[PATCH] sk98lin: remove PCI id info for cards for conflicting devices

Fix PCI device id issues with sk98lin driver.
1. DLINK 530-T card has no Vital Product Data (VPD) area so the sk98lin
   driver won't work. (skge does however)
2. Remove commented out Yukon2 stuff
3. Restrict Linksys card to revisions that don't conflict with r8169 version.

Signed-off-by: Stephen Hemminger <shemminger@osdl.org>
Signed-off-by: Jeff Garzik <jgarzik@pobox.com>
This commit is contained in:
Stephen Hemminger 2005-09-13 10:02:44 -07:00 committed by Jeff Garzik
parent d8ac10639b
commit 9734c3fc89

View File

@ -5216,17 +5216,15 @@ static struct pci_device_id skge_pci_tbl[] = {
{ PCI_VENDOR_ID_3COM, 0x80eb, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
{ PCI_VENDOR_ID_SYSKONNECT, 0x4300, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
{ PCI_VENDOR_ID_SYSKONNECT, 0x4320, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
{ PCI_VENDOR_ID_DLINK, 0x4c00, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
/* DLink card does not have valid VPD so this driver gags
* { PCI_VENDOR_ID_DLINK, 0x4c00, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
*/
{ PCI_VENDOR_ID_MARVELL, 0x4320, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
#if 0 /* don't handle Yukon2 cards at the moment -- mlindner@syskonnect.de */
{ PCI_VENDOR_ID_MARVELL, 0x4360, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
{ PCI_VENDOR_ID_MARVELL, 0x4361, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
#endif
{ PCI_VENDOR_ID_MARVELL, 0x5005, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
{ PCI_VENDOR_ID_CNET, 0x434e, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
{ PCI_VENDOR_ID_LINKSYS, 0x1032, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
{ PCI_VENDOR_ID_LINKSYS, 0x1032, PCI_ANY_ID, 0x0015, },
{ PCI_VENDOR_ID_LINKSYS, 0x1064, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
{ 0, }
{ 0 }
};
MODULE_DEVICE_TABLE(pci, skge_pci_tbl);