Bluetooth: Fix updating settings when there are no HCI commands to send

It is possible that the Set Connectable management command doesn't cause
any HCI commands to send (such as when BR/EDR is disabled). We can't
just send a response to user space in this case but must also update the
necessary device flags and settings. This patch fixes the issue by using
the recently introduced set_connectable_update_settings function.

Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This commit is contained in:
Johan Hedberg 2013-10-19 23:38:19 +03:00 committed by Marcel Holtmann
parent e8ba3a1f08
commit a81070ba37

View File

@ -1483,8 +1483,8 @@ static int set_connectable(struct sock *sk, struct hci_dev *hdev, void *data,
if (err < 0) {
mgmt_pending_remove(cmd);
if (err == -ENODATA)
err = send_settings_rsp(sk, MGMT_OP_SET_CONNECTABLE,
hdev);
err = set_connectable_update_settings(hdev, sk,
cp->val);
goto failed;
}