Commit Graph

267 Commits

Author SHA1 Message Date
Jason Gerecke
f77810f744 HID: wacom: Fix logic used for 3rd barrel switch emulation
When support was added for devices using an explicit 3rd barrel switch,
the logic used by devices emulating this feature was broken. The 'if'
statement / block that was introduced only handles the case where the
button is pressed (i.e. 'barrelswitch' and 'barrelswitch2' are both set)
but not the case where it is released (i.e. one or both being cleared).
This results in a BTN_STYLUS3 "down" event being sent when the button
is pressed, but no "up" event ever being sent afterwards.

This patch restores the previously-used logic for determining button
states in the emulated case so that switches are reported correctly
again.

Link: https://github.com/linuxwacom/xf86-input-wacom/issues/292
Fixes: 6d09085b38 ("HID: wacom: Adding Support for new usages")
CC: stable@vger.kernel.org #v5.19+
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Tested-by: Joshua Dickens <joshua.dickens@wacom.com>
Reviewed-by: Ping Cheng <ping.cheng@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2022-11-04 09:34:38 +01:00
Benjamin Tissoires
1af52d6b35 Merge branch 'for-6.1/wacom' into for-linus
- Simplify comments (Christophe JAILLET)
2022-10-05 10:36:30 +01:00
Ping Cheng
bfdc750c4c HID: wacom: add three styli to wacom_intuos_get_tool_type
We forgot to add the 3D pen ID a year ago. There are two new pro pen
IDs to be added.

Signed-off-by: Ping Cheng <ping.cheng@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2022-09-30 11:08:15 +02:00
Ping Cheng
0627f3df95 HID: wacom: Add new Intuos Pro Small (PTH-460) device IDs
Add the new PIDs to wacom_wac.c to support the new model in the Intuos Pro series.

Signed-off-by: Ping Cheng <ping.cheng@wacom.com>
Tested-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2022-09-02 12:00:24 +02:00
Christophe JAILLET
35f473864f HID: wacom: Simplify comments
Remove a left-over from commit 2874c5fd28 ("treewide: Replace GPLv2
boilerplate/reference with SPDX - rule 152").
An empty comment block can be removed.

While at it remove, also remove what is supposed to be the path/filename of
the file.
This is really low value... and wrong since commit 471d17148c
("Input: wacom - move the USB (now hid) Wacom driver in drivers/hid")

Signed-off-by: Christophe JAILLET <christophe.jaillet@wanadoo.fr>
Reviewed-by: Ping Cheng <ping.cheng@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2022-08-25 11:32:31 +02:00
Jason Gerecke
94b179052f HID: wacom: Force pen out of prox if no events have been received in a while
Prox-out events may not be reliably sent by some AES firmware. This can
cause problems for users, particularly due to arbitration logic disabling
touch input while the pen is in prox.

This commit adds a timer which is reset every time a new prox event is
received. When the timer expires we check to see if the pen is still in
prox and force it out if necessary. This is patterend off of the same
solution used by 'hid-letsketch' driver which has a similar problem.

Link: https://github.com/linuxwacom/input-wacom/issues/310
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2022-07-21 13:49:32 +02:00
Ping Cheng
d6b675687a HID: wacom: Don't register pad_input for touch switch
Touch switch state is received through WACOM_PAD_FIELD. However, it
is reported by touch_input. Don't register pad_input if no other pad
events require the interface.

Cc: stable@vger.kernel.org
Signed-off-by: Ping Cheng <ping.cheng@wacom.com>
Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2022-05-27 09:05:50 +02:00
Ping Cheng
7ccced33a0 HID: wacom: Only report rotation for art pen
The generic routine, wacom_wac_pen_event, turns rotation value 90
degree anti-clockwise before posting the events. This non-zero
event trggers a non-zero ABS_Z event for non art pen tools. However,
HID_DG_TWIST is only supported by art pen.

[jkosina@suse.cz: fix build: add missing brace]
Cc: stable@vger.kernel.org
Signed-off-by: Ping Cheng <ping.cheng@wacom.com>
Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com>
--
Hi Jiri,

This is kind of a version 2 of the last one I posted two days ago.
I updated the logic so it has less changed lines: 29 vs 158! Hopefully,
the logic is easier to follow now. Please ignore the last one.

