structure field directly, access the sensor device instead the
thermal zone's device for trace, relocate the traces in
drivers/thermal (Daniel Lezcano)
- Use the generic trip point for the i.MX and remove the get_trip_temp
ops (Daniel Lezcano)
- Use the devm_platform_ioremap_resource() in the Hisilicon driver
(Yang Li)
- Remove R-Car H3 ES1.* handling as public has only access to the ES2
version and the upstream support for the ES1 has been shutdown (Wolfram Sang)
- Add a delay after initializing the bank in order to let the time to
the hardware to initialze itself before reading the temperature
(Amjad Ouled-Ameur)
- Add MT8365 support (Amjad Ouled-Ameur)
-----BEGIN PGP SIGNATURE-----
iQEzBAABCAAdFiEEGn3N4YVz0WNVyHskqDIjiipP6E8FAmQof0cACgkQqDIjiipP
6E/tXQgArKKlM52mo3pg880JsiWOWGrS7pJN0x9MR0nqUm83sLTDf21fPoYmn+EJ
wrzClIX1iHCDVCWCVxao7OIT1mxez9L2NAHseXDSDQJcZ0fflTE8wZ8xeLr6q5GN
/ifHfCqiC98yejPcKIf2TqdGgqpCzyQ++sZoc3H6/jwysSkFlBc+YgKx+XasQR6k
5swQ3E81zx0ouB+t1GDieXB6YRsjZzR2KQbbExoHexPue1DTIuuumz8M1Fgz4a4b
gXRHbrGp3vmLORIAOZiVDyjzC7jwy7oN552g16yZLGDUdLaJ03gRRx7fvNzDUEMW
mBzxak4WnNWEatCh691X6W5MdPO/uQ==
=naJV
-----END PGP SIGNATURE-----
Merge tag 'thermal-v6.4-rc1-1' of ssh://gitolite.kernel.org/pub/scm/linux/kernel/git/thermal/linux
Pull thermal control material for 6.4-rc1 from Daniel Lezcano:
"- Add more thermal zone device encapsulation: prevent setting
structure field directly, access the sensor device instead the
thermal zone's device for trace, relocate the traces in
drivers/thermal (Daniel Lezcano)
- Use the generic trip point for the i.MX and remove the get_trip_temp
ops (Daniel Lezcano)
- Use the devm_platform_ioremap_resource() in the Hisilicon driver
(Yang Li)
- Remove R-Car H3 ES1.* handling as public has only access to the ES2
version and the upstream support for the ES1 has been shutdown (Wolfram
Sang)
- Add a delay after initializing the bank in order to let the time to
the hardware to initialze itself before reading the temperature
(Amjad Ouled-Ameur)
- Add MT8365 support (Amjad Ouled-Ameur)"
* tag 'thermal-v6.4-rc1-1' of ssh://gitolite.kernel.org/pub/scm/linux/kernel/git/thermal/linux:
thermal/drivers/ti: Use fixed update interval
thermal/drivers/stm: Don't set no_hwmon to false
thermal/drivers/db8500: Use driver dev instead of tz->device
thermal/core: Relocate the traces definition in thermal directory
thermal/drivers/hisi: Use devm_platform_ioremap_resource()
thermal/drivers/imx: Use the thermal framework for the trip point
thermal/drivers/imx: Remove get_trip_temp ops
thermal/drivers/rcar_gen3_thermal: Remove R-Car H3 ES1.* handling
thermal/drivers/mediatek: Add delay after thermal banks initialization
thermal/drivers/mediatek: Add support for MT8365 SoC
thermal/drivers/mediatek: Control buffer enablement tweaks
dt-bindings: thermal: mediatek: Add binding documentation for MT8365 SoC
The traces are exported but only local to the thermal core code. On
the other side, the traces take the thermal zone device structure as
argument, thus they have to rely on the exported thermal.h header
file. As we want to move the structure to the private thermal core
header, first we have to relocate those traces to the same place as
many drivers do.
Cc: Steven Rostedt <rostedt@goodmis.org>
Suggested-by: Steven Rostedt <rostedt@goodmis.org>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Reviewed-by: Steven Rostedt (Google) <rostedt@goodmis.org>
Link: https://lore.kernel.org/r/20230307133735.90772-2-daniel.lezcano@linaro.org
It is preferred to use typed property access functions (i.e.
of_property_read_<type> functions) rather than low-level
of_get_property/of_find_property functions for reading properties. As
part of this, convert of_get_property/of_find_property calls to the
recently added of_property_present() helper when we just want to test
for presence of a property and nothing more.
Signed-off-by: Rob Herring <robh@kernel.org>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Merge thermal control driver changes for 6.1-rc1:
- Use module_pci_driver() macro in the int340x processor_thermal
driver (Shang XiaoJing).
- Use get_cpu() instead of smp_processor_id() in the intel_powerclamp
thermal driver to prevent it from crashing and remove unused
accounting for IRQ wakes from it (Srinivas Pandruvada).
- Consolidate priv->data_vault checks in int340x_thermal (Rafael
Wysocki).
- Check the policy first in cpufreq_cooling_register() (Xuewen Yan).
- Drop redundant error message from da9062-thermal (zhaoxiao).
- Drop of_match_ptr() from thermal_mmio (Jean Delvare).
* thermal-intel:
thermal: int340x: processor_thermal: Use module_pci_driver() macro
thermal: intel_powerclamp: Remove accounting for IRQ wakes
thermal: intel_powerclamp: Use get_cpu() instead of smp_processor_id() to avoid crash
thermal: int340x_thermal: Consolidate priv->data_vault checks
* thermal-drivers:
thermal: cpufreq_cooling: Check the policy first in cpufreq_cooling_register()
thermal: da9062-thermal: Drop redundant error message
thermal/drivers/thermal_mmio: Drop of_match_ptr()
Since the policy needs to be accessed first when obtaining cpu devices,
first check whether the policy is legal before this.
Fixes: 5130802ddb ("thermal: cpu_cooling: Switch to QoS requests for freq limits")
Signed-off-by: Xuewen Yan <xuewen.yan@unisoc.com>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Drop duplicate words from two kerneldoc comments in the thermal
subsystem.
Signed-off-by: Jilin Yuan <yuanjilin@cdjrlc.com>
[ rjw: Subject edits and changelog rewrite ]
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
- Consolidate the thermal core code by beginning to move the thermal
trip structure from the thermal OF code as a generic structure to be
used by the different sensors when registering a thermal zone
(Daniel Lezcano).
