hwmon: (drivetemp) Add usage not describing impact on drive spin-down
On some drives, reading the drive temperature resets the drive's spin-down timer. If the drive temperature is read too often, affected drives will never spin down. Add this information as usage note to the driver documentation. Reported-by: Peter Sulyok <peter@sulyok.net> Cc: Peter Sulyok <peter@sulyok.net> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
parent
787c095eda
commit
e403583909
@ -30,6 +30,24 @@ Transport is not supported, the driver uses SMART attributes to read
|
|||||||
the drive temperature.
|
the drive temperature.
|
||||||
|
|
||||||
|
|
||||||
|
Usage Note
|
||||||
|
----------
|
||||||
|
|
||||||
|
Reading the drive temperature may reset the spin down timer on some drives.
|
||||||
|
This has been observed with WD120EFAX drives, but may be seen with other
|
||||||
|
drives as well. The same behavior is observed if the 'hdtemp' or 'smartd'
|
||||||
|
tools are used to access the drive.
|
||||||
|
With the WD120EFAX drive, reading the drive temperature using the drivetemp
|
||||||
|
driver is still possible _after_ it transitioned to standby mode, and
|
||||||
|
reading the drive temperature in this mode will not cause the drive to
|
||||||
|
change its mode (meaning the drive will not spin up). It is unknown if other
|
||||||
|
drives experience similar behavior.
|
||||||
|
|
||||||
|
A known workaround for WD120EFAX drives is to read the drive temperature at
|
||||||
|
intervals larger than twice the spin-down time. Otherwise affected drives
|
||||||
|
will never spin down.
|
||||||
|
|
||||||
|
|
||||||