charger-manager: Poll battery health in normal state
Charger-Manager needs to check battery health in normal state as well as suspend-to-RAM state. When the battery is fully charged, Charger-Manager needs to determine when the chargers restart charging. This patch allows Charger-Manager to monitor battery health in normal state and handle operation for chargers after battery is fully charged. Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com> Signed-off-by: Donggeun Kim <dg77.kim@samsung.com> Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com> Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
This commit is contained in:
parent
34298d40e5
commit
d829dc75ba
@ -44,6 +44,12 @@ Charger Manager supports the following:
|
||||
Normally, the platform will need to resume and suspend some devices
|
||||
that are used by Charger Manager.
|
||||
|
||||
* Support for premature full-battery event handling
|
||||
If the battery voltage drops by "fullbatt_vchkdrop_uV" after
|
||||
"fullbatt_vchkdrop_ms" from the full-battery event, the framework
|
||||
restarts charging. This check is also performed while suspended by
|
||||
setting wakeup time accordingly and using suspend_again.
|
||||
|
||||
2. Global Charger-Manager Data related with suspend_again
|
||||
========================================================
|
||||
In order to setup Charger Manager with suspend-again feature
|
||||
@ -55,7 +61,7 @@ if there are multiple batteries. If there are multiple batteries, the
|
||||
multiple instances of Charger Manager share the same charger_global_desc
|
||||
and it will manage in-suspend monitoring for all instances of Charger Manager.
|
||||
|
||||
The user needs to provide all the two entries properly in order to activate
|
||||
The user needs to provide all the three entries properly in order to activate
|
||||
in-suspend monitoring:
|
||||
|
||||
struct charger_global_desc {
|
||||
@ -74,6 +80,11 @@ bool (*rtc_only_wakeup)(void);
|
||||
same struct. If there is any other wakeup source triggered the
|
||||
wakeup, it should return false. If the "rtc" is the only wakeup
|
||||
reason, it should return true.
|
||||
|
||||
bool assume_timer_stops_in_suspend;
|
||||
: if true, Charger Manager assumes that
|
||||
the timer (CM uses jiffies as timer) stops during suspend. Then, CM
|
||||
assumes that the suspend-duration is same as the alarm length.
|
||||
};
|
||||
|
||||
3. How to setup suspend_again
|
||||
@ -111,6 +122,16 @@ enum polling_modes polling_mode;
|
||||
CM_POLL_CHARGING_ONLY: poll this battery if and only if the
|
||||
battery is being charged.
|
||||
|
||||
unsigned int fullbatt_vchkdrop_ms;
|
||||
unsigned int fullbatt_vchkdrop_uV;
|
||||
: If both have non-zero values, Charger Manager will check the
|
||||
battery voltage drop fullbatt_vchkdrop_ms after the battery is fully
|
||||
charged. If the voltage drop is over fullbatt_vchkdrop_uV, Charger
|
||||
Manager will try to recharge the battery by disabling and enabling
|
||||
chargers. Recharge with voltage drop condition only (without delay
|
||||
condition) is needed to be implemented with hardware interrupts from
|
||||
fuel gauges or charger devices/chips.
|
||||
|
||||
unsigned int fullbatt_uV;
|
||||
: If specified with a non-zero value, Charger Manager assumes
|
||||
that the battery is full (capacity = 100) if the battery is not being
|
||||
@ -122,6 +143,8 @@ unsigned int polling_interval_ms;
|
||||
this battery every polling_interval_ms or more frequently.
|
||||
|
||||
enum data_source battery_present;
|
||||
: CM_BATTERY_PRESENT: assume that the battery exists.
|
||||
CM_NO_BATTERY: assume that the battery does not exists.
|
||||
CM_FUEL_GAUGE: get battery presence information from fuel gauge.
|
||||
CM_CHARGER_STAT: get battery presence from chargers.