- Make per cpufreq / devfreq cooling device ops instead of using a
global variable, fix comments and rework the trace information
(Lukasz Luba).
- Add the include/dt-bindings/thermal.h under the area covered by the
thermal maintainer in the MAINTAINERS file (Lukas Bulwahn).
- Improve the error output by giving the sensor identification when a
thermal zone failed to initialize, the DT bindings by changing the
positive logic and adding the r8a779f0 support on the rcar3 (Wolfram
Sang).
- Convert the QCom tsens DT binding to the dtsformat format (Krzysztof
Kozlowski).
- Remove the pointless get_trend() function in the QCom, Ux500 and
tegra thermal drivers, along with the unused DROP_FULL and
RAISE_FULL trends definitions. Simplify the code by using clamp()
macros (Daniel Lezcano).
- Fix ref_table memory leak at probe time on the k3_j72xx bandgap
(Bryan Brattlof).
- Fix array underflow in prep_lookup_table (Dan Carpenter).
- Add static annotation to the k3_j72xx_bandgap_j7* data structure
(Jin Xiaoyun).
- Fix typos in comments detected on sun8i by Coccinelle (Julia
Lawall).
- Fix typos in comments on rzg2l (Biju Das).
- Remove as unnecessary call to dev_err() as the error is already
printed by the failing function on u8500 (Yang Li).
- Register the thermal zones as hwmon sensors for the Qcom thermal
sensors (Dmitry Baryshkov).
- Fix 'tmon' tool compilation issue by adding phtread.h include
(Markus Mayer).
- Fix typo in the comments for the 'tmon' tool (Slark Xiao).
- Make the thermal core use ida_alloc()/free() directly instead of
ida_simple_get()/ida_simple_remove() that have been deprecated
(keliu).
- Drop ACPI_FADT_LOW_POWER_S0 check from the Intel PCH thermal control
driver (Rafael Wysocki).
-----BEGIN PGP SIGNATURE-----
iQJGBAABCAAwFiEE4fcc61cGeeHD/fCwgsRv/nhiVHEFAmLoK5ASHHJqd0Byand5
c29ja2kubmV0AAoJEILEb/54YlRxa0cQAJsl3wDxkDbvfEENZ1VSdfeH3qXbUSSE
EEo0j4X85JE1F1NwT8R2tb4D/YMJDT3p6I55twrVLvxNUdTnx7ybRfXem24uXkK5
xOybfsuYsSWXxaEfI4260GBzY6ijTR7uWYyDLPN3vvbW3FdMj+nni0D9uTySw7UL
ecIe1ISn3nxbbp0FxYh+n88+718HWKo07BaTE4TyKeUgQHw+v7HHtCZq7Rdoogm8
cp6tTkJ8ymrHoEvAWBIcO58zCx7LkSFeU69oMm4CUzVjxWdFfREb079F5cZ92GXr
ex70r/gKfFAd5GAAdL0WjeS4RwHKta49WKqAMA7w41nIgDj0IA2gJRowfJvKDkF+
JgcQ7OrJ5eo5jCr4pbycgQ9Lh23zBQe/3LH+yV71KlKiLf6/Tl5rhELfBNbZmraZ
HOvD5dAxBLySmANN2VX7DJgtbTcinneL9BDVo6dBTdYaWC4jQxXYm73n66nkZdS7
BDJ0N2P0uZ7NGLawXwrrsMi8xbIApMw4W/o8SN9R4FF1LqIroDg60kLJ9zO+6IhI
xF8ZtcMdyPVa71fSZNwD0+mz2sF6XnTucf88CjxzVdAxbvNVPQEvKufThWTreyuU
pjBPtf1YFOFz9CusBYAplOIu96RqUgL1t1aqqwsCqXoUu4Lgh/pyksIDeam1l0EP
Q5WBUB9bK8q8
=wj9M
-----END PGP SIGNATURE-----
Merge tag 'thermal-5.20-rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/rafael/linux-pm
Pull thermal control updates from Rafael Wysocki:
"These start a rework of the handling of trip points in the thermal
core, improve the cpufreq/devfreq cooling device handling, update some
thermal control drivers and the tmon utility and clean up code.
Specifics:
- Consolidate the thermal core code by beginning to move the thermal
trip structure from the thermal OF code as a generic structure to
be used by the different sensors when registering a thermal zone
(Daniel Lezcano).
- Make per cpufreq / devfreq cooling device ops instead of using a
global variable, fix comments and rework the trace information
(Lukasz Luba).
- Add the include/dt-bindings/thermal.h under the area covered by the
thermal maintainer in the MAINTAINERS file (Lukas Bulwahn).
- Improve the error output by giving the sensor identification when a
thermal zone failed to initialize, the DT bindings by changing the
positive logic and adding the r8a779f0 support on the rcar3
(Wolfram Sang).
- Convert the QCom tsens DT binding to the dtsformat format
(Krzysztof Kozlowski).
- Remove the pointless get_trend() function in the QCom, Ux500 and
tegra thermal drivers, along with the unused DROP_FULL and
RAISE_FULL trends definitions. Simplify the code by using clamp()
macros (Daniel Lezcano).
- Fix ref_table memory leak at probe time on the k3_j72xx bandgap
(Bryan Brattlof).
- Fix array underflow in prep_lookup_table (Dan Carpenter).
- Add static annotation to the k3_j72xx_bandgap_j7* data structure
(Jin Xiaoyun).
- Fix typos in comments detected on sun8i by Coccinelle (Julia
Lawall).
- Fix typos in comments on rzg2l (Biju Das).
- Remove as unnecessary call to dev_err() as the error is already
printed by the failing function on u8500 (Yang Li).
- Register the thermal zones as hwmon sensors for the Qcom thermal
sensors (Dmitry Baryshkov).
- Fix 'tmon' tool compilation issue by adding phtread.h include
(Markus Mayer).
- Fix typo in the comments for the 'tmon' tool (Slark Xiao).
- Make the thermal core use ida_alloc()/free() directly instead of
ida_simple_get()/ida_simple_remove() that have been deprecated
(keliu).
