drm/i915: fix PCH PLL assertion check for 3 pipes
Add a couple of checks now that we're using the 3rd transcoder: 1) make sure the transcoder PLL enable bit is set for the transcoder in question 2) when checking actual PLL enable, use the selected PLL number rather than the transcoder number (they could be different now) Signed-off-by: Jesse Barnes <jbarnes@virtuousgeek.org> Tested-By: Eugeni Dodonov <eugeni.dodonov@intel.com> Reviewed-By: Eugeni Dodonov <eugeni.dodonov@intel.com> Signed-off-by: Keith Packard <keithp@keithp.com>
This commit is contained in:
parent
75770564c9
commit
d3ccbe8670
@ -803,6 +803,19 @@ static void assert_pch_pll(struct drm_i915_private *dev_priv,
|
||||
u32 val;
|
||||
bool cur_state;
|
||||
|
||||
if (HAS_PCH_CPT(dev_priv->dev)) {
|
||||
u32 pch_dpll;
|
||||
|
||||
pch_dpll = I915_READ(PCH_DPLL_SEL);
|
||||
|
||||
/* Make sure the selected PLL is enabled to the transcoder */
|
||||
WARN(!((pch_dpll >> (4 * pipe)) & 8),
|
||||
"transcoder %d PLL not enabled\n", pipe);
|
||||
|
||||
/* Convert the transcoder pipe number to a pll pipe number */
|
||||
pipe = (pch_dpll >> (4 * pipe)) & 1;
|
||||
}
|
||||
|
||||
reg = PCH_DPLL(pipe);
|
||||
val = I915_READ(reg);
|
||||
cur_state = !!(val & DPLL_VCO_ENABLE);
|
||||
|
Loading…