|
||||
|
||||
|
@ -57,6 +57,12 @@ static bool cm_suspended;
|
||||
static bool cm_rtc_set;
|
||||
static unsigned long cm_suspend_duration_ms;
|
||||
|
||||
/* About normal (not suspended) monitoring */
|
||||
static unsigned long polling_jiffy = ULONG_MAX; /* ULONG_MAX: no polling */
|
||||
static unsigned long next_polling; /* Next appointed polling time */
|
||||
static struct workqueue_struct *cm_wq; /* init at driver add */
|
||||
static struct delayed_work cm_monitor_work; /* init at driver add */
|
||||
|
||||
/* Global charger-manager description */
|
||||
static struct charger_global_desc *g_desc; /* init with setup_charger_manager */
|
||||
|
||||
@ -71,6 +77,11 @@ static bool is_batt_present(struct charger_manager *cm)
|
||||
int i, ret;
|
||||
|
||||
switch (cm->desc->battery_present) {
|
||||
case CM_BATTERY_PRESENT:
|
||||
present = true;
|
||||
break;
|
||||
case CM_NO_BATTERY:
|
||||
break;
|
||||
case CM_FUEL_GAUGE:
|
||||
ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
|
||||
POWER_SUPPLY_PROP_PRESENT, &val);
|
||||
@ -278,6 +289,26 @@ static int try_charger_enable(struct charger_manager *cm, bool enable)
|
||||
return err;
|
||||
}
|
||||
|
||||
/**
|
||||
* try_charger_restart - Restart charging.
|
||||
* @cm: the Charger Manager representing the battery.
|
||||
*
|
||||
* Restart charging by turning off and on the charger.
|
||||
*/
|
||||
static int try_charger_restart(struct charger_manager *cm)
|
||||
{
|
||||
int err;
|
||||
|
||||
if (cm->emergency_stop)
|
||||
return -EAGAIN;
|
||||
|
||||
err = try_charger_enable(cm, false);
|
||||
if (err)
|
||||
return err;
|
||||
|
||||
return try_charger_enable(cm, true);
|
||||
}
|
||||
|
||||
/**
|
||||
* uevent_notify - Let users know something has changed.
|
||||
* @cm: the Charger Manager representing the battery.
|
||||
@ -333,6 +364,46 @@ static void uevent_notify(struct charger_manager *cm, const char *event)
|
||||
dev_info(cm->dev, event);
|
||||
}
|
||||
|
||||
/**
|
||||
* fullbatt_vchk - Check voltage drop some times after "FULL" event.
|
||||
* @work: the work_struct appointing the function
|
||||
*
|
||||
* If a user has designated "fullbatt_vchkdrop_ms/uV" values with
|
||||
* charger_desc, Charger Manager checks voltage drop after the battery
|
||||
* "FULL" event. It checks whether the voltage has dropped more than
|
||||
* fullbatt_vchkdrop_uV by calling this function after fullbatt_vchkrop_ms.
|
||||
*/
|
||||
static void fullbatt_vchk(struct work_struct *work)
|
||||
{
|
||||
struct delayed_work *dwork = to_delayed_work(work);
|
||||
struct charger_manager *cm = container_of(dwork,
|
||||
struct charger_manager, fullbatt_vchk_work);
|
||||
struct charger_desc *desc = cm->desc;
|
||||
int batt_uV, err, diff;
|
||||
|
||||
/* remove the appointment for fullbatt_vchk */
|
||||
cm->fullbatt_vchk_jiffies_at = 0;
|
||||
|
||||
if (!desc->fullbatt_vchkdrop_uV || !desc->fullbatt_vchkdrop_ms)
|
||||
return;
|
||||
|
||||
err = get_batt_uV(cm, &batt_uV);
|
||||
if (err) {
|
||||
dev_err(cm->dev, "%s: get_batt_uV error(%d).\n", __func__, err);
|
||||
return;
|
||||
}
|
||||
|
||||
diff = cm->fullbatt_vchk_uV;
|
||||
diff -= batt_uV;
|
||||
|
||||
dev_dbg(cm->dev, "VBATT dropped %duV after full-batt.\n", diff);
|
||||
|
||||
if (diff > desc->fullbatt_vchkdrop_uV) {
|
||||
try_charger_restart(cm);
|
||||
uevent_notify(cm, "Recharge");
|
||||
}
|
||||
}
|
||||
|
||||
/**
|
||||
* _cm_monitor - Monitor the temperature and return true for exceptions.