- Drop ACPI_FADT_LOW_POWER_S0 check from the Intel PCH thermal
control driver (Rafael Wysocki)"
* tag 'thermal-5.20-rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/rafael/linux-pm: (39 commits)
thermal/of: Initialize trip points separately
thermal/of: Use thermal trips stored in the thermal zone
thermal/core: Add thermal_trip in thermal_zone
thermal/core: Rename 'trips' to 'num_trips'
thermal/core: Move thermal_set_delay_jiffies to static
thermal/core: Remove unneeded EXPORT_SYMBOLS
thermal/of: Move thermal_trip structure to thermal.h
thermal/of: Remove the device node pointer for thermal_trip
thermal/of: Replace device node match with device node search
thermal/core: Remove duplicate information when an error occurs
thermal/core: Avoid calling ->get_trip_temp() unnecessarily
thermal/tools/tmon: Fix typo 'the the' in comment
thermal/tools/tmon: Include pthread and time headers in tmon.h
thermal/ti-soc-thermal: Fix comment typo
thermal/drivers/qcom/spmi-adc-tm5: Register thermal zones as hwmon sensors
thermal/drivers/qcom/temp-alarm: Register thermal zones as hwmon sensors
thermal/drivers/u8500: Remove unnecessary print function dev_err()
thermal/drivers/rzg2l: Fix comments
thermal/drivers/sun8i: Fix typo in comment
thermal/drivers/k3_j72xx_bandgap: Make k3_j72xx_bandgap_j721e_data and k3_j72xx_bandgap_j7200_data static
...
- Make cpufreq_show_cpus() more straightforward (Viresh Kumar).
- Drop unnecessary CPU hotplug locking from store() used by cpufreq
sysfs attributes (Viresh Kumar).
- Make the ACPI cpufreq driver support the boost control interface on
Zhaoxin/Centaur processors (Tony W Wang-oc).
- Print a warning message on attempts to free an active cpufreq policy
which should never happen (Viresh Kumar).
- Fix grammar in the Kconfig help text for the loongson2 cpufreq
driver (Randy Dunlap).
- Use cpumask_var_t for an on-stack CPU mask in the ondemand cpufreq
governor (Zhao Liu).
- Add trace points for guest_halt_poll_ns grow/shrink to the haltpoll
cpuidle driver (Eiichi Tsukata).
- Modify intel_idle to treat C1 and C1E as independent idle states on
Sapphire Rapids (Artem Bityutskiy).
- Extend support for wakeirq to callback wrappers used during system
suspend and resume (Ulf Hansson).
- Defer waiting for device probe before loading a hibernation image
till the first actual device access to avoid possible deadlocks
reported by syzbot (Tetsuo Handa).
- Unify device_init_wakeup() for PM_SLEEP and !PM_SLEEP (Bjorn
Helgaas).
- Add Raptor Lake-P to the list of processors supported by the Intel
RAPL driver (George D Sworo).
- Add Alder Lake-N and Raptor Lake-P to the list of processors for
which Power Limit4 is supported in the Intel RAPL driver (Sumeet
Pawnikar).
- Make pm_genpd_remove() check genpd_debugfs_dir against NULL before
attempting to remove it (Hsin-Yi Wang).
- Change the Energy Model code to represent power in micro-Watts and
adjust its users accordingly (Lukasz Luba).
- Add new devfreq driver for Mediatek CCI (Cache Coherent
Interconnect) (Johnson Wang).
- Convert the Samsung Exynos SoC Bus bindings to DT schema of
exynos-bus.c (Krzysztof Kozlowski).
- Address kernel-doc warnings by adding the description for unused
fucntion parameters in devfreq core (Mauro Carvalho Chehab).
- Use NULL to pass a null pointer rather than zero according to the
function propotype in imx-bus.c (Colin Ian King).
- Print error message instead of error interger value in
tegra30-devfreq.c (Dmitry Osipenko).
- Add checks to prevent setting negative frequency QoS limits for
CPUs (Shivnandan Kumar).
- Update the pm-graph suite of utilities to the latest revision 5.9
including multiple improvements (Todd Brandt).
- Drop pme_interrupt reference from the PCI power management
documentation (Mario Limonciello).
-----BEGIN PGP SIGNATURE-----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=XeLV
-----END PGP SIGNATURE-----
Merge tag 'pm-5.20-rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/rafael/linux-pm
Pull power management updates from Rafael Wysocki:
"These are mostly minor improvements all over including new CPU IDs for
the Intel RAPL driver, an Energy Model rework to use micro-Watt as the
power unit, cpufreq fixes and cleanus, cpuidle updates, devfreq
updates, documentation cleanups and a new version of the pm-graph
suite of utilities.
Specifics:
- Make cpufreq_show_cpus() more straightforward (Viresh Kumar).
- Drop unnecessary CPU hotplug locking from store() used by cpufreq
sysfs attributes (Viresh Kumar).
- Make the ACPI cpufreq driver support the boost control interface on
Zhaoxin/Centaur processors (Tony W Wang-oc).
- Print a warning message on attempts to free an active cpufreq
policy which should never happen (Viresh Kumar).
- Fix grammar in the Kconfig help text for the loongson2 cpufreq
driver (Randy Dunlap).
- Use cpumask_var_t for an on-stack CPU mask in the ondemand cpufreq
governor (Zhao Liu).
- Add trace points for guest_halt_poll_ns grow/shrink to the haltpoll
cpuidle driver (Eiichi Tsukata).
- Modify intel_idle to treat C1 and C1E as independent idle states on
Sapphire Rapids (Artem Bityutskiy).
- Extend support for wakeirq to callback wrappers used during system
suspend and resume (Ulf Hansson).
- Defer waiting for device probe before loading a hibernation image
till the first actual device access to avoid possible deadlocks
reported by syzbot (Tetsuo Handa).
- Unify device_init_wakeup() for PM_SLEEP and !PM_SLEEP (Bjorn
Helgaas).
- Add Raptor Lake-P to the list of processors supported by the Intel
RAPL driver (George D Sworo).
- Add Alder Lake-N and Raptor Lake-P to the list of processors for
which Power Limit4 is supported in the Intel RAPL driver (Sumeet
Pawnikar).
- Make pm_genpd_remove() check genpd_debugfs_dir against NULL before
attempting to remove it (Hsin-Yi Wang).
- Change the Energy Model code to represent power in micro-Watts and
adjust its users accordingly (Lukasz Luba).
- Add new devfreq driver for Mediatek CCI (Cache Coherent
Interconnect) (Johnson Wang).
- Convert the Samsung Exynos SoC Bus bindings to DT schema of
exynos-bus.c (Krzysztof Kozlowski).
