mirror of
https://github.com/torvalds/linux.git
synced 2024-11-24 05:02:12 +00:00
HID: hid-input: occasionally report stylus battery even if not changed
There are styluses that only report their battery status when they are touching the touchscreen; additionally we currently suppress battery reports if capacity has not changed. To help userspace recognize how long ago the device reported battery status, let's send the change event through if either capacity has changed, or at least 30 seconds have passed since last report we've let through. Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This commit is contained in:
parent
bf36c6b946
commit
c6838eeef2
@ -534,9 +534,12 @@ static void hidinput_update_battery(struct hid_device *dev, int value)
|
||||
capacity = hidinput_scale_battery_capacity(dev, value);
|
||||
|
||||
if (dev->battery_status != HID_BATTERY_REPORTED ||
|
||||
capacity != dev->battery_capacity) {
|
||||
capacity != dev->battery_capacity ||
|
||||
ktime_after(ktime_get_coarse(), dev->battery_ratelimit_time)) {
|
||||
dev->battery_capacity = capacity;
|
||||
dev->battery_status = HID_BATTERY_REPORTED;
|
||||
dev->battery_ratelimit_time =
|
||||
ktime_add_ms(ktime_get_coarse(), 30 * 1000);
|
||||
power_supply_changed(dev->battery);
|
||||
}
|
||||
}
|
||||
|
@ -585,6 +585,7 @@ struct hid_device { /* device report descriptor */
|
||||
__s32 battery_report_id;
|
||||
enum hid_battery_status battery_status;
|
||||
bool battery_avoid_query;
|
||||
ktime_t battery_ratelimit_time;
|
||||
#endif
|
||||
|
||||
unsigned long status; /* see STAT flags above */
|
||||
|
Loading…