iio: hid-sensor: fix return of -EINVAL on invalid values in ret or value

Ensure that when an invalid value in ret or value is found -EINVAL
is returned. A previous commit broke the way the return error is
being returned and instead caused the return code in ret to be
re-assigned rather than be returned.

Fixes: 5d9854eaea ("iio: hid-sensor: Store restore poll and hysteresis on S3")
Signed-off-by: Colin Ian King <colin.king@canonical.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This commit is contained in:
Colin Ian King 2017-04-19 15:35:48 +01:00 committed by Jonathan Cameron
parent c36662193b
commit c894acc7bf

View File

@ -230,7 +230,7 @@ int hid_sensor_write_samp_freq_value(struct hid_sensor_common *st,
ret = sensor_hub_set_feature(st->hsdev, st->poll.report_id,
st->poll.index, sizeof(value), &value);
if (ret < 0 || value < 0)
ret = -EINVAL;
return -EINVAL;
ret = sensor_hub_get_feature(st->hsdev,
st->poll.report_id,
@ -283,7 +283,7 @@ int hid_sensor_write_raw_hyst_value(struct hid_sensor_common *st,
st->sensitivity.index, sizeof(value),
&value);
if (ret < 0 || value < 0)
ret = -EINVAL;
return -EINVAL;
ret = sensor_hub_get_feature(st->hsdev,
st->sensitivity.report_id,