- Address kernel-doc warnings by adding the description for unused
function parameters in devfreq core (Mauro Carvalho Chehab).
- Use NULL to pass a null pointer rather than zero according to the
function propotype in imx-bus.c (Colin Ian King).
- Print error message instead of error interger value in
tegra30-devfreq.c (Dmitry Osipenko).
- Add checks to prevent setting negative frequency QoS limits for
CPUs (Shivnandan Kumar).
- Update the pm-graph suite of utilities to the latest revision 5.9
including multiple improvements (Todd Brandt).
- Drop pme_interrupt reference from the PCI power management
documentation (Mario Limonciello)"
* tag 'pm-5.20-rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/rafael/linux-pm: (27 commits)
powercap: RAPL: Add Power Limit4 support for Alder Lake-N and Raptor Lake-P
PM: QoS: Add check to make sure CPU freq is non-negative
PM: hibernate: defer device probing when resuming from hibernation
intel_idle: make SPR C1 and C1E be independent
cpufreq: ondemand: Use cpumask_var_t for on-stack cpu mask
cpufreq: loongson2: fix Kconfig "its" grammar
pm-graph v5.9
cpufreq: Warn users while freeing active policy
cpufreq: scmi: Support the power scale in micro-Watts in SCMI v3.1
firmware: arm_scmi: Get detailed power scale from perf
Documentation: EM: Switch to micro-Watts scale
PM: EM: convert power field to micro-Watts precision and align drivers
PM / devfreq: tegra30: Add error message for devm_devfreq_add_device()
PM / devfreq: imx-bus: use NULL to pass a null pointer rather than zero
PM / devfreq: shut up kernel-doc warnings
dt-bindings: interconnect: samsung,exynos-bus: convert to dtschema
PM / devfreq: mediatek: Introduce MediaTek CCI devfreq driver
dt-bindings: interconnect: Add MediaTek CCI dt-bindings
PM: domains: Ensure genpd_debugfs_dir exists before remove
PM: runtime: Extend support for wakeirq for force_suspend|resume
...
The code has moved and left some comments stale. Update them where
there is a need.
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Link: https://lore.kernel.org/r/20220613124327.30766-4-lukasz.luba@arm.com
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Simplify the thermal_power_cpu_get_power trace event by removing
complicated cpumask and variable length array. Now the tools parsing trace
output don't have to hassle to get this power data. The simplified format
version uses 'policy->cpu'. Remove also the 'load' information completely
since there is very little value of it in this trace event. To get the
CPUs' load (or utilization) there are other dedicated trace hooks in the
kernel. This patch also simplifies and speeds-up the main cooling code
when that trace event is enabled.
Rename the trace event to avoid confusion of tools which parse the trace
file.
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Link: https://lore.kernel.org/r/20220613124327.30766-3-lukasz.luba@arm.com
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
It is very unlikely that one CPU cluster would have the EM and some other
won't have it (because EM registration failed or DT lacks needed entry).
Although, we should avoid modifying global variable with callbacks anyway.
Redesign this and add safety for such situation.
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Link: https://lore.kernel.org/r/20220613124327.30766-2-lukasz.luba@arm.com
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
The milli-Watts precision causes rounding errors while calculating
efficiency cost for each OPP. This is especially visible in the 'simple'
Energy Model (EM), where the power for each OPP is provided from OPP
framework. This can cause some OPPs to be marked inefficient, while
using micro-Watts precision that might not happen.
Update all EM users which access 'power' field and assume the value is
in milli-Watts.
Solve also an issue with potential overflow in calculation of energy
estimation on 32bit machine. It's needed now since the power value
(thus the 'cost' as well) are higher.
Example calculation which shows the rounding error and impact:
power = 'dyn-power-coeff' * volt_mV * volt_mV * freq_MHz
power_a_uW = (100 * 600mW * 600mW * 500MHz) / 10^6 = 18000
power_a_mW = (100 * 600mW * 600mW * 500MHz) / 10^9 = 18
power_b_uW = (100 * 605mW * 605mW * 600MHz) / 10^6 = 21961
power_b_mW = (100 * 605mW * 605mW * 600MHz) / 10^9 = 21
max_freq = 2000MHz
cost_a_mW = 18 * 2000MHz/500MHz = 72
cost_a_uW = 18000 * 2000MHz/500MHz = 72000
cost_b_mW = 21 * 2000MHz/600MHz = 70 // <- artificially better
cost_b_uW = 21961 * 2000MHz/600MHz = 73203
The 'cost_b_mW' (which is based on old milli-Watts) is misleadingly
better that the 'cost_b_uW' (this patch uses micro-Watts) and such
would have impact on the 'inefficient OPPs' information in the Cpufreq
framework. This patch set removes the rounding issue.
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Acked-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
effective_cpu_util() already has a `int cpu' parameter which allows to
retrieve the CPU capacity scale factor (or maximum CPU capacity) inside
this function via an arch_scale_cpu_capacity(cpu).
A lot of code calling effective_cpu_util() (or the shim
sched_cpu_util()) needs the maximum CPU capacity, i.e. it will call
arch_scale_cpu_capacity() already.
But not having to pass it into effective_cpu_util() will make the EAS
wake-up code easier, especially when the maximum CPU capacity reduced
by the thermal pressure is passed through the EAS wake-up functions.
Due to the asymmetric CPU capacity support of arm/arm64 architectures,
arch_scale_cpu_capacity(int cpu) is a per-CPU variable read access via
per_cpu(cpu_scale, cpu) on such a system.
On all other architectures it is a a compile-time constant
(SCHED_CAPACITY_SCALE).
Signed-off-by: Dietmar Eggemann <dietmar.eggemann@arm.com>
Signed-off-by: Peter Zijlstra (Intel) <peterz@infradead.org>
Acked-by: Vincent Guittot <vincent.guittot@linaro.org>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Link: https://lkml.kernel.org/r/20220621090414.433602-4-vdonnefort@google.com
The Energy Model can now be artificial, which means the power values
are mathematically generated to leverage EAS while not expected to be on
an uniform scale with other devices providing power information. If this
EM type is in use, the thermal governor IPA should not be allowed to
operate, since the relation between cooling devices is not properly
defined. Thus, it might be possible that big GPU has lower power values
than a Little CPU. To mitigate a misbehaviour of the thermal control
algorithm, simply do not register the cooling device as IPA's power
actor.
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Ionela Voinescu <ionela.voinescu@arm.com>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Thermal pressure provides a new API, which allows to use CPU frequency
as an argument. That removes the need of local conversion to capacity.