Thank you!
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2022-05-27 09:05:31 +02:00
Joshua-Dickens
d88591a555 Hid: wacom: Fix kernel test robot warning
Kernel test robot throws the following warning -
>> drivers/hid/wacom_wac.c:2411:42: warning: format specifies type 'unsigned short' but the argument has type 'int' [-Wformat]
                           hid_warn(hdev, "Dropped %hu packets", value - wacom_wac->hid_data.sequence_number);
                                                   ~~~           ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
                                                   %d

Explicitly casting the argument to unsigned short to silence the warning and retain the intended behavior.

Reported-by: kernel test robot <lkp@intel.com>
Signed-off-by: Joshua Dickens <joshua.dickens@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2022-05-06 08:36:28 +02:00
Joshua-Dickens
6d09085b38 HID: wacom: Adding Support for new usages
Added supprt for the following usages:
* HID_DG_SCANTIME to report the timestamp for pen and touch events.
* WACOM_HID_WD_BARRELSWITCH3 to support pens with 3 buttons.
* WACOM_HID_WD_SEQUENCENUMBER to detect and report dropped packets.

Signed-off-by: Joshua Dickens <joshua.dickens@wacom.com>
Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2022-04-21 09:42:32 +02:00
Jason Gerecke
20f3cf5f86 HID: wacom: Avoid using stale array indicies to read contact count
If we ever see a touch report with contact count data we initialize
several variables used to read the contact count in the pre-report
phase. These variables are never reset if we process a report which
doesn't contain a contact count, however. This can cause the pre-
report function to trigger a read of arbitrary memory (e.g. NULL
if we're lucky) and potentially crash the driver.

This commit restores resetting of the variables back to default
"none" values that were used prior to the commit mentioned
below.

Link: https://github.com/linuxwacom/input-wacom/issues/276
Fixes: 003f50ab67 (HID: wacom: Update last_slot_field during pre_report phase)
CC: stable@vger.kernel.org
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Reviewed-by: Ping Cheng <ping.cheng@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2022-01-21 15:10:02 +01:00
Jason Gerecke
df03e9bd6d HID: wacom: Ignore the confidence flag when a touch is removed
AES hardware may internally re-classify a contact that it thought was
intentional as a palm. Intentional contacts are reported as "down" with
the confidence bit set. When this re-classification occurs, however, the
state transitions to "up" with the confidence bit cleared. This kind of
transition appears to be legal according to Microsoft docs, but we do
not handle it correctly. Because the confidence bit is clear, we don't
call `wacom_wac_finger_slot` and update userspace. This causes hung
touches that confuse userspace and interfere with pen arbitration.

This commit adds a special case to ignore the confidence flag if a contact
is reported as removed. This ensures we do not leave a hung touch if one
of these re-classification events occured. Ideally we'd have some way to
also let userspace know that the touch has been re-classified as a palm
and needs to be canceled, but that's not possible right now :)

Link: https://github.com/linuxwacom/input-wacom/issues/288
Fixes: 7fb0413baa (HID: wacom: Use "Confidence" flag to prevent reporting invalid contacts)
CC: stable@vger.kernel.org
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Reviewed-by: Ping Cheng <ping.cheng@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2022-01-21 15:10:02 +01:00
Jason Gerecke
546e41ac99 HID: wacom: Reset expected and received contact counts at the same time
These two values go hand-in-hand and must be valid for the driver to
behave correctly. We are currently lazy about updating the values and
rely on the "expected" code flow to take care of making sure they're
valid at the point they're needed. The "expected" flow changed somewhat
with commit f8b6a74719 ("HID: wacom: generic: Support multiple tools
per report"), however. This led to problems with the DTH-2452 due (in
part) to *all* contacts being fully processed -- even those past the
expected contact count. Specifically, the received count gets reset to
0 once all expected fingers are processed, but not the expected count.
The rest of the contacts in the report are then *also* processed since
now the driver thinks we've only processed 0 of N expected contacts.

Later commits such as 7fb0413baa (HID: wacom: Use "Confidence" flag to
prevent reporting invalid contacts) worked around the DTH-2452 issue by
skipping the invalid contacts at the end of the report, but this is not
a complete fix. The confidence flag cannot be relied on when a contact
is removed (see the following patch), and dealing with that condition
re-introduces the DTH-2452 issue unless we also address this contact
count laziness. By resetting expected and received counts at the same
time we ensure the driver understands that there are 0 more contacts
expected in the report. Similarly, we also make sure to reset the
received count if for some reason we're out of sync in the pre-report
phase.

