iwlwifi: make sure runtime calibration is enabled after association

Clear the "start calib" flag only for new association,
The flag will be set in post_associate function to trigger
the runtime calibration. Set this flag to "0" will stop the
runtime sensitivity calibration

Signed-off-by: Wey-Yi Guy <wey-yi.w.guy@intel.com>
This commit is contained in:
Wey-Yi Guy 2010-09-03 11:42:04 -07:00
parent ea196fdbb9
commit 8f1d968721

View File

@ -226,9 +226,8 @@ int iwl_commit_rxon(struct iwl_priv *priv, struct iwl_rxon_context *ctx)
return ret;
}
}
priv->start_calib = 0;
if (new_assoc) {
priv->start_calib = 0;
/* Apply the new configuration
* RXON assoc doesn't clear the station table in uCode,
*/