Use this new function and remove old conversion code.
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
The thermal pressure signal gives information to the scheduler about
reduced CPU capacity due to thermal. It is based on a value stored in
a per-cpu 'thermal_pressure' variable. The online CPUs will get the
new value there, while the offline won't. Unfortunately, when the CPU
is back online, the value read from per-cpu variable might be wrong
(stale data). This might affect the scheduler decisions, since it
sees the CPU capacity differently than what is actually available.
Fix it by making sure that all online+offline CPUs would get the
proper value in their per-cpu variable when thermal framework sets
capping.
Fixes: f12e4f66ab ("thermal/cpu-cooling: Update thermal pressure in case of a maximum frequency capping")
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Peter Zijlstra (Intel) <peterz@infradead.org>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Link: https://lore.kernel.org/r/20210614191030.22241-1-lukasz.luba@arm.com
Slab OOB issue is scanned by KASAN in cpu_power_to_freq().
If power is limited below the power of OPP0 in EM table,
it will cause slab out-of-bound issue with negative array
index.
Return the lowest frequency if limited power cannot found
a suitable OPP in EM table to fix this issue.
Backtrace:
[<ffffffd02d2a37f0>] die+0x104/0x5ac
[<ffffffd02d2a5630>] bug_handler+0x64/0xd0
[<ffffffd02d288ce4>] brk_handler+0x160/0x258
[<ffffffd02d281e5c>] do_debug_exception+0x248/0x3f0
[<ffffffd02d284488>] el1_dbg+0x14/0xbc
[<ffffffd02d75d1d4>] __kasan_report+0x1dc/0x1e0
[<ffffffd02d75c2e0>] kasan_report+0x10/0x20
[<ffffffd02d75def8>] __asan_report_load8_noabort+0x18/0x28
[<ffffffd02e6fce5c>] cpufreq_power2state+0x180/0x43c
[<ffffffd02e6ead80>] power_actor_set_power+0x114/0x1d4
[<ffffffd02e6fac24>] allocate_power+0xaec/0xde0
[<ffffffd02e6f9f80>] power_allocator_throttle+0x3ec/0x5a4
[<ffffffd02e6ea888>] handle_thermal_trip+0x160/0x294
[<ffffffd02e6edd08>] thermal_zone_device_check+0xe4/0x154
[<ffffffd02d351cb4>] process_one_work+0x5e4/0xe28
[<ffffffd02d352f44>] worker_thread+0xa4c/0xfac
[<ffffffd02d360124>] kthread+0x33c/0x358
[<ffffffd02d289940>] ret_from_fork+0xc/0x18
Fixes: 371a3bc79c ("thermal/drivers/cpufreq_cooling: Fix wrong frequency converted from power")
Signed-off-by: brian-sy yang <brian-sy.yang@mediatek.com>
Signed-off-by: Michael Kao <michael.kao@mediatek.com>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Cc: stable@vger.kernel.org #v5.7
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20201229050831.19493-1-michael.kao@mediatek.com
There is a list with the purpose of grouping the cpufreq cooling
device together as described in the comments but actually it is
unused, the code evolved since 2012 and the list was no longer needed.
Delete the remaining unused list related code.
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Link: https://lore.kernel.org/r/20210314111333.16551-5-daniel.lezcano@linaro.org
Currently the naming of a cooling device is just a cooling technique
followed by a number. When there are multiple cooling devices using
the same technique, it is impossible to clearly identify the related
device as this one is just a number.
For instance:
thermal-cpufreq-0
thermal-cpufreq-1
etc ...
The 'thermal' prefix is redundant with the subsystem namespace. This
patch removes the 'thermal' prefix and changes the number by the device
name. So the naming above becomes:
cpufreq-cpu0
cpufreq-cpu4
etc ...
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Link: https://lore.kernel.org/r/20210314111333.16551-2-daniel.lezcano@linaro.org
thermal driver (Daniel Lezcano)
- Remove the notify ops as it is no longer used (Daniel Lezcano)
- Remove the 'forced passive' option and the unused bind/unbind
functions (Daniel Lezcano)
- Remove the THERMAL_TRIPS_NONE and the code cleanup around this
macro (Daniel Lezcano)
- Rework the delays to make them pre-computed instead of computing
them again and again at each polling interval (Daniel Lezcano)
- Remove the pointless 'thermal_zone_device_reset' function (Daniel
Lezcano)
- Use the critical and hot ops to prevent an unexpected system
shutdown on int340x (Kai-Heng Feng)
- Make the cooling device state private to the thermal subsystem
(Daniel Lezcano)
- Prevent to use not-power-aware actor devices with the power
allocator governor (Lukasz Luba)
- Remove 'zx' and 'tango' support along with the corresponding
platforms (Arnd Bergman)
- Fix several issues on the Omap thermal driver (Tony Lindgren)
- Add support for adc-tm5 PMIC thermal monitor for Qcom
platforms. Please note those changes rely on an immutable branch:
iio-thermal-5.11-rc1/ib-iio-thermal-5.11-rc1 from the iio tree
(Dmitry Baryshkov)
- Fix an initialization loop in the adc-tm5 (Colin Ian King)
- Fix a return error check in the cpufreq cooling device (Viresh Kumar)
-----BEGIN PGP SIGNATURE-----
iQEzBAABCAAdFiEEGn3N4YVz0WNVyHskqDIjiipP6E8FAmAvkKMACgkQqDIjiipP
6E9yFggAmXy8t2j1mRvn/KLU+teTGIoSFkZ8mBnY2Sgip97IRZRhCwAZbUKOW0eI
bvpAzBjacxdZHT7OxxvGzCOq/zlAh4UoStI8bMpzdUWPdkAj4ippArLYGvagLym8
WEQysWnrr8V1RCZbQuBNjyLwjf0fcXkzIBU1mbZXA8T8Y6Yn646TdtsrVT4Idg1j
MOg7PAHBcTSY/wOReZKJ5TB1yvo2tNOuGOqUVbrIAHlRkiNTVHirVUq6aZGtTTKp
7ukcu8EI/o7XKBdQ5d9MZaHdwkcyAIJj4jdjmjkUJpa8VYQFPjayNyN3I+Py9lH2
jtWVYHQxZbY166IZP2yeXFjPzd6elw==
=Jmz4
-----END PGP SIGNATURE-----
Merge tag 'thermal-v5.12-rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/thermal/linux
Pull thermal updates from Daniel Lezcano:
- Use the newly introduced 'hot' and 'critical' ops for the acpi
thermal driver (Daniel Lezcano)
- Remove the notify ops as it is no longer used (Daniel Lezcano)
- Remove the 'forced passive' option and the unused bind/unbind
functions (Daniel Lezcano)
- Remove the THERMAL_TRIPS_NONE and the code cleanup around this macro
(Daniel Lezcano)
- Rework the delays to make them pre-computed instead of computing them
again and again at each polling interval (Daniel Lezcano)
- Remove the pointless 'thermal_zone_device_reset' function (Daniel
