sparc32, leon: Do not overwrite previously set irq flow handlers

This is needed because when scan_of_devices finds the GAISLER_GPTIMER
core that corresponds to the SMP "ticker" timer, the previously set
proper irq flow handler gets overwritten with an incorrect one. This
leads to very flaky timer interrupt handling on some hardware. Proper
updates to handlers can still be done using leon_update_virq_handling.

Signed-off-by: Andreas Larsson <andreas@gaisler.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Andreas Larsson 2013-04-21 21:23:06 +00:00 committed by David S. Miller
parent 75e448036b
commit 6e4741e73b

View File

@ -213,6 +213,7 @@ unsigned int leon_build_device_irq(unsigned int real_irq,
{
unsigned int irq;
unsigned long mask;
struct irq_desc *desc;
irq = 0;
mask = leon_get_irqmask(real_irq);
@ -226,9 +227,12 @@ unsigned int leon_build_device_irq(unsigned int real_irq,
if (do_ack)
mask |= LEON_DO_ACK_HW;
irq_set_chip_and_handler_name(irq, &leon_irq,
flow_handler, name);
irq_set_chip_data(irq, (void *)mask);
desc = irq_to_desc(irq);
if (!desc || !desc->handle_irq || desc->handle_irq == handle_bad_irq) {
irq_set_chip_and_handler_name(irq, &leon_irq,
flow_handler, name);
irq_set_chip_data(irq, (void *)mask);
}
out:
return irq;