|
||||
* @cm: the Charger Manager representing the battery.
|
||||
@ -392,6 +463,68 @@ static bool cm_monitor(void)
|
||||
return stop;
|
||||
}
|
||||
|
||||
/**
|
||||
* _setup_polling - Setup the next instance of polling.
|
||||
* @work: work_struct of the function _setup_polling.
|
||||
*/
|
||||
static void _setup_polling(struct work_struct *work)
|
||||
{
|
||||
unsigned long min = ULONG_MAX;
|
||||
struct charger_manager *cm;
|
||||
bool keep_polling = false;
|
||||
unsigned long _next_polling;
|
||||
|
||||
mutex_lock(&cm_list_mtx);
|
||||
|
||||
list_for_each_entry(cm, &cm_list, entry) {
|
||||
if (is_polling_required(cm) && cm->desc->polling_interval_ms) {
|
||||
keep_polling = true;
|
||||
|
||||
if (min > cm->desc->polling_interval_ms)
|
||||
min = cm->desc->polling_interval_ms;
|
||||
}
|
||||
}
|
||||
|
||||
polling_jiffy = msecs_to_jiffies(min);
|
||||
if (polling_jiffy <= CM_JIFFIES_SMALL)
|
||||
polling_jiffy = CM_JIFFIES_SMALL + 1;
|
||||
|
||||
if (!keep_polling)
|
||||
polling_jiffy = ULONG_MAX;
|
||||
if (polling_jiffy == ULONG_MAX)
|
||||
goto out;
|
||||
|
||||
WARN(cm_wq == NULL, "charger-manager: workqueue not initialized"
|
||||
". try it later. %s\n", __func__);
|
||||
|
||||
_next_polling = jiffies + polling_jiffy;
|
||||
|
||||
if (!delayed_work_pending(&cm_monitor_work) ||
|
||||
(delayed_work_pending(&cm_monitor_work) &&
|
||||
time_after(next_polling, _next_polling))) {
|
||||
cancel_delayed_work_sync(&cm_monitor_work);
|
||||
next_polling = jiffies + polling_jiffy;
|
||||
queue_delayed_work(cm_wq, &cm_monitor_work, polling_jiffy);
|
||||
}
|
||||
|
||||
out:
|
||||
mutex_unlock(&cm_list_mtx);
|
||||
}
|
||||
static DECLARE_WORK(setup_polling, _setup_polling);
|
||||
|
||||
/**
|
||||
* cm_monitor_poller - The Monitor / Poller.
|
||||
* @work: work_struct of the function cm_monitor_poller
|
||||
*
|
||||
* During non-suspended state, cm_monitor_poller is used to poll and monitor
|
||||
* the batteries.