Lezcano)
- Use the critical and hot ops to prevent an unexpected system shutdown
on int340x (Kai-Heng Feng)
- Make the cooling device state private to the thermal subsystem
(Daniel Lezcano)
- Prevent to use not-power-aware actor devices with the power allocator
governor (Lukasz Luba)
- Remove 'zx' and 'tango' support along with the corresponding
platforms (Arnd Bergman)
- Fix several issues on the Omap thermal driver (Tony Lindgren)
- Add support for adc-tm5 PMIC thermal monitor for Qcom platforms
(Dmitry Baryshkov)
- Fix an initialization loop in the adc-tm5 (Colin Ian King)
- Fix a return error check in the cpufreq cooling device (Viresh Kumar)
* tag 'thermal-v5.12-rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/thermal/linux: (26 commits)
thermal: cpufreq_cooling: freq_qos_update_request() returns < 0 on error
thermal: qcom: Fix comparison with uninitialized variable channels_available
thermal: qcom: add support for adc-tm5 PMIC thermal monitor
dt-bindings: thermal: qcom: add adc-thermal monitor bindings
thermal: ti-soc-thermal: Use non-inverted define for omap4
thermal: ti-soc-thermal: Simplify polling with iopoll
thermal: ti-soc-thermal: Fix stuck sensor with continuous mode for 4430
thermal: ti-soc-thermal: Skip pointless register access for dra7
thermal/drivers/zx: Remove zx driver
thermal/drivers/tango: Remove tango driver
thermal: power allocator: fail binding for non-power actor devices
thermal/core: Make cooling device state change private
thermal: intel: pch: Fix unexpected shutdown at critical temperature
thermal: int340x: Fix unexpected shutdown at critical temperature
thermal/core: Remove pointless thermal_zone_device_reset() function
thermal/core: Remove ms based delay fields
thermal/core: Use precomputed jiffies for the polling
thermal/core: Precompute the delays from msecs to jiffies
thermal/core: Remove unused macro THERMAL_TRIPS_NONE
thermal/core: Remove THERMAL_TRIPS_NONE test
...
freq_qos_update_request() returns 1 if the effective constraint value
has changed, 0 if the effective constraint value has not changed, or a
negative error code on failures.
The frequency constraints for CPUs can be set by different parts of the
kernel. If the maximum frequency constraint set by other parts of the
kernel are set at a lower value than the one corresponding to cooling
state 0, then we will never be able to cool down the system as
freq_qos_update_request() will keep on returning 0 and we will skip
updating cpufreq_state and thermal pressure.
Fix that by doing the updates even in the case where
freq_qos_update_request() returns 0, as we have effectively set the
constraint to a new value even if the consolidated value of the
actual constraint is unchanged because of external factors.
Cc: v5.7+ <stable@vger.kernel.org> # v5.7+
Reported-by: Thara Gopinath <thara.gopinath@linaro.org>
Fixes: f12e4f66ab ("thermal/cpu-cooling: Update thermal pressure in case of a maximum frequency capping")
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Reviewed-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Tested-by: Thara Gopinath<thara.gopinath@linaro.org>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/b2b7e84944937390256669df5a48ce5abba0c1ef.1613540713.git.viresh.kumar@linaro.org
Several parts of the kernel are already using the effective CPU
utilization (as seen by the scheduler) to get the current load on the
CPU, do the same here instead of depending on the idle time of the CPU,
which isn't that accurate comparatively.
This is also the right thing to do as it makes the cpufreq governor
(schedutil) align better with the cpufreq_cooling driver, as the power
requested by cpufreq_cooling governor will exactly match the next
frequency requested by the schedutil governor since they are both using
the same metric to calculate load.
This was tested on ARM Hikey6220 platform with hackbench, sysbench and
schbench. None of them showed any regression or significant
improvements. Schbench is the most important ones out of these as it
creates the scenario where the utilization numbers provide a better
estimate of the future.
Scenario 1: The CPUs were mostly idle in the previous polling window of
the IPA governor as the tasks were sleeping and here are the details
from traces (load is in %):
Old: thermal_power_cpu_get_power: cpus=00000000,000000ff freq=1200000 total_load=203 load={{0x35,0x1,0x0,0x31,0x0,0x0,0x64,0x0}} dynamic_power=1339
New: thermal_power_cpu_get_power: cpus=00000000,000000ff freq=1200000 total_load=600 load={{0x60,0x46,0x45,0x45,0x48,0x3b,0x61,0x44}} dynamic_power=3960
Here, the "Old" line gives the load and requested_power (dynamic_power
here) numbers calculated using the idle time based implementation, while
"New" is based on the CPU utilization from scheduler.
As can be clearly seen, the load and requested_power numbers are simply
incorrect in the idle time based approach and the numbers collected from
CPU's utilization are much closer to the reality.
Scenario 2: The CPUs were busy in the previous polling window of the IPA
governor:
Old: thermal_power_cpu_get_power: cpus=00000000,000000ff freq=1200000 total_load=800 load={{0x64,0x64,0x64,0x64,0x64,0x64,0x64,0x64}} dynamic_power=5280
New: thermal_power_cpu_get_power: cpus=00000000,000000ff freq=1200000 total_load=708 load={{0x4d,0x5c,0x5c,0x5b,0x5c,0x5c,0x51,0x5b}} dynamic_power=4672
As can be seen, the idle time based load is 100% for all the CPUs as it
took only the last window into account, but in reality the CPUs aren't
that loaded as shown by the utilization numbers.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Peter Zijlstra (Intel) <peterz@infradead.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Link: https://lkml.kernel.org/r/9c255c83d78d58451abc06848001faef94c87a12.1607400596.git.viresh.kumar@linaro.org
If state has not changed successfully and we updated cpufreq_state,
next time when the new state is equal to cpufreq_state (not changed
successfully last time), we will return directly and miss a
freq_qos_update_request() that should have been.
