mirror of
https://github.com/torvalds/linux.git
synced 2024-11-26 14:12:06 +00:00
net: ethtool: Add impedance mismatch result code to cable test
Some PHYs can recognize during a cable test if the impedance in the cable is okay. They can detect reflections caused by impedance discontinuity between a regular 100 Ohm cable and an abnormal part with a higher or lower impedance. This commit introduces a new result code: ETHTOOL_A_CABLE_RESULT_CODE_IMPEDANCE_MISMATCH, which represents the results of a cable test indicating issues with impedance integrity. Signed-off-by: Pawel Dembicki <paweldembicki@gmail.com> Reviewed-by: Andrew Lunn <andrew@lunn.ch> Link: https://lore.kernel.org/r/20240402201123.2961909-2-paweldembicki@gmail.com Signed-off-by: Jakub Kicinski <kuba@kernel.org>
This commit is contained in:
parent
ada9841e3e
commit
9cc8a6e626
@ -515,6 +515,10 @@ enum {
|
||||
ETHTOOL_A_CABLE_RESULT_CODE_OPEN,
|
||||
ETHTOOL_A_CABLE_RESULT_CODE_SAME_SHORT,
|
||||
ETHTOOL_A_CABLE_RESULT_CODE_CROSS_SHORT,
|
||||
/* detected reflection caused by the impedance discontinuity between
|
||||
* a regular 100 Ohm cable and a part with the abnormal impedance value
|
||||
*/
|
||||
ETHTOOL_A_CABLE_RESULT_CODE_IMPEDANCE_MISMATCH,
|
||||
};
|
||||
|
||||
enum {
|
||||
|
Loading…
Reference in New Issue