Link: https://github.com/linuxwacom/input-wacom/issues/288
Fixes: f8b6a74719 ("HID: wacom: generic: Support multiple tools per report")
CC: stable@vger.kernel.org
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Reviewed-by: Ping Cheng <ping.cheng@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2022-01-21 15:10:02 +01:00
Jason Gerecke
7fb0413baa HID: wacom: Use "Confidence" flag to prevent reporting invalid contacts
The HID descriptor of many of Wacom's touch input devices include a
"Confidence" usage that signals if a particular touch collection contains
useful data. The driver does not look at this flag, however, which causes
even invalid contacts to be reported to userspace. A lucky combination of
kernel event filtering and device behavior (specifically: contact ID 0 ==
invalid, contact ID >0 == valid; and order all data so that all valid
contacts are reported before any invalid contacts) spare most devices from
any visibly-bad behavior.

The DTH-2452 is one example of an unlucky device that misbehaves. It uses
ID 0 for both the first valid contact and all invalid contacts. Because
we report both the valid and invalid contacts, the kernel reports that
contact 0 first goes down (valid) and then goes up (invalid) in every
report. This causes ~100 clicks per second simply by touching the screen.

This patch inroduces new `confidence` flag in our `hid_data` structure.
The value is initially set to `true` at the start of a report and can be
set to `false` if an invalid touch usage is seen.

Link: https://github.com/linuxwacom/input-wacom/issues/270
Fixes: f8b6a74719 ("HID: wacom: generic: Support multiple tools per report")
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Tested-by: Joshua Dickens <joshua.dickens@wacom.com>
Cc: <stable@vger.kernel.org>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2021-11-10 10:02:06 +01:00
Joshua-Dickens
0c8fbaa553 HID: wacom: Add new Intuos BT (CTL-4100WL/CTL-6100WL) device IDs
Add the new PIDs to wacom_wac.c to support the new models in the Intuos series.

[jkosina@suse.cz: fix changelog]
Signed-off-by: Joshua Dickens <joshua.dickens@wacom.com>
Reviewed-by: Ping Cheng <ping.cheng@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2021-09-15 17:20:15 +02:00
Jason Gerecke
9d339fe4cb HID: wacom: Refactor touch input mute checks into a common function
We perform this same set of tests to see if touch input is muted in
several places. We might as well replace these independent copies with
an inline function.

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2021-07-28 11:45:41 +02:00
Jason Gerecke
ccb51c2e3f HID: wacom: Avoid sending empty sync events
Empty sync events clutter up logs and are a waste of CPU cycles. We can
avoid sending mt_sync events if touch is disabled or a specific slot is
unused. We can avoid sending full sync events if no events were generated.

Signed-off-by: Ping Cheng <ping.cheng@wacom.com>
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2021-07-28 11:45:40 +02:00
Jason Gerecke
5bed012886 HID: wacom: Short-circuit processing of touch when it is disabled
Avoid doing unnecessary work when touch is disabled by detecting this
condition and returning early. Note that the probe process sends GET
FEATURE requests to discover e.g. HID_DG_CONTACTMAX, so we can't start
ignoring touch reports until probe finishes.

Signed-off-by: Ping Cheng <ping.cheng@wacom.com>
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2021-07-28 11:45:40 +02:00
Ping Cheng
dc9dc864f3 HID: wacom: set initial hardware touch switch state to 'off'
Wacom touch devices have two types of touch switches: softkey touch
toggle and hardware touch switch. For softkey toggle, we assume
touch is on by default in the driver. However the hardware touch
switch is controlled by end users. We don't know if it's on or off
before getting the status event.

This patch sets touch off for devices with a hardware switch until we
get the status. This is a bit safer for users who leave the switch "off"
and don't want any accidental touches. The tradeoff is a slight delay
between device connection and touch becoming enabled for users who
leave the switch "on".

Signed-off-by: Ping Cheng <ping.cheng@wacom.com>
Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com>
Tested-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2021-07-28 11:45:40 +02:00
Jason Gerecke
7cc8524f65 HID: wacom: Skip processing of touches with negative slot values
The `input_mt_get_slot_by_key` function may return a negative value
if an error occurs (e.g. running out of slots). If this occurs we
should really avoid reporting any data for the slot.

