mirror of
https://github.com/torvalds/linux.git
synced 2024-11-25 05:32:00 +00:00
i2c-pnx: fix setting start/stop condition
The start/stop condtions are set in different places repetedly in the i2c-pnx driver. Beside in i2c_pnx_start and i2c_pnx_stop the start/stop bit are also set during the transfer of a i2c message in the master_xmit/rcv calls. This is wrong since we can't set the start/stop condition during the transaction of a single message any way. As a matter of fact, the driver will sometimes set both the start and the stop bits at one time. This can be easily reproduced by sending a simple read request like e.g struct i2c_msg msgs[] = { { addr, 0, 1, buf }, { addr, I2C_M_RD, offset, buf } }; While processing the first message the i2c_pnx_master_xmit will set both the start_bit and the stop_bit, which will eventually confuse the slave. Fixed by remove setting start/stop condition from the transmit routines. Signed-off-by: Luotao Fu <l.fu@pengutronix.de> Signed-off-by: Ben Dooks <ben-linux@fluff.org>
This commit is contained in:
parent
96eb7164e3
commit
ad0194e8d6
@ -172,12 +172,6 @@ static int i2c_pnx_master_xmit(struct i2c_pnx_algo_data *alg_data)
|
||||
/* We still have something to talk about... */
|
||||
val = *alg_data->mif.buf++;
|
||||
|
||||
if (alg_data->mif.len == 1) {
|
||||
val |= stop_bit;
|
||||
if (!alg_data->last)
|
||||
val |= start_bit;
|
||||
}
|
||||
|
||||
alg_data->mif.len--;
|
||||
iowrite32(val, I2C_REG_TX(alg_data));
|
||||
|
||||
@ -251,11 +245,6 @@ static int i2c_pnx_master_rcv(struct i2c_pnx_algo_data *alg_data)
|
||||
__func__);
|
||||
|
||||
if (alg_data->mif.len == 1) {
|
||||
/* Last byte, do not acknowledge next rcv. */
|
||||
val |= stop_bit;
|
||||
if (!alg_data->last)
|
||||
val |= start_bit;
|
||||
|
||||
/*
|
||||
* Enable interrupt RFDAIE (data in Rx fifo),
|
||||
* and disable DRMIE (need data for Tx)
|
||||
|