Documentation: iavf: Update the Intel LAN driver doc for iavf
Update the LAN driver documentation to include the latest feature implementation and driver capabilities. Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com> Tested-by: Aaron Brown <aaron.f.brown@intel.com>
This commit is contained in:
parent
10ce2c00cf
commit
675ab6509a
@ -10,11 +10,15 @@ Copyright(c) 2013-2018 Intel Corporation.
|
||||
Contents
|
||||
========
|
||||
|
||||
- Overview
|
||||
- Identifying Your Adapter
|
||||
- Additional Configurations
|
||||
- Known Issues/Troubleshooting
|
||||
- Support
|
||||
|
||||
Overview
|
||||
========
|
||||
|
||||
This file describes the iavf Linux* Base Driver. This driver was formerly
|
||||
called i40evf.
|
||||
|
||||
@ -27,6 +31,7 @@ The guest OS loading the iavf driver must support MSI-X interrupts.
|
||||
|
||||
Identifying Your Adapter
|
||||
========================
|
||||
|
||||
The driver in this kernel is compatible with devices based on the following:
|
||||
* Intel(R) XL710 X710 Virtual Function
|
||||
* Intel(R) X722 Virtual Function
|
||||
@ -50,9 +55,10 @@ Link messages will not be displayed to the console if the distribution is
|
||||
restricting system messages. In order to see network driver link messages on
|
||||
your console, set dmesg to eight by entering the following::
|
||||
|
||||
dmesg -n 8
|
||||
# dmesg -n 8
|
||||
|
||||
NOTE: This setting is not saved across reboots.
|
||||
NOTE:
|
||||
This setting is not saved across reboots.
|
||||
|
||||
ethtool
|
||||
-------
|
||||
@ -72,11 +78,11 @@ then requests from that VF to set VLAN tag stripping will be ignored.
|
||||
To enable/disable VLAN tag stripping for a VF, issue the following command
|
||||
from inside the VM in which you are running the VF::
|
||||
|
||||
ethtool -K <if_name> rxvlan on/off
|
||||
# ethtool -K <if_name> rxvlan on/off
|
||||
|
||||
or alternatively::
|
||||
|
||||
ethtool --offload <if_name> rxvlan on/off
|
||||
# ethtool --offload <if_name> rxvlan on/off
|
||||
|
||||
Adaptive Virtual Function
|
||||
-------------------------
|
||||
@ -91,21 +97,21 @@ additional features depending on what features are available in the PF with
|
||||
which the AVF is associated. The following are base mode features:
|
||||
|
||||
- 4 Queue Pairs (QP) and associated Configuration Status Registers (CSRs)
|
||||
for Tx/Rx.
|
||||
- i40e descriptors and ring format.
|
||||
- Descriptor write-back completion.
|
||||
- 1 control queue, with i40e descriptors, CSRs and ring format.
|
||||
- 5 MSI-X interrupt vectors and corresponding i40e CSRs.
|
||||
- 1 Interrupt Throttle Rate (ITR) index.
|
||||
- 1 Virtual Station Interface (VSI) per VF.
|
||||
for Tx/Rx
|
||||
- i40e descriptors and ring format
|
||||
- Descriptor write-back completion
|
||||
- 1 control queue, with i40e descriptors, CSRs and ring format
|
||||
- 5 MSI-X interrupt vectors and corresponding i40e CSRs
|
||||
- 1 Interrupt Throttle Rate (ITR) index
|
||||
- 1 Virtual Station Interface (VSI) per VF
|
||||
- 1 Traffic Class (TC), TC0
|
||||
- Receive Side Scaling (RSS) with 64 entry indirection table and key,
|
||||
configured through the PF.
|
||||
- 1 unicast MAC address reserved per VF.
|
||||
- 16 MAC address filters for each VF.
|
||||
- Stateless offloads - non-tunneled checksums.
|
||||
- AVF device ID.
|
||||
- HW mailbox is used for VF to PF communications (including on Windows).
|
||||
configured through the PF
|
||||
- 1 unicast MAC address reserved per VF
|
||||
- 16 MAC address filters for each VF
|
||||
- Stateless offloads - non-tunneled checksums
|
||||
- AVF device ID
|
||||
- HW mailbox is used for VF to PF communications (including on Windows)
|
||||
|
||||
IEEE 802.1ad (QinQ) Support
|
||||
---------------------------
|
||||
@ -117,8 +123,8 @@ VLAN ID, among other uses.
|
||||
|
||||
The following are examples of how to configure 802.1ad (QinQ)::
|
||||
|
||||
ip link add link eth0 eth0.24 type vlan proto 802.1ad id 24
|
||||
ip link add link eth0.24 eth0.24.371 type vlan proto 802.1Q id 371
|
||||
# ip link add link eth0 eth0.24 type vlan proto 802.1ad id 24
|
||||
# ip link add link eth0.24 eth0.24.371 type vlan proto 802.1Q id 371
|
||||
|
||||
Where "24" and "371" are example VLAN IDs.
|
||||
|
||||
@ -133,6 +139,19 @@ specific application. This can reduce latency for the specified application,
|
||||
and allow Tx traffic to be rate limited per application. Follow the steps below
|
||||
to set ADq.
|
||||
|
||||
Requirements:
|
||||
|
||||
- The sch_mqprio, act_mirred and cls_flower modules must be loaded
|
||||
- The latest version of iproute2
|
||||
- If another driver (for example, DPDK) has set cloud filters, you cannot
|
||||
enable ADQ
|
||||
- Depending on the underlying PF device, ADQ cannot be enabled when the
|
||||
following features are enabled:
|
||||
|
||||
+ Data Center Bridging (DCB)
|
||||
+ Multiple Functions per Port (MFP)
|
||||
+ Sideband Filters
|
||||
|
||||
1. Create traffic classes (TCs). Maximum of 8 TCs can be created per interface.
|
||||
The shaper bw_rlimit parameter is optional.