Signed-off-by: Ping Cheng <ping.cheng@wacom.com>
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2021-07-28 11:43:48 +02:00
Jason Gerecke
6ca2350e11 HID: wacom: Re-enable touch by default for Cintiq 24HDT / 27QHDT
Commit 670e90924b ("HID: wacom: support named keys on older devices")
added support for sending named events from the soft buttons on the
24HDT and 27QHDT. In the process, however, it inadvertantly disabled the
touchscreen of the 24HDT and 27QHDT by default. The
`wacom_set_shared_values` function would normally enable touch by default
but because it checks the state of the non-shared `has_mute_touch_switch`
flag and `wacom_setup_touch_input_capabilities` sets the state of the
/shared/ version, touch ends up being disabled by default.

This patch sets the non-shared flag, letting `wacom_set_shared_values`
take care of copying the value over to the shared version and setting
the default touch state to "on".

Fixes: 670e90924b ("HID: wacom: support named keys on older devices")
CC: stable@vger.kernel.org # 5.4+
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Reviewed-by: Ping Cheng <ping.cheng@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2021-07-28 11:43:48 +02:00
Jiri Kosina
6c905ab1ac Merge branch 'for-5.13/wacom' into for-linus
- Wacom pen handling fix from Ping Cheng
2021-04-29 21:47:03 +02:00
Ping Cheng
46fc466e01 HID: wacom: Setup pen input capabilities to the targeted tools
Only set the bits that are supported by the targeted devices.
This patch also removes duplicated set_bit calls.

Signed-off-by: Ping Cheng <ping.cheng@wacom.com>
Reviewed-by: Jason Gerecke <Jason.Gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2021-04-13 08:19:41 +02:00
Ping Cheng
276559d8d0 HID: wacom: set EV_KEY and EV_ABS only for non-HID_GENERIC type of devices
Valid HID_GENERIC type of devices set EV_KEY and EV_ABS by wacom_map_usage.
When *_input_capabilities are reached, those devices should already have
their proper EV_* set. EV_KEY and EV_ABS only need to be set for
non-HID_GENERIC type of devices in *_input_capabilities.

Devices that don't support HID descitoprs will pass back to hid-input for
registration without being accidentally rejected by the introduction of
patch: "Input: refuse to register absolute devices without absinfo"

Fixes: 6ecfe51b40 ("Input: refuse to register absolute devices without absinfo")
Signed-off-by: Ping Cheng <ping.cheng@wacom.com>
Reviewed-by: Jason Gerecke <Jason.Gerecke@wacom.com>
Tested-by: Juan Garrido <Juan.Garrido@wacom.com>
CC: stable@vger.kernel.org
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2021-03-16 15:41:20 +01:00
Jiapeng Zhong
e29c62ffb0 HID: wacom: Assign boolean values to a bool variable
Fix the following coccicheck warnings:

./drivers/hid/wacom_wac.c:2536:2-6: WARNING: Assignment of
0/1 to bool variable.

Reported-by: Abaci Robot <abaci@linux.alibaba.com>
Signed-off-by: Jiapeng Zhong <abaci-bugfix@linux.alibaba.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2021-03-08 14:57:00 +01:00
Jason Gerecke
88f38846bf HID: wacom: Ignore attempts to overwrite the touch_max value from HID
The `wacom_feature_mapping` function is careful to only set the the
touch_max value a single time, but this care does not extend to the
`wacom_wac_finger_event` function. In particular, if a device sends
multiple HID_DG_CONTACTMAX items in a single feature report, the
driver will end up retaining the value of last item.

The HID descriptor for the Cintiq Companion 2 does exactly this. It
incorrectly sets a "Report Count" of 2, which will cause the driver
to process two HID_DG_CONTACTCOUNT items. The first item has the actual
count, while the second item should have been declared as a constant
zero. The constant zero is the value the driver ends up using, however,
since it is the last HID_DG_CONTACTCOUNT in the report.

    Report ID (16),
    Usage (Contact Count Maximum),  ; Contact count maximum (55h, static value)
    Report Count (2),
    Logical Maximum (10),
    Feature (Variable),

To address this, we add a check that the touch_max is not already set
within the `wacom_wac_finger_event` function that processes the
HID_DG_TOUCHMAX item. We emit a warning if the value is set and ignore
the updated value.