Fixes: 5130802ddb ("thermal: cpu_cooling: Switch to QoS requests for freq limits")
Cc: v5.4+ <stable@vger.kernel.org> # v5.4+
Signed-off-by: Zhuguangqing <zhuguangqing@xiaomi.com>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20201106092243.15574-1-zhuguangqing83@gmail.com
1. devfreq_cooling.c: The variable *tz is not used in
devfreq_cooling_get_requested_power(), devfreq_cooling_state2power()
and devfreq_cooling_power2state().
2. cpufreq_cooling.c: After 84fe2cab48, the variable *tz is not used
anymore in cpufreq_get_requested_power(), cpufreq_state2power() and
cpufreq_power2state().
Remove the variable *tz.
Signed-off-by: zhuguangqing <zhuguangqing@xiaomi.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20200914071101.13575-1-zhuguangqing83@gmail.com
* pm-em:
OPP: refactor dev_pm_opp_of_register_em() and update related drivers
Documentation: power: update Energy Model description
PM / EM: change name of em_pd_energy to em_cpu_energy
PM / EM: remove em_register_perf_domain
PM / EM: add support for other devices than CPUs in Energy Model
PM / EM: update callback structure and add device pointer
PM / EM: introduce em_dev_register_perf_domain function
PM / EM: change naming convention from 'capacity' to 'performance'
* pm-core:
mmc: jz4740: Use pm_ptr() macro
PM: Make *_DEV_PM_OPS macros use __maybe_unused
PM: core: introduce pm_ptr() macro
The function cpu_power_to_freq is used to find a frequency and set the
cooling device to consume at most the power to be converted. For example,
if the power to be converted is 80mW, and the em table is as follow.
struct em_cap_state table[] = {
/* KHz mW */
{ 1008000, 36, 0 },
{ 1200000, 49, 0 },
{ 1296000, 59, 0 },
{ 1416000, 72, 0 },
{ 1512000, 86, 0 },
};
The target frequency should be 1416000KHz, not 1512000KHz.
Fixes: 349d39dc57 ("thermal: cpu_cooling: merge frequency and power tables")
Cc: <stable@vger.kernel.org> # v4.13+
Signed-off-by: Finley Xiao <finley.xiao@rock-chips.com>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Amit Kucheria <amit.kucheria@linaro.org>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20200619090825.32747-1-finley.xiao@rock-chips.com
The Energy Model uses concept of performance domain and capacity states in
order to calculate power used by CPUs. Change naming convention from
capacity to performance state would enable wider usage in future, e.g.
upcoming support for other devices other than CPUs.
Acked-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Acked-by: Quentin Perret <qperret@google.com>
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
- Add interrupt support on the rcar sensor (Niklas Söderlund)
- Add a new Spreadtrum thermal driver (Baolin Wang)
- Add thermal binding for the fsl scu board, a new API to retrieve the
sensor id bound to the thermal zone and i.MX system controller
sensor (Anson Huang))
- Remove warning log when a deferred probe is requested on Exynos
(Marek Szyprowski)
- Add the thermal monitoring unit support for imx8mm with its DT
bindings (Anson Huang)
- Rephrase the Kconfig text for clarity (Linus Walleij)
- Use the gpio descriptor for the ti-soc-thermal (Linus Walleij)
- Align msg structure to 4 bytes for i.MX SC, fix the Kconfig
dependency, add the __may_be unused annotation for PM functions and
the COMPILE_TEST option for imx8mm (Anson Huang)
- Fix a dependency on regmap in Kconfig for qoriq (Yuantian Tang)
- Add DT binding and support for the rcar gen3 r8a77961 and improve
the error path on the rcar init function (Niklas Söderlund)
- Cleanup and improvements for the tsens Qcom sensor (Amit Kucheria)
- Improve code by removing lock and caching values in the rcar thermal
sensor (Niklas Söderlund)
- Cleanup in the qoriq drivers and add a call to
imx_thermal_unregister_legacy_cooling in the removal function (Anson
Huang)
- Remove redundant 'maxItems' in tsens and sprd DT bindings (Rob Herring)
- Change the thermal DT bindings by making the cooling-maps optional
(Yuantian Tang)
- Add Tiger Lake support (Sumeet Pawnikar)
- Use scnprintf() for avoiding potential buffer overflow (Takashi Iwai)
- Make pkg_temp_lock a raw_spinlock_t(Clark Williams)
- Fix incorrect data types by changing them to signed on i.MX SC (Anson Huang)
- Replace zero-length array with flexible-array member (Gustavo A. R. Silva)
- Add support for i.MX8MP in the driver and in the DT bindings (Anson Huang)
- Fix return value of the cpufreq_set_cur_state() function (Willy Wolff)
- Remove abusing and scary WARN_ON in the cpufreq cooling device
(Daniel Lezcano)
- Fix build warning of incorrect argument type reported by sparse on
imx8mm (Anson Huang)
- Fix stub for the devfreq cooling device (Martin Blumenstingl)
- Fix cpu idle cooling documentation (Sergey Vidishev)
-----BEGIN PGP SIGNATURE-----
iQEzBAABCAAdFiEEGn3N4YVz0WNVyHskqDIjiipP6E8FAl6MXkEACgkQqDIjiipP
6E+BIggAh52YBU8D8GthsvCPTgka95+wAIaZtx4Y7UnhvshHhM2w+m97TQOXK373
95mwO9mwQuAoksSmLo7pBQYJ7HItQ26Yoq9akpOL6EiT+BEWiqoHJgl+afVVtoKa
n67d3Pa6coup1+PQNIA8kpTIOmUQTP8THtwpZ3HlChWsg22NTd0QUGpGJ1TtBD/q
KqMdQjxahFJ4RTYsnECWBkw3EMkczMNMgdrXEvm4rMkcaJzv9g2ZPqerOShK/RzP
8sejWczt6jaRwu4hLpd/lLikTSHZoXMFJ8ylAiQXFELCPAQIrMS/ae+dTGJ4qP7x
hkjsewPbeA1Z+al/IBVHiCtOzKkICQ==
=XDYl
-----END PGP SIGNATURE-----
Merge tag 'thermal-v5.7-rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/thermal/linux
Pull thermal updates from Daniel Lezcano:
- Convert tsens configuration DT binding to yaml (Rajeshwari)
- Add interrupt support on the rcar sensor (Niklas Söderlund)
- Add a new Spreadtrum thermal driver (Baolin Wang)
- Add thermal binding for the fsl scu board, a new API to retrieve the
sensor id bound to the thermal zone and i.MX system controller sensor
(Anson Huang))
- Remove warning log when a deferred probe is requested on Exynos
(Marek Szyprowski)
- Add the thermal monitoring unit support for imx8mm with its DT
bindings (Anson Huang)
- Rephrase the Kconfig text for clarity (Linus Walleij)
- Use the gpio descriptor for the ti-soc-thermal (Linus Walleij)
- Align msg structure to 4 bytes for i.MX SC, fix the Kconfig
dependency, add the __may_be unused annotation for PM functions and
the COMPILE_TEST option for imx8mm (Anson Huang)
- Fix a dependency on regmap in Kconfig for qoriq (Yuantian Tang)
- Add DT binding and support for the rcar gen3 r8a77961 and improve the
error path on the rcar init function (Niklas Söderlund)
- Cleanup and improvements for the tsens Qcom sensor (Amit Kucheria)
- Improve code by removing lock and caching values in the rcar thermal
sensor (Niklas Söderlund)
- Cleanup in the qoriq drivers and add a call to
imx_thermal_unregister_legacy_cooling in the removal function (Anson
Huang)
- Remove redundant 'maxItems' in tsens and sprd DT bindings (Rob
Herring)
- Change the thermal DT bindings by making the cooling-maps optional
(Yuantian Tang)
- Add Tiger Lake support (Sumeet Pawnikar)
- Use scnprintf() for avoiding potential buffer overflow (Takashi Iwai)
- Make pkg_temp_lock a raw_spinlock_t(Clark Williams)
- Fix incorrect data types by changing them to signed on i.MX SC (Anson
Huang)
- Replace zero-length array with flexible-array member (Gustavo A. R.
