mirror of
https://github.com/torvalds/linux.git
synced 2024-11-24 05:02:12 +00:00
build algorithms into the mac80211 module
The old infrastructure was: - the default algorithm is built into mac80211 - other algorithms get into their own modules The implementation of this complicated scheme was horrible (just look at net/mac80211/Makefile), and anyone adding a new algorithm would most likely not get it right at his first attempt. This patch therefore builds all enabled algorithms into the mac80211 module. The user interface for the rate control algorithms changes as follows: - first the user can choose which algorithms to enable (currently only MAC80211_RC_PID is available) - if more than one algorithm is enabled (currently not possible since only one algorithm is present) the user then chooses the default one Note: - MAC80211_RC_PID is always enables for CONFIG_EMBEDDED=n Technical changes: - all selected algorithms get into the mac80211 module - net/mac80211/Makefile can now become much less complicated - support for rc80211_pid_algo.c being modular is no longer required - this includes unexporting mesh_plink_broken Signed-off-by: Adrian Bunk <bunk@kernel.org> Signed-off-by: John W. Linville <linville@tuxdriver.com>
This commit is contained in:
parent
bf998f6864
commit
e5f5e7339c
@ -27,6 +27,14 @@ comment "QoS/HT support needs CONFIG_NETDEVICES_MULTIQUEUE"
|
||||
menu "Rate control algorithm selection"
|
||||
depends on MAC80211 != n
|
||||
|
||||
config MAC80211_RC_PID
|
||||
bool "PID controller based rate control algorithm" if EMBEDDED
|
||||
default y
|
||||
---help---
|
||||
This option enables a TX rate control algorithm for
|
||||
mac80211 that uses a PID controller to select the TX
|
||||
rate.
|
||||
|
||||
choice
|
||||
prompt "Default rate control algorithm"
|
||||
default MAC80211_RC_DEFAULT_PID
|
||||
@ -38,40 +46,19 @@ choice
|
||||
|
||||
config MAC80211_RC_DEFAULT_PID
|
||||
bool "PID controller based rate control algorithm"
|
||||
select MAC80211_RC_PID
|
||||
depends on MAC80211_RC_PID
|
||||
---help---
|
||||
Select the PID controller based rate control as the
|
||||
default rate control algorithm. You should choose
|
||||
this unless you know what you are doing.
|
||||
|
||||
config MAC80211_RC_DEFAULT_NONE
|
||||
bool "No default algorithm"
|
||||
depends on EMBEDDED
|
||||
help
|
||||
Selecting this option will select no default algorithm
|
||||
and allow you to not build any. Do not choose this
|
||||
option unless you know your driver comes with another
|
||||
suitable algorithm.
|
||||
endchoice
|
||||
|
||||
comment "Selecting 'y' for an algorithm will"
|
||||
comment "build the algorithm into mac80211."
|
||||
|
||||
config MAC80211_RC_DEFAULT
|
||||
string
|
||||
default "pid" if MAC80211_RC_DEFAULT_PID
|
||||
default ""
|
||||
|
||||
config MAC80211_RC_PID
|
||||
tristate "PID controller based rate control algorithm"
|
||||
---help---
|
||||
This option enables a TX rate control algorithm for
|
||||
mac80211 that uses a PID controller to select the TX
|
||||
rate.
|
||||
|
||||
Say Y or M unless you're sure you want to use a
|
||||
different rate control algorithm.
|
||||
|
||||
endmenu
|
||||
|
||||
config MAC80211_MESH
|
||||
|
@ -1,13 +1,5 @@
|
||||
obj-$(CONFIG_MAC80211) += mac80211.o
|
||||
|
||||
# objects for PID algorithm
|
||||
rc80211_pid-y := rc80211_pid_algo.o
|
||||
rc80211_pid-$(CONFIG_MAC80211_DEBUGFS) += rc80211_pid_debugfs.o
|
||||
|
||||
# build helper for PID algorithm
|
||||
rc-pid-y := $(rc80211_pid-y)
|
||||
rc-pid-m := rc80211_pid.o
|
||||
|
||||
# mac80211 objects
|
||||
mac80211-y := \
|
||||
main.o \
|
||||
@ -42,10 +34,8 @@ mac80211-$(CONFIG_MAC80211_MESH) += \
|
||||
mesh_plink.o \
|
||||
mesh_hwmp.o
|
||||
|
||||
# objects for PID algorithm
|
||||
rc80211_pid-y := rc80211_pid_algo.o
|
||||
rc80211_pid-$(CONFIG_MAC80211_DEBUGFS) += rc80211_pid_debugfs.o
|
||||
|
||||
# Build rate control algorithm(s)
|
||||
CFLAGS_rc80211_pid_algo.o += -DRC80211_PID_COMPILE
|
||||
mac80211-$(CONFIG_MAC80211_RC_PID) += $(rc-pid-$(CONFIG_MAC80211_RC_PID))
|
||||
|
||||
# Modular rate algorithms are assigned to mac80211-m - make separate modules
|
||||
obj-m += $(mac80211-m)
|
||||
mac80211-$(CONFIG_MAC80211_RC_PID) += $(rc80211_pid-y)
|
||||
|
@ -262,7 +262,6 @@ void mesh_plink_broken(struct sta_info *sta)
|
||||
}
|
||||
rcu_read_unlock();
|
||||
}
|
||||
EXPORT_SYMBOL(mesh_plink_broken);
|
||||
|
||||
/**
|
||||
* mesh_path_flush_by_nexthop - Deletes mesh paths if their next hop matches
|
||||
|
@ -162,9 +162,7 @@ void rate_control_deinitialize(struct ieee80211_local *local);
|
||||
|
||||
|
||||
/* Rate control algorithms */
|
||||
#if defined(RC80211_PID_COMPILE) || \
|
||||
(defined(CONFIG_MAC80211_RC_PID) && \
|
||||
!defined(CONFIG_MAC80211_RC_PID_MODULE))
|
||||
#ifdef CONFIG_MAC80211_RC_PID
|
||||
extern int rc80211_pid_init(void);
|
||||
extern void rc80211_pid_exit(void);
|
||||
#else
|
||||
|
@ -540,11 +540,6 @@ static struct rate_control_ops mac80211_rcpid = {
|
||||
#endif
|
||||
};
|
||||
|
||||
MODULE_DESCRIPTION("PID controller based rate control algorithm");
|
||||
MODULE_AUTHOR("Stefano Brivio");
|
||||
MODULE_AUTHOR("Mattias Nissler");
|
||||
MODULE_LICENSE("GPL");
|
||||
|
||||
int __init rc80211_pid_init(void)
|
||||
{
|
||||
return ieee80211_rate_control_register(&mac80211_rcpid);
|
||||
@ -554,8 +549,3 @@ void rc80211_pid_exit(void)
|
||||
{
|
||||
ieee80211_rate_control_unregister(&mac80211_rcpid);
|
||||
}
|
||||
|
||||
#ifdef CONFIG_MAC80211_RC_PID_MODULE
|
||||
module_init(rc80211_pid_init);
|
||||
module_exit(rc80211_pid_exit);
|
||||
#endif
|
||||
|
Loading…