This could potentially cause problems if there is a tablet which has
a similar issue but requires the last item to be used. This is unlikely,
however, since it would have to have a different non-zero value for
HID_DG_CONTACTMAX earlier in the same report, which makes no sense
except in the case of a firmware bug. Note that cases where the
HID_DG_CONTACTMAX items are in different reports is already handled
(and similarly ignored) by `wacom_feature_mapping` as mentioned above.

Link: https://github.com/linuxwacom/input-wacom/issues/223
Fixes: 184eccd403 ("HID: wacom: generic: read HID_DG_CONTACTMAX from any feature report")
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
CC: stable@vger.kernel.org
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2021-02-18 09:36:17 +01:00
Jiri Kosina
9b14b06679 Merge branch 'for-5.9/upstream-fixes' into for-linus
- "heartbeat" report fix for several Wacom devices
- Lenovo X1 Tablet support improvements
- new device IDs
- bounds checking fix in hid-roccat
- stylus battery reporting fix
2020-10-15 20:41:43 +02:00
Jason Gerecke
d9216d753b HID: wacom: Avoid entering wacom_wac_pen_report for pad / battery
It has recently been reported that the "heartbeat" report from devices
like the 2nd-gen Intuos Pro (PTH-460, PTH-660, PTH-860) or the 2nd-gen
Bluetooth-enabled Intuos tablets (CTL-4100WL, CTL-6100WL) can cause the
driver to send a spurious BTN_TOUCH=0 once per second in the middle of
drawing. This can result in broken lines while drawing on Chrome OS.

The source of the issue has been traced back to a change which modified
the driver to only call `wacom_wac_pad_report()` once per report instead
of once per collection. As part of this change, pad-handling code was
removed from `wacom_wac_collection()` under the assumption that the
`WACOM_PEN_FIELD` and `WACOM_TOUCH_FIELD` checks would not be satisfied
when a pad or battery collection was being processed.

To be clear, the macros `WACOM_PAD_FIELD` and `WACOM_PEN_FIELD` do not
currently check exclusive conditions. In fact, most "pad" fields will
also appear to be "pen" fields simply due to their presence inside of
a Digitizer application collection. Because of this, the removal of
the check from `wacom_wac_collection()` just causes pad / battery
collections to instead trigger a call to `wacom_wac_pen_report()`
instead. The pen report function in turn resets the tip switch state
just prior to exiting, resulting in the observed BTN_TOUCH=0 symptom.

To correct this, we restore a version of the `WACOM_PAD_FIELD` check
in `wacom_wac_collection()` and return early. This effectively prevents
pad / battery collections from being reported until the very end of the
report as originally intended.

Fixes: d4b8efeb46 ("HID: wacom: generic: Correct pad syncing")
Cc: stable@vger.kernel.org # v4.17+
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Reviewed-by: Ping Cheng <ping.cheng@wacom.com>
Tested-by: Ping Cheng <ping.cheng@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2020-09-25 13:14:16 +02:00
Gustavo A. R. Silva
df561f6688 treewide: Use fallthrough pseudo-keyword
Replace the existing /* fall through */ comments and its variants with
the new pseudo-keyword macro fallthrough[1]. Also, remove unnecessary
fall-through markings when it is the case.

[1] https://www.kernel.org/doc/html/v5.7/process/deprecated.html?highlight=fallthrough#implicit-switch-case-fall-through

Signed-off-by: Gustavo A. R. Silva <gustavoars@kernel.org>
2020-08-23 17:36:59 -05:00
Jason Gerecke
dcce8ef8f7 HID: wacom: Report 2nd-gen Intuos Pro S center button status over BT
The state of the center button was not reported to userspace for the
2nd-gen Intuos Pro S when used over Bluetooth due to the pad handling
code not being updated to support its reduced number of buttons. This
patch uses the actual number of buttons present on the tablet to
assemble a button state bitmap.

Link: https://github.com/linuxwacom/xf86-input-wacom/issues/112
Fixes: cd47de45b855 ("HID: wacom: Add 2nd gen Intuos Pro Small support")
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Cc: stable@vger.kernel.org # v5.3+
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2020-04-29 21:40:53 +02:00
Jason Gerecke
b43f977dd2 Revert "HID: wacom: generic: read the number of expected touches on a per collection basis"
This reverts commit 15893fa401.

