring a dummy rport to be there if we haven't yet done
fc_remote_port_add().
The fc_rport_libfc_priv remains as a structure attached to the
rport for I/O purposes.
Be sure to hold references on rdata when the lock is dropped in
fc_rport_work().
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Remote ports will become READY more than once after
ADISC is implemented in a later patch.
The event callback that has been called "CREATED" will mean "READY".
Rename it now in preparation for those changes.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Allow a struct fc_rport_priv to have no fc_rport associated with it.
This sets up to remove the need for "rogue" rports.
Add a few fields to fc_rport_priv that are needed before the fc_rport
is created. These are the ids, maxframe_size, classes, and rport pointer.
Remove the macro PRIV_TO_RPORT(). Just use rdata->rport where appropriate.
To take the place of the get_device()/put_device ops that were used to
hold both the rport and rdata, add a reference count to rdata structures
using kref. When kref_get decrements the refcount to zero, a new template
function releasing the rdata should be called. This will take care of
freeing the rdata and releasing the hold on the rport (for now). After
subsequent patches make the rport truly optional, this release function
will simply free the rdata.
Remove the simple inline function fc_rport_set_name(), which becomes
semanticly ambiguous otherwise. The caller will set the port_name and
node_name in the rdata->Ids, which will later be copied to the rport
when it its created.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
tt.elsct_send is used by both FCP and by the rport state machine.
After further patches, these two modules will use different
structures for the remote port.
So, change elsct_send to use the FC_ID instead of the fc_rport_priv
as its argument. It currently only uses the FC_ID anyway.
For CT requests the destination FC_ID is still implicitly 0xfffffc.
After further patches the did arg on CT requests will be used to
specify the FC_ID being inquired about for GPN_ID or other queries.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>