clocksource: sunxi: Stop timer from ticking before enabling interrupts

The sun4i timer can still be ticking when we enable the interrupt.
If another timer is actually used (A7 architected timer, for example),
odds are that the interrupt will eventually fire with the event_handler
pointer being NULL.

The obvious fix it to stop the timer before registering the interrupt.

Observed and tested on sun7i (cubietruck).

Cc: Daniel Lezcano <daniel.lezcano@linaro.org>
Acked-by: Maxime Ripard <maxime.ripard@free-electrons.com>
Signed-off-by: Marc Zyngier <marc.zyngier@arm.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
This commit is contained in:
Marc Zyngier 2013-12-02 09:29:35 +00:00 committed by Daniel Lezcano
parent 4c4b053235
commit 6db50bb675

View File

@ -179,6 +179,9 @@ static void __init sun4i_timer_init(struct device_node *node)
writel(TIMER_CTL_CLK_SRC(TIMER_CTL_CLK_SRC_OSC24M),
timer_base + TIMER_CTL_REG(0));
/* Make sure timer is stopped before playing with interrupts */
sun4i_clkevt_time_stop(0);
ret = setup_irq(irq, &sun4i_timer_irq);
if (ret)
pr_warn("failed to setup irq %d\n", irq);