The referenced commit broke pen and touch input for a variety of devices
such as the Cintiq Pro 32. Affected devices may appear to work normally
for a short amount of time, but eventually loose track of actual touch
state and can leave touch arbitration enabled which prevents the pen
from working. The commit is not itself required for any currently-available
Bluetooth device, and so we revert it to correct the behavior of broken
devices.

This breakage occurs due to a mismatch between the order of collections
and the order of usages on some devices. This commit tries to read the
contact count before processing events, but will fail if the contact
count does not occur prior to the first logical finger collection. This
is the case for devices like the Cintiq Pro 32 which place the contact
count at the very end of the report.

Without the contact count set, touches will only be partially processed.
The `wacom_wac_finger_slot` function will not open any slots since the
number of contacts seen is greater than the expectation of 0, but we will
still end up calling `input_mt_sync_frame` for each finger anyway. This
can cause problems for userspace separate from the issue currently taking
place in the kernel. Only once all of the individual finger collections
have been processed do we finally get to the enclosing collection which
contains the contact count. The value ends up being used for the *next*
report, however.

This delayed use of the contact count can cause the driver to loose track
of the actual touch state and believe that there are contacts down when
there aren't. This leaves touch arbitration enabled and prevents the pen
from working. It can also cause userspace to incorrectly treat single-
finger input as gestures.

Link: https://github.com/linuxwacom/input-wacom/issues/146
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Reviewed-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com>
Fixes: 15893fa401 ("HID: wacom: generic: read the number of expected touches on a per collection basis")
Cc: stable@vger.kernel.org # 5.3+
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2020-04-16 21:38:47 +02:00
Jason Gerecke
fe4e940f0f HID: wacom: Recognize new MobileStudio Pro PID
A new PID is in use for repaired MobileStudio Pro devices. Add it to the
list of devices that need special-casing in wacom_wac_pad_event.

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
2019-12-18 15:24:26 +01:00
Jason Gerecke
ff479731c3 HID: wacom: generic: Treat serial number and related fields as unsigned
The HID descriptors for most Wacom devices oddly declare the serial
number and other related fields as signed integers. When these numbers
are ingested by the HID subsystem, they are automatically sign-extended
into 32-bit integers. We treat the fields as unsigned elsewhere in the
kernel and userspace, however, so this sign-extension causes problems.
In particular, the sign-extended tool ID sent to userspace as ABS_MISC
does not properly match unsigned IDs used by xf86-input-wacom and libwacom.

We introduce a function 'wacom_s32tou' that can undo the automatic sign
extension performed by 'hid_snto32'. We call this function when processing
the serial number and related fields to ensure that we are dealing with
and reporting the unsigned form. We opt to use this method rather than
adding a descriptor fixup in 'wacom_hid_usage_quirk' since it should be
more robust in the face of future devices.

Ref: https://github.com/linuxwacom/input-wacom/issues/134
Fixes: f85c9dc678 ("HID: wacom: generic: Support tool ID and additional tool types")
CC: <stable@vger.kernel.org> # v4.10+
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Reviewed-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-11-06 21:37:29 +01:00
Jiri Kosina
8ca06d6f2d Merge branch 'for-5.4/wacom' into for-linus
- MobileStudio Pro 13 support, from Ping Cheng

- a few other assorted fixes

Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-09-22 22:42:41 +02:00
Ping Cheng
bbbe3ac8f9 HID: wacom: add new MobileStudio Pro 13 support
wacom_wac_pad_event is the only routine we need to update.

Signed-off-by: Ping Cheng <ping.cheng@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-09-05 15:01:39 +02:00
Aaron Armstrong Skomra
670e90924b HID: wacom: support named keys on older devices
Some Wacom devices have keys with predefined meanings. However, when
support was originally added for these devices, the codes for these
keys were not available yet. These keys were thus reported with
the numbered KEY_PROG* range.

Some missing key codes were added with commit 4eb220cb35 ("HID:
wacom: generic: add 3 tablet touch keys") and we are now able to
report the proper key codes. We continue to report the original
KEY_PROG codes so as not to break any unknown applications that
may depend on them.

Also, to support the touch key, track its state in the pad report.

