ARM: DRA7: Resue the clocksource, clockevent support

All of OMAP5 timer support for clocksource and clockevent is completely
reused across DRA7.

Signed-off-by: R Sricharan <r.sricharan@ti.com>
Signed-off-by: Rajendra Nayak <rnayak@ti.com>
This commit is contained in:
R Sricharan 2013-02-07 13:25:39 +05:30 committed by Rajendra Nayak
parent a3a9384a11
commit f18153f984
2 changed files with 3 additions and 2 deletions

View File

@ -132,7 +132,7 @@ config SOC_HAS_OMAP2_SDRC
config SOC_HAS_REALTIME_COUNTER
bool "Real time free running counter"
depends on SOC_OMAP5
depends on SOC_OMAP5 || SOC_DRA7XX
default y
comment "OMAP Core Type"

View File

@ -594,7 +594,8 @@ OMAP_SYS_GP_TIMER_INIT(3, 2, "timer_sys_ck", NULL,
1, "timer_sys_ck", "ti,timer-alwon");
#endif
#if defined(CONFIG_ARCH_OMAP4) || defined(CONFIG_SOC_OMAP5)
#if defined(CONFIG_ARCH_OMAP4) || defined(CONFIG_SOC_OMAP5) || \
defined(CONFIG_SOC_DRA7XX)
static OMAP_SYS_32K_TIMER_INIT(4, 1, "timer_32k_ck", "ti,timer-alwon",
2, "sys_clkin_ck", NULL);