|
||||
*/
|
||||
static void cm_monitor_poller(struct work_struct *work)
|
||||
{
|
||||
cm_monitor();
|
||||
schedule_work(&setup_polling);
|
||||
}
|
||||
|
||||
static int charger_get_property(struct power_supply *psy,
|
||||
enum power_supply_property psp,
|
||||
union power_supply_propval *val)
|
||||
@ -613,6 +746,21 @@ static bool cm_setup_timer(void)
|
||||
mutex_lock(&cm_list_mtx);
|
||||
|
||||
list_for_each_entry(cm, &cm_list, entry) {
|
||||
unsigned int fbchk_ms = 0;
|
||||
|
||||
/* fullbatt_vchk is required. setup timer for that */
|
||||
if (cm->fullbatt_vchk_jiffies_at) {
|
||||
fbchk_ms = jiffies_to_msecs(cm->fullbatt_vchk_jiffies_at
|
||||
- jiffies);
|
||||
if (time_is_before_eq_jiffies(
|
||||
cm->fullbatt_vchk_jiffies_at) ||
|
||||
msecs_to_jiffies(fbchk_ms) < CM_JIFFIES_SMALL) {
|
||||
fullbatt_vchk(&cm->fullbatt_vchk_work.work);
|
||||
fbchk_ms = 0;
|
||||
}
|
||||
}
|
||||
CM_MIN_VALID(wakeup_ms, fbchk_ms);
|
||||
|
||||
/* Skip if polling is not required for this CM */
|
||||
if (!is_polling_required(cm) && !cm->emergency_stop)
|
||||
continue;
|
||||
@ -672,6 +820,23 @@ static bool cm_setup_timer(void)
|
||||
return false;
|
||||
}
|
||||
|
||||
static void _cm_fbchk_in_suspend(struct charger_manager *cm)
|
||||
{
|
||||
unsigned long jiffy_now = jiffies;
|
||||
|
||||
if (!cm->fullbatt_vchk_jiffies_at)
|
||||
return;
|
||||
|
||||
if (g_desc && g_desc->assume_timer_stops_in_suspend)
|
||||
jiffy_now += msecs_to_jiffies(cm_suspend_duration_ms);
|
||||
|
||||
/* Execute now if it's going to be executed not too long after */
|
||||
jiffy_now += CM_JIFFIES_SMALL;
|
||||
|
||||
if (time_after_eq(jiffy_now, cm->fullbatt_vchk_jiffies_at))
|
||||
fullbatt_vchk(&cm->fullbatt_vchk_work.work);
|
||||
}
|
||||
|
||||
/**
|
||||
* cm_suspend_again - Determine whether suspend again or not
|
||||
*
|
||||
@ -693,6 +858,8 @@ bool cm_suspend_again(void)
|
||||
ret = true;
|
||||
mutex_lock(&cm_list_mtx);
|
||||
list_for_each_entry(cm, &cm_list, entry) {
|
||||
_cm_fbchk_in_suspend(cm);
|
||||
|
||||
if (cm->status_save_ext_pwr_inserted != is_ext_pwr_online(cm) ||
|
||||
cm->status_save_batt != is_batt_present(cm)) {
|
||||
ret = false;
|
||||
@ -796,6 +963,21 @@ static int charger_manager_probe(struct platform_device *pdev)
|
||||
memcpy(cm->desc, desc, sizeof(struct charger_desc));
|
||||
cm->last_temp_mC = INT_MIN; /* denotes "unmeasured, yet" */
|
||||
|
||||
/*
|
||||
* The following two do not need to be errors.
|
||||
* Users may intentionally ignore those two features.