Signed-off-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com>
Link: https://gitlab.freedesktop.org/libinput/libinput/merge_requests/155
Link: https://github.com/linuxwacom/xf86-input-wacom/pull/46
Reviewed-by: Ping Cheng <ping.cheng@wacom.com>
Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-08-20 16:59:05 +02:00
Jason Gerecke
073b50bccb HID: wacom: Fix several minor compiler warnings
Addresses a few issues that were noticed when compiling with non-default
warnings enabled. The trimmed-down warnings in the order they are fixed
below are:

* declaration of 'size' shadows a parameter

* '%s' directive output may be truncated writing up to 5 bytes into a
  region of size between 1 and 64

* pointer targets in initialization of 'char *' from 'unsigned char *'
  differ in signedness

* left shift of negative value

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Reviewed-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-08-20 16:57:31 +02:00
Aaron Armstrong Skomra
fcf887e7ca HID: wacom: correct misreported EKR ring values
The EKR ring claims a range of 0 to 71 but actually reports
values 1 to 72. The ring is used in relative mode so this
change should not affect users.

Signed-off-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com>
Fixes: 72b236d602 ("HID: wacom: Add support for Express Key Remote.")
Cc: <stable@vger.kernel.org> # v4.3+
Reviewed-by: Ping Cheng <ping.cheng@wacom.com>
Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-08-20 10:40:40 +02:00
Jason Gerecke
b72fb1dcd2 HID: wacom: Correct distance scale for 2nd-gen Intuos devices
Distance values reported by 2nd-gen Intuos tablets are on an inverted
scale (0 == far, 63 == near). We need to change them over to a normal
scale before reporting to userspace or else userspace drivers and
applications can get confused.

Ref: https://github.com/linuxwacom/input-wacom/issues/98
Fixes: eda01dab53 ("HID: wacom: Add four new Intuos devices")
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Cc: <stable@vger.kernel.org> # v4.4+
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-08-19 14:08:58 +02:00
Aaron Armstrong Skomra
7cdf6e4053 HID: wacom: add back changes dropped in merge commit
Merge commit 74acee309f ("Merge branches 'for-5.2/fixes', 'for-5.3/doc',
'for-5.3/ish', 'for-5.3/logitech' and 'for-5.3/wacom' into for-linus")
inadvertently dropped this change from commit 912c6aa67a
("HID: wacom: Add 2nd gen Intuos Pro Small support").

Signed-off-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-08-13 10:52:24 +02:00
Aaron Armstrong Skomra
693c3dab4e HID: wacom: fix bit shift for Cintiq Companion 2
The bit indicating BTN_6 on this device is overshifted
by 2 bits, resulting in the incorrect button being
reported.

Also fix copy-paste mistake in comments.

Signed-off-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com>
Reviewed-by: Ping Cheng <ping.cheng@wacom.com>
Link: https://github.com/linuxwacom/xf86-input-wacom/issues/71
Fixes: c7f0522a1a ("HID: wacom: Slim down wacom_intuos_pad processing")
Cc: <stable@vger.kernel.org> # v4.5+
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-08-05 14:13:41 +02:00
Jiri Kosina
74acee309f Merge branches 'for-5.2/fixes', 'for-5.3/doc', 'for-5.3/ish', 'for-5.3/logitech' and 'for-5.3/wacom' into for-linus 2019-07-10 01:39:57 +02:00
Aaron Armstrong Skomra
6e2abc6858 HID: wacom: generic: add touchring adjustment for 2nd Gen Pro Small
Add the product ID for the 2nd Generation Intuos Pro
Small to the touchring coordinate adjustment block.

Signed-off-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com>
Reviewed-by: Ping Cheng <ping.cheng@wacom.com>
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
2019-07-02 10:21:34 +02:00
Ping Cheng
384225c2a7 HID: wacom: add new MobileStudio Pro support
Add product ID for new MobileStudio Pro.

