pwm: stm32: Implement .get_state()
Implement the &pwm_ops->get_state callback so drivers can inherit PWM state set by the bootloader. Signed-off-by: Philipp Zabel <p.zabel@pengutronix.de> [ukl: split off from a patch that also fixes clk enable count in .probe()] Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de> Reviewed-by: Fabrice Gasnier <fabrice.gasnier@foss.st.com> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
This commit is contained in:
parent
41fa8f57c0
commit
e56ec7b752
@ -471,8 +471,50 @@ static int stm32_pwm_apply_locked(struct pwm_chip *chip, struct pwm_device *pwm,
|
||||
return ret;
|
||||
}
|
||||
|
||||
static int stm32_pwm_get_state(struct pwm_chip *chip,
|
||||
struct pwm_device *pwm, struct pwm_state *state)
|
||||
{
|
||||
struct stm32_pwm *priv = to_stm32_pwm_dev(chip);
|
||||
int ch = pwm->hwpwm;
|
||||
unsigned long rate;
|
||||
u32 ccer, psc, arr, ccr;
|
||||
u64 dty, prd;
|
||||
int ret;
|
||||
|
||||
mutex_lock(&priv->lock);
|
||||
|
||||
ret = regmap_read(priv->regmap, TIM_CCER, &ccer);
|
||||
if (ret)
|
||||
goto out;
|
||||
|
||||
state->enabled = ccer & (TIM_CCER_CC1E << (ch * 4));
|
||||
state->polarity = (ccer & (TIM_CCER_CC1P << (ch * 4))) ?
|
||||
PWM_POLARITY_INVERSED : PWM_POLARITY_NORMAL;
|
||||
ret = regmap_read(priv->regmap, TIM_PSC, &psc);
|
||||
if (ret)
|
||||
goto out;
|
||||
ret = regmap_read(priv->regmap, TIM_ARR, &arr);
|
||||
if (ret)
|
||||
goto out;
|
||||
ret = regmap_read(priv->regmap, TIM_CCR1 + 4 * ch, &ccr);
|
||||
if (ret)
|
||||
goto out;
|
||||
|
||||
rate = clk_get_rate(priv->clk);
|
||||
|
||||
prd = (u64)NSEC_PER_SEC * (psc + 1) * (arr + 1);
|
||||
state->period = DIV_ROUND_UP_ULL(prd, rate);
|
||||
dty = (u64)NSEC_PER_SEC * (psc + 1) * ccr;
|
||||
state->duty_cycle = DIV_ROUND_UP_ULL(dty, rate);
|
||||
|
||||
out:
|
||||
mutex_unlock(&priv->lock);
|
||||
return ret;
|
||||
}
|
||||
|
||||
static const struct pwm_ops stm32pwm_ops = {
|
||||
.apply = stm32_pwm_apply_locked,
|
||||
.get_state = stm32_pwm_get_state,
|
||||
.capture = IS_ENABLED(CONFIG_DMA_ENGINE) ? stm32_pwm_capture : NULL,
|
||||
};
|
||||
|
||||
|
Loading…