|
||||
*/
|
||||
if (desc->fullbatt_uV == 0) {
|
||||
dev_info(&pdev->dev, "Ignoring full-battery voltage threshold"
|
||||
" as it is not supplied.");
|
||||
}
|
||||
if (!desc->fullbatt_vchkdrop_ms || !desc->fullbatt_vchkdrop_uV) {
|
||||
dev_info(&pdev->dev, "Disabling full-battery voltage drop "
|
||||
"checking mechanism as it is not supplied.");
|
||||
desc->fullbatt_vchkdrop_ms = 0;
|
||||
desc->fullbatt_vchkdrop_uV = 0;
|
||||
}
|
||||
|
||||
if (!desc->charger_regulators || desc->num_charger_regulators < 1) {
|
||||
ret = -EINVAL;
|
||||
dev_err(&pdev->dev, "charger_regulators undefined.\n");
|
||||
@ -903,6 +1085,8 @@ static int charger_manager_probe(struct platform_device *pdev)
|
||||
cm->charger_psy.num_properties++;
|
||||
}
|
||||
|
||||
INIT_DELAYED_WORK(&cm->fullbatt_vchk_work, fullbatt_vchk);
|
||||
|
||||
ret = power_supply_register(NULL, &cm->charger_psy);
|
||||
if (ret) {
|
||||
dev_err(&pdev->dev, "Cannot register charger-manager with"
|
||||
@ -928,6 +1112,8 @@ static int charger_manager_probe(struct platform_device *pdev)
|
||||
list_add(&cm->entry, &cm_list);
|
||||
mutex_unlock(&cm_list_mtx);
|
||||
|
||||
schedule_work(&setup_polling);
|
||||
|
||||
return 0;
|
||||
|
||||
err_chg_enable:
|
||||
@ -958,9 +1144,17 @@ static int __devexit charger_manager_remove(struct platform_device *pdev)
|
||||
list_del(&cm->entry);
|
||||
mutex_unlock(&cm_list_mtx);
|
||||
|
||||
if (work_pending(&setup_polling))
|
||||
cancel_work_sync(&setup_polling);
|
||||
if (delayed_work_pending(&cm_monitor_work))
|
||||
cancel_delayed_work_sync(&cm_monitor_work);
|
||||
|
||||
regulator_bulk_free(desc->num_charger_regulators,
|
||||
desc->charger_regulators);
|
||||
power_supply_unregister(&cm->charger_psy);
|
||||
|
||||
try_charger_enable(cm, false);
|
||||
|
||||
kfree(cm->charger_psy.properties);
|
||||
kfree(cm->charger_stat);
|
||||
kfree(cm->desc);
|
||||
@ -1000,6 +1194,8 @@ static int cm_suspend_prepare(struct device *dev)
|
||||
cm_suspended = true;
|
||||
}
|
||||
|
||||
if (delayed_work_pending(&cm->fullbatt_vchk_work))
|
||||
cancel_delayed_work(&cm->fullbatt_vchk_work);
|
||||
cm->status_save_ext_pwr_inserted = is_ext_pwr_online(cm);
|
||||
cm->status_save_batt = is_batt_present(cm);
|
||||
|
||||
@ -1027,6 +1223,33 @@ static void cm_suspend_complete(struct device *dev)
|
||||
cm_rtc_set = false;
|
||||
}
|
||||
|
||||
/* Re-enqueue delayed work (fullbatt_vchk_work) */
|
||||
if (cm->fullbatt_vchk_jiffies_at) {
|
||||
unsigned long delay = 0;
|
||||
unsigned long now = jiffies + CM_JIFFIES_SMALL;
|
||||
|
||||
if (time_after_eq(now, cm->fullbatt_vchk_jiffies_at)) {
|
||||
delay = (unsigned long)((long)now
|
||||
- (long)(cm->fullbatt_vchk_jiffies_at));
|
||||
delay = jiffies_to_msecs(delay);
|
||||
} else {
|
||||
delay = 0;
|
||||
}
|
||||
|
||||
/*
|
||||
* Account for cm_suspend_duration_ms if
|
||||
* assume_timer_stops_in_suspend is active
|
||||
*/
|
||||
if (g_desc && g_desc->assume_timer_stops_in_suspend) {
|
||||
if (delay > cm_suspend_duration_ms)
|
||||
delay -= cm_suspend_duration_ms;
|
||||
else
|
||||
delay = 0;
|
||||
}
|
||||
|
||||
queue_delayed_work(cm_wq, &cm->fullbatt_vchk_work,
|
||||
msecs_to_jiffies(delay));
|
||||
}
|
||||
uevent_notify(cm, NULL);
|
||||
}
|
||||
|
||||
@ -1048,12 +1271,18 @@ static struct platform_driver charger_manager_driver = {
|
||||
|
||||
static int __init charger_manager_init(void)
|
||||
{
|
||||
cm_wq = create_freezable_workqueue("charger_manager");
|
||||
INIT_DELAYED_WORK(&cm_monitor_work, cm_monitor_poller);
|
||||
|
||||
return platform_driver_register(&charger_manager_driver);
|
||||
}
|
||||
late_initcall(charger_manager_init);
|
||||
|
||||
static void __exit charger_manager_cleanup(void)
|
||||
{
|
||||
destroy_workqueue(cm_wq);
|
||||
cm_wq = NULL;
|
||||
|
||||
platform_driver_unregister(&charger_manager_driver);
|
||||
}
|
||||
module_exit(charger_manager_cleanup);
|
||||
|
@ -18,6 +18,8 @@
|
||||
#include <linux/power_supply.h>
|
||||
|
||||
enum data_source {
|
||||
CM_BATTERY_PRESENT,
|
||||
CM_NO_BATTERY,
|
||||
CM_FUEL_GAUGE,
|
||||
CM_CHARGER_STAT,
|
||||
};
|
||||
@ -38,11 +40,18 @@ enum polling_modes {
|
||||
* rtc_only_wakeup() returning false.