Signed-off-by: Ping Cheng <ping.cheng@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-06-26 14:00:32 +02:00
Linus Torvalds
c11fb13a11 Merge branch 'for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/hid/hid
Pull HID fixes from Jiri Kosina:

 - regression fixes (reverts) for module loading changes that turned out
   to be incompatible with some userspace, from Benjamin Tissoires

 - regression fix for special Logitech unifiying receiver 0xc52f, from
   Hans de Goede

 - a few device ID additions to logitech driver, from Hans de Goede

 - fix for Bluetooth support on 2nd-gen Wacom Intuos Pro, from Jason
   Gerecke

* 'for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/hid/hid:
  HID: logitech-dj: Fix 064d:c52f receiver support
  Revert "HID: core: Call request_module before doing device_add"
  Revert "HID: core: Do not call request_module() in async context"
  Revert "HID: Increase maximum report size allowed by hid_field_extract()"
  HID: a4tech: fix horizontal scrolling
  HID: hyperv: Add a module description line
  HID: logitech-hidpp: Add support for the S510 remote control
  HID: multitouch: handle faulty Elo touch device
  HID: wacom: Sync INTUOSP2_BT touch state after each frame if necessary
  HID: wacom: Correct button numbering 2nd-gen Intuos Pro over Bluetooth
  HID: wacom: Send BTN_TOUCH in response to INTUOSP2_BT eraser contact
  HID: wacom: Don't report anything prior to the tool entering range
  HID: wacom: Don't set tool type until we're in range
  HID: rmi: Use SET_REPORT request on control endpoint for Acer Switch 3 and 5
  HID: logitech-hidpp: add support for the MX5500 keyboard
  HID: logitech-dj: add support for the Logitech MX5500's Bluetooth Mini-Receiver
  HID: i2c-hid: add iBall Aer3 to descriptor override
2019-06-13 05:59:05 -10:00
Aaron Armstrong Skomra
15893fa401 HID: wacom: generic: read the number of expected touches on a per collection basis
Bluetooth connections may contain more than one set of touches,
or a partial set of touches, in one report.

Set the number of expected touches when reading a collection
instead of once per report (in the pre-report function).

Accordingly, reset the number of touches expected after each sync.

Signed-off-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-06-13 16:48:50 +02:00
Aaron Armstrong Skomra
f4e11d5996 HID: wacom: generic: support the 'report valid' usage for touch
Finger data is separated into chunks in our Bluetooth report,
where each report contains the same number of chunks. Those chunks
are not aligned in any particular way to a set of finger touches.
That is, the first half of a group of simultaneous touches may
be in one chunk at the end of a report and the second half could
be at the beginning of the next report.

Also some chunks contain no data and potentially some chunks could
contain leftover (bad) data.

Introduce and process the WACOM_HID_WT_REPORT_VALID usage that the
device uses to let us know if we should process a chunk of data.

Signed-off-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-06-13 16:48:49 +02:00
Aaron Armstrong Skomra
184eccd403 HID: wacom: generic: read HID_DG_CONTACTMAX from any feature report
In the generic code path, HID_DG_CONTACTMAX was previously
only read from the second byte of report 0x23.

Another report (0x82) has the HID_DG_CONTACTMAX in the
higher nibble of the third byte. We should support reading the
value of HID_DG_CONTACTMAX no matter what report we are reading
or which position that value is in.

To do this we submit the feature report as a event report
using hid_report_raw_event(). Our modified finger event path
records the value of HID_DG_CONTACTMAX when it sees that usage.

Fixes: 8ffffd5212 ("HID: wacom: fix timeout on probe for some wacoms")
Signed-off-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-06-13 16:48:49 +02:00
Aaron Armstrong Skomra
912c6aa67a HID: wacom: Add 2nd gen Intuos Pro Small support
The existing INTUOSP2_BT device class supports LEDs and this device
does not. A new device class enum entry, "INTUOSP2S_BT", is created
to avoid the INTUOSP2_BT LED code.

Signed-off-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com>
Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-06-13 16:48:49 +02:00
Thomas Gleixner
2874c5fd28 treewide: Replace GPLv2 boilerplate/reference with SPDX - rule 152
Based on 1 normalized pattern(s):

  this program is free software you can redistribute it and or modify
  it under the terms of the gnu general public license as published by
  the free software foundation either version 2 of the license or at
  your option any later version

extracted by the scancode license scanner the SPDX license identifier

  GPL-2.0-or-later

has been chosen to replace the boilerplate/reference in 3029 file(s).

Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Reviewed-by: Allison Randal <allison@lohutok.net>
Cc: linux-spdx@vger.kernel.org
Link: https://lkml.kernel.org/r/20190527070032.746973796@linutronix.de
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2019-05-30 11:26:32 -07:00