[PATCH] powerpc: Fix windfarm_pm112 not starting all control loops
This adds a couple of printk's to windfarm_pm112 to display which control loops are actually starting and fixes a bug where it would not start all loops. Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org> Signed-off-by: Paul Mackerras <paulus@samba.org>
This commit is contained in:
parent
b55fafc5a8
commit
e2a002b9a7
@ -358,6 +358,7 @@ static void backside_fan_tick(void)
|
|||||||
return;
|
return;
|
||||||
if (!backside_tick) {
|
if (!backside_tick) {
|
||||||
/* first time; initialize things */
|
/* first time; initialize things */
|
||||||
|
printk(KERN_INFO "windfarm: Backside control loop started.\n");
|
||||||
backside_param.min = backside_fan->ops->get_min(backside_fan);
|
backside_param.min = backside_fan->ops->get_min(backside_fan);
|
||||||
backside_param.max = backside_fan->ops->get_max(backside_fan);
|
backside_param.max = backside_fan->ops->get_max(backside_fan);
|
||||||
wf_pid_init(&backside_pid, &backside_param);
|
wf_pid_init(&backside_pid, &backside_param);
|
||||||
@ -407,6 +408,7 @@ static void drive_bay_fan_tick(void)
|
|||||||
return;
|
return;
|
||||||
if (!drive_bay_tick) {
|
if (!drive_bay_tick) {
|
||||||
/* first time; initialize things */
|
/* first time; initialize things */
|
||||||
|
printk(KERN_INFO "windfarm: Drive bay control loop started.\n");
|
||||||
drive_bay_prm.min = drive_bay_fan->ops->get_min(drive_bay_fan);
|
drive_bay_prm.min = drive_bay_fan->ops->get_min(drive_bay_fan);
|
||||||
drive_bay_prm.max = drive_bay_fan->ops->get_max(drive_bay_fan);
|
drive_bay_prm.max = drive_bay_fan->ops->get_max(drive_bay_fan);
|
||||||
wf_pid_init(&drive_bay_pid, &drive_bay_prm);
|
wf_pid_init(&drive_bay_pid, &drive_bay_prm);
|
||||||
@ -458,6 +460,7 @@ static void slots_fan_tick(void)
|
|||||||
return;
|
return;
|
||||||
if (!slots_started) {
|
if (!slots_started) {
|
||||||
/* first time; initialize things */
|
/* first time; initialize things */
|
||||||
|
printk(KERN_INFO "windfarm: Slots control loop started.\n");
|
||||||
wf_pid_init(&slots_pid, &slots_param);
|
wf_pid_init(&slots_pid, &slots_param);
|
||||||
slots_started = 1;
|
slots_started = 1;
|
||||||
}
|
}
|
||||||
@ -504,6 +507,7 @@ static void pm112_tick(void)
|
|||||||
|
|
||||||
if (!started) {
|
if (!started) {
|
||||||
started = 1;
|
started = 1;
|
||||||
|
printk(KERN_INFO "windfarm: CPUs control loops started.\n");
|
||||||
for (i = 0; i < nr_cores; ++i) {
|
for (i = 0; i < nr_cores; ++i) {
|
||||||
if (create_cpu_loop(i) < 0) {
|
if (create_cpu_loop(i) < 0) {
|
||||||
failure_state = FAILURE_PERM;
|
failure_state = FAILURE_PERM;
|
||||||
@ -594,8 +598,6 @@ static void pm112_new_sensor(struct wf_sensor *sr)
|
|||||||
{
|
{
|
||||||
unsigned int i;
|
unsigned int i;
|
||||||
|
|
||||||
if (have_all_sensors)
|
|
||||||
return;
|
|
||||||
if (!strncmp(sr->name, "cpu-temp-", 9)) {
|
if (!strncmp(sr->name, "cpu-temp-", 9)) {
|
||||||
i = sr->name[9] - '0';
|
i = sr->name[9] - '0';
|
||||||
if (sr->name[10] == 0 && i < NR_CORES &&
|
if (sr->name[10] == 0 && i < NR_CORES &&
|
||||||
|
Loading…
Reference in New Issue