Some regulators have different settling times for voltage increases and
decreases. Add DT properties to define separate settling times for up-
and downward voltage changes.
Signed-off-by: Matthias Kaehlcke <mka@chromium.org>
Acked-by: Laxman Dewangan <ldewangan@nvidia.com>
Acked-by: Rob Herring <robh@kernel.org>
Signed-off-by: Mark Brown <broonie@kernel.org>
Some regulators (some PWM regulators) have the voltage transition
exponentially. On such cases, the settling time for voltage change
is treated as constant time.
Add DT property for providing the settling time for any level of
voltage change for non-linear voltage change.
signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Acked-by: Rob Herring <robh@kernel.org>
Signed-off-by: Mark Brown <broonie@kernel.org>
Add common DT property for regulator node to support of
active discharge enable/disable configuration of regulator.
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
Introduce "regulator-allow-set-load" property to make it possible to
flag in the board configuration that a regulator is allowed to have the
load requirements changed.
Signed-off-by: Bjorn Andersson <bjorn.andersson@sonymobile.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
Some regulators can automatically shut down when they detect an
over current event. Add an op (set_over_current_protection) and a
DT property + constraint to support this capability.
Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>
Signed-off-by: Mark Brown <broonie@kernel.org>
Some regulators can limit their input current (typically annotated
as ilim). Add an op (set_input_current_limit) and a DT property +
constraint to support this.
Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>
Signed-off-by: Mark Brown <broonie@kernel.org>
Some regulators support a "soft start" feature where the voltage
ramps up slowly when the regulator is enabled. Add an op
(set_soft_start) and a DT property + constraint to support this.
Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>
Signed-off-by: Mark Brown <broonie@kernel.org>
Some regulators need to be configured to pull down a resistor
when the regulator is disabled. Add an op (set_pull_down) and a
DT property + constraint to support this.
Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>
Signed-off-by: Mark Brown <broonie@kernel.org>
Some regulators have a fixed load that isn't captured by
consumers that the kernel knows about. Add a constraint to
support this.
Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>
Signed-off-by: Mark Brown <broonie@kernel.org>
Some regulators can run on different operating modes (opmodes). This
allows systems to choose the most efficient opmode for each regulator.
This patch builds on top of (291d761 regulator: Document binding for
regulator suspend state for PM state) adding a regulator-initial-mode
DT property to configure at startup the operating mode for regulators
that support changing its mode during normal operation and a property
regulator-mode to be used in the regulator-state-[mem/disk] nodes for
regulators that supports changing its operating mode when the system
enters in a suspend state.
The set of possible modes that a regulator can operate depends on the
hardware capabilities so a list of generic operating modes can't be
provided. Instead, each hardware binding should define the list of
valid operating modes for the regulators found on that device.
Signed-off-by: Javier Martinez Canillas <javier.martinez@collabora.co.uk>
Signed-off-by: Mark Brown <broonie@kernel.org>
This patch builds upon (291d761 regulator: Document binding for
regulator suspend state for PM state) to allow setting the uV in
addition to the state at suspend time.
Signed-off-by: Doug Anderson <dianders@chromium.org>
Reviewed-by: Javier Martinez Canillas <javier.martinez@collabora.co.uk>
Reviewed-by: Chris Zhong <zyw@rock-chips.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
This patch add regulator suspend state to constraint in dt file. The regulation_
constraints structure already has regulator suspend state field as following.
The regulator suspend state control the state of regulator according to
PM (Power Management) state.
- struct regulator_state state_disk
- struct regulator_state state_mem
Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Acked-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
The turn-on time of the regulator depends on the regulator device's
electrical characteristics. Sometimes regulator turn-on time also
depends on the capacitive load on the given platform and it can be
more than the datasheet value.
The driver provides the enable-time as per datasheet.
Add support for configure the enable ramp time through regulator
constraints so that regulator core can take this value for enable
time for that regulator.