|
||||
* If the RTC given to CM is the only wakeup reason,
|
||||
* rtc_only_wakeup should return true.
|
||||
* @assume_timer_stops_in_suspend:
|
||||
* Assume that the jiffy timer stops in suspend-to-RAM.
|
||||
* When enabled, CM does not rely on jiffies value in
|
||||
* suspend_again and assumes that jiffies value does not
|
||||
* change during suspend.
|
||||
*/
|
||||
struct charger_global_desc {
|
||||
char *rtc_name;
|
||||
|
||||
bool (*rtc_only_wakeup)(void);
|
||||
|
||||
bool assume_timer_stops_in_suspend;
|
||||
};
|
||||
|
||||
/**
|
||||
@ -50,6 +59,11 @@ struct charger_global_desc {
|
||||
* @psy_name: the name of power-supply-class for charger manager
|
||||
* @polling_mode:
|
||||
* Determine which polling mode will be used
|
||||
* @fullbatt_vchkdrop_ms:
|
||||
* @fullbatt_vchkdrop_uV:
|
||||
* Check voltage drop after the battery is fully charged.
|
||||
* If it has dropped more than fullbatt_vchkdrop_uV after
|
||||
* fullbatt_vchkdrop_ms, CM will restart charging.
|
||||
* @fullbatt_uV: voltage in microvolt
|
||||
* If it is not being charged and VBATT >= fullbatt_uV,
|
||||
* it is assumed to be full.
|
||||
@ -76,6 +90,8 @@ struct charger_desc {
|
||||
enum polling_modes polling_mode;
|
||||
unsigned int polling_interval_ms;
|
||||
|
||||
unsigned int fullbatt_vchkdrop_ms;
|
||||
unsigned int fullbatt_vchkdrop_uV;
|
||||
unsigned int fullbatt_uV;
|
||||
|
||||
enum data_source battery_present;
|
||||
@ -101,6 +117,11 @@ struct charger_desc {
|
||||
* @fuel_gauge: power_supply for fuel gauge
|
||||
* @charger_stat: array of power_supply for chargers
|
||||
* @charger_enabled: the state of charger
|
||||
* @fullbatt_vchk_jiffies_at:
|
||||
* jiffies at the time full battery check will occur.
|
||||
* @fullbatt_vchk_uV: voltage in microvolt
|
||||
* criteria for full battery
|
||||
* @fullbatt_vchk_work: work queue for full battery check
|
||||
* @emergency_stop:
|
||||
* When setting true, stop charging
|
||||
* @last_temp_mC: the measured temperature in milli-Celsius
|
||||
@ -121,6 +142,10 @@ struct charger_manager {
|
||||
|
||||
bool charger_enabled;
|
||||
|
||||
unsigned long fullbatt_vchk_jiffies_at;
|
||||
unsigned int fullbatt_vchk_uV;
|
||||
struct delayed_work fullbatt_vchk_work;
|
||||
|
||||
int emergency_stop;
|
||||
int last_temp_mC;
|
||||
|
||||
|
Loading…