mac80211: fix vif name tracing

If sdata doesn't have a valid dev (e.g. in case of monitor
vif), the vif_name field was initialized with (a length of)
some short string, but later was set to a different,
potentially larger one.

This resulted in out-of-bounds write, which usually
appeared as garbage in the trace log.

Simply trace sdata->name, as it should always have the
correct name for both cases.

Signed-off-by: Eliad Peller <eliadx.peller@intel.com>
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
This commit is contained in:
Eliad Peller 2014-02-26 14:46:35 +02:00 committed by Johannes Berg
parent 4a817aa78f
commit f9ac71bfcc

View File

@ -21,10 +21,10 @@
#define VIF_ENTRY __field(enum nl80211_iftype, vif_type) __field(void *, sdata) \
__field(bool, p2p) \
__string(vif_name, sdata->dev ? sdata->dev->name : "<nodev>")
__string(vif_name, sdata->name)
#define VIF_ASSIGN __entry->vif_type = sdata->vif.type; __entry->sdata = sdata; \
__entry->p2p = sdata->vif.p2p; \
__assign_str(vif_name, sdata->dev ? sdata->dev->name : sdata->name)
__assign_str(vif_name, sdata->name)
#define VIF_PR_FMT " vif:%s(%d%s)"
#define VIF_PR_ARG __get_str(vif_name), __entry->vif_type, __entry->p2p ? "/p2p" : ""