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Acked-by: Stephen Warren <swarren@nvidia.com>
Signed-off-by: Mark Brown <broonie@linaro.org>
Some hardwares support disabling ramp delay, so adding ramp_disable flag to
constraints. It will be used to figure out whether ramp_delay in constraints
is explicitly set to zero or its unintialized (zero by default).
And we don't need to call set_voltage_time_sel() for regulators for whom ramp
delay is disabled in constraints.
Signed-off-by: Yadwinder Singh Brar <yadi.brar@samsung.com>
Signed-off-by: Mark Brown <broonie@linaro.org>
Added a property to indicate if the regulator supports bypass mode.
Also modified of_get_regulation_constraints() to check for that
property and set appropriate constraints.
Signed-off-by: Kishon Vijay Abraham I <kishon@ti.com>
Signed-off-by: Mark Brown <broonie@linaro.org>
When the bindings for the TPS6586x regulator were being proposed, I
asserted that DT node naming rules for bus child nodes should also be
applied to nodes inside the TPS6586x regulator node itself. In other
words, that each node providing regulator init data should be named
after the type of object it represented ("regulator") and hence that
some other property was required to indicate which regulator the node
described ("regulator-compatible"). In turn this led to multiple nodes
having the same name, thus requiring node names to use a unit address
to make them unique, thus requiring reg properties within the nodes and
However, subsequent discussion indicates that the rules I was asserting
only applies to standardized bus nodes, and within a device's own node,
the binding can basically do anything sane that it wants.
Hence, this change deprecates the register-compatible property, and
instead uses node names to replace this functionality. This greatly
simplifies the device tree content, making them smaller and more legible.
The code is changed such that old device trees continue to work.
Signed-off-by: Stephen Warren <swarren@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Add the policy for regulator DT such that if device have multiple
regulator and its binding contains a child node that describes each
regulator then each regulator child node must have the property
"regulator-compatible" which matches with regulator name of their
hardware counterparts.
Modify the DT documentation of regulator devices to reflect this
policy.
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Acked-by: Stephen Warren <swarren@wwwdotorg.org>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This change makes it possible to set ramp_delay with 0.xxx mV/uS without
truncation issue.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
For some hardwares ramp_delay for BUCKs is a configurable parameter which can
be configured through DT or board file.This patch adds ramp_delay to regulator
constraints and allow user to configure it for regulators which supports this
feature, through DT or board file. It will provide two ways of setting the
ramp_delay for a regulator:
First, by setting it as constraints in board file(for configurable
regulators) and set_machine_constraints() will take care of setting it on
hardware by calling(the provided) .set_ramp_delay() operation(callback).
Second, by setting it as data in regulator_desc(as fixed/default
ramp_delay rate) for a regulator in driver.
regulator_set_voltage_time_sel() will give preference to
constraints->ramp_delay while reading ramp_delay rate for regulator. Similarly
users should also take care accordingly while refering ramp_delay rate(in case
of implementing their private .set_voltage_time_sel() callbacks for different
regulators).
[Rewrote subject for 80 columns -- broonie]
Signed-off-by: Yadwinder Singh Brar <yadi.brar@samsung.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Device tree compiler does not recognize '-' in label name. Instead,
'_' works fine.
Signed-off-by: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The helper routine is meant to be used by the regulator drivers
to extract the regulator_init_data structure from the data
that is passed from device tree.
'consumer_supplies' which is part of regulator_init_data is not extracted
as the regulator consumer mappings are passed through DT differently,
implemented in subsequent patches.
Similarly the regulator<-->parent/supply mapping is handled in
subsequent patches.
Also add documentation for regulator bindings to be used to pass
regulator_init_data struct information from device tree.
Some of the regulator properties which are linux and board specific,
are left out since its not clear if they can
be in someway embedded into the kernel or passed in from DT.
They will be revisited later.
Signed-off-by: Rajendra Nayak <rnayak@ti.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>