Silva)
- Add support for i.MX8MP in the driver and in the DT bindings (Anson
Huang)
- Fix return value of the cpufreq_set_cur_state() function (Willy
Wolff)
- Remove abusing and scary WARN_ON in the cpufreq cooling device
(Daniel Lezcano)
- Fix build warning of incorrect argument type reported by sparse on
imx8mm (Anson Huang)
- Fix stub for the devfreq cooling device (Martin Blumenstingl)
- Fix cpu idle cooling documentation (Sergey Vidishev)
* tag 'thermal-v5.7-rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/thermal/linux: (52 commits)
Documentation: cpu-idle-cooling: Fix diagram for 33% duty cycle
thermal: devfreq_cooling: inline all stubs for CONFIG_DEVFREQ_THERMAL=n
thermal: imx8mm: Fix build warning of incorrect argument type
thermal/drivers/cpufreq_cooling: Remove abusing WARN_ON
thermal/drivers/cpufreq_cooling: Fix return of cpufreq_set_cur_state
thermal: imx8mm: Add i.MX8MP support
dt-bindings: thermal: imx8mm-thermal: Add support for i.MX8MP
thermal: qcom: tsens.h: Replace zero-length array with flexible-array member
thermal: imx_sc_thermal: Fix incorrect data type
thermal: int340x_thermal: Use scnprintf() for avoiding potential buffer overflow
thermal: int340x: processor_thermal: Add Tiger Lake support
thermal/x86_pkg_temp: Make pkg_temp_lock a raw_spinlock_t
dt-bindings: thermal: make cooling-maps property optional
dt-bindings: thermal: qcom-tsens: Remove redundant 'maxItems'
dt-bindings: thermal: sprd: Remove redundant 'maxItems'
thermal: imx: Calling imx_thermal_unregister_legacy_cooling() in .remove
thermal: qoriq: Sort includes alphabetically
thermal: qoriq: Use devm_add_action_or_reset() to handle all cleanups
thermal: rcar_thermal: Remove lock in rcar_thermal_get_current_temp()
thermal: rcar_thermal: Do not store ctemp in rcar_thermal_priv
...
The WARN_ON macros are used at the entry functions state2power() and
set_cur_state().
state2power() is called with the max_state retrieved from
get_max_state which returns cpufreq_cdev->max_level, then it check if
max_state is > cpufreq_cdev->max_level. The test does not really makes
sense but let's assume we want to make sure to catch an error if the
code evolves. However the WARN_ON is overkill.
set_cur_state() is also called from userspace if we write to the
sysfs. It is easy to see a stack dumped by just writing to sysfs
/sys/class/thermal/cooling_device0/cur_state a value greater than
"max_level". A bit scary. Returing -EINVAL is enough.
Remove these WARN_ON.
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Link: https://lore.kernel.org/r/20200321193107.21590-1-daniel.lezcano@linaro.org
When setting the cooling device current state from userspace via sysfs,
the operation fails by returning an -EINVAL.
It appears the recent changes with the per-policy frequency QoS
introduced a regression as reported by:
https://lkml.org/lkml/2020/3/20/599
The function freq_qos_update_request returns 0 or 1 describing update
effectiveness, and a negative error code on failure. However,
cpufreq_set_cur_state returns 0 on success or an error code otherwise.
Consider the QoS update as successful if the function does not return
an error.
Fixes: 3000ce3c52 ("cpufreq: Use per-policy frequency QoS")
Signed-off-by: Willy Wolff <willy.mh.wolff.ml@gmail.com>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20200321092740.7vvwfxsebcrznydh@macmini.local
Thermal governors can request for a CPU's maximum supported frequency to
be capped in case of an overheat event. This in turn means that the
maximum capacity available for tasks to run on the particular CPU is
reduced. Delta between the original maximum capacity and capped maximum
capacity is known as thermal pressure. Enable cpufreq cooling device to
update the thermal pressure in event of a capped maximum frequency.
Signed-off-by: Thara Gopinath <thara.gopinath@linaro.org>
Signed-off-by: Peter Zijlstra (Intel) <peterz@infradead.org>
Signed-off-by: Ingo Molnar <mingo@kernel.org>
Link: https://lkml.kernel.org/r/20200222005213.3873-9-thara.gopinath@linaro.org
As we introduced the idle injection cooling device called
cpuidle_cooling, let's be consistent and rename the cpu_cooling to
cpufreq_cooling as this one mitigates with OPPs changes.
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Amit Kucheria <amit.kucheria@linaro.org>
Link: https://lore.kernel.org/r/20191219225317.17158-3-daniel.lezcano@linaro.org