|
||||
|
||||
@ -141,9 +160,9 @@ to 1Gbit for tc0 and 3Gbit for tc1.
|
||||
|
||||
::
|
||||
|
||||
# tc qdisc add dev <interface> root mqprio num_tc 2 map 0 0 0 0 1 1 1 1
|
||||
queues 16@0 16@16 hw 1 mode channel shaper bw_rlimit min_rate 1Gbit 2Gbit
|
||||
max_rate 1Gbit 3Gbit
|
||||
tc qdisc add dev <interface> root mqprio num_tc 2 map 0 0 0 0 1 1 1 1
|
||||
queues 16@0 16@16 hw 1 mode channel shaper bw_rlimit min_rate 1Gbit 2Gbit
|
||||
max_rate 1Gbit 3Gbit
|
||||
|
||||
map: priority mapping for up to 16 priorities to tcs (e.g. map 0 0 0 0 1 1 1 1
|
||||
sets priorities 0-3 to use tc0 and 4-7 to use tc1)
|
||||
@ -162,6 +181,10 @@ Totals must be equal or less than port speed.
|
||||
For example: min_rate 1Gbit 3Gbit: Verify bandwidth limit using network
|
||||
monitoring tools such as ifstat or sar –n DEV [interval] [number of samples]
|
||||
|
||||
NOTE:
|
||||
Setting up channels via ethtool (ethtool -L) is not supported when the
|
||||
TCs are configured using mqprio.
|
||||
|
||||
2. Enable HW TC offload on interface::
|
||||
|
||||
# ethtool -K <interface> hw-tc-offload on
|
||||
@ -171,16 +194,16 @@ monitoring tools such as ifstat or sar –n DEV [interval] [number of samples]
|
||||
# tc qdisc add dev <interface> ingress
|
||||
|
||||
NOTES:
|
||||
- Run all tc commands from the iproute2 <pathtoiproute2>/tc/ directory.
|
||||
- ADq is not compatible with cloud filters.
|
||||
- Run all tc commands from the iproute2 <pathtoiproute2>/tc/ directory
|
||||
- ADq is not compatible with cloud filters
|
||||
- Setting up channels via ethtool (ethtool -L) is not supported when the TCs
|
||||
are configured using mqprio.
|
||||
are configured using mqprio
|
||||
- You must have iproute2 latest version
|
||||
- NVM version 6.01 or later is required.
|
||||
- NVM version 6.01 or later is required
|
||||
- ADq cannot be enabled when any the following features are enabled: Data
|
||||
Center Bridging (DCB), Multiple Functions per Port (MFP), or Sideband Filters.
|
||||
Center Bridging (DCB), Multiple Functions per Port (MFP), or Sideband Filters
|
||||
- If another driver (for example, DPDK) has set cloud filters, you cannot
|
||||
enable ADq.
|
||||
enable ADq
|
||||
- Tunnel filters are not supported in ADq. If encapsulated packets do arrive
|
||||
in non-tunnel mode, filtering will be done on the inner headers. For example,
|
||||
for VXLAN traffic in non-tunnel mode, PCTYPE is identified as a VXLAN
|
||||
@ -198,6 +221,16 @@ NOTES:
|
||||
Known Issues/Troubleshooting
|
||||
============================
|
||||
|
||||
Bonding fails with VFs bound to an Intel(R) Ethernet Controller 700 series device
|
||||
---------------------------------------------------------------------------------
|
||||
If you bind Virtual Functions (VFs) to an Intel(R) Ethernet Controller 700
|
||||
series based device, the VF slaves may fail when they become the active slave.
|
||||
If the MAC address of the VF is set by the PF (Physical Function) of the
|
||||
device, when you add a slave, or change the active-backup slave, Linux bonding
|
||||
tries to sync the backup slave's MAC address to the same MAC address as the
|
||||
active slave. Linux bonding will fail at this point. This issue will not occur
|
||||
if the VF's MAC address is not set by the PF.
|
||||
|
||||
Traffic Is Not Being Passed Between VM and Client
|
||||
-------------------------------------------------
|
||||
You may not be able to pass traffic between a client system and a
|
||||
@ -215,13 +248,28 @@ Do not unload a port's driver if a Virtual Function (VF) with an active Virtual
|
||||
Machine (VM) is bound to it. Doing so will cause the port to appear to hang.
|
||||
Once the VM shuts down, or otherwise releases the VF, the command will complete.
|
||||
|
||||
Using four traffic classes fails
|
||||
--------------------------------
|
||||
Do not try to reserve more than three traffic classes in the iavf driver. Doing
|
||||
so will fail to set any traffic classes and will cause the driver to write
|
||||
errors to stdout. Use a maximum of three queues to avoid this issue.
|
||||
|
||||
Multiple log error messages on iavf driver removal
|
||||
--------------------------------------------------
|
||||
If you have several VFs and you remove the iavf driver, several instances of
|
||||
the following log errors are written to the log::
|
||||
|
||||
Unable to send opcode 2 to PF, err I40E_ERR_QUEUE_EMPTY, aq_err ok
|
||||
Unable to send the message to VF 2 aq_err 12
|
||||
ARQ Overflow Error detected
|
||||
|
||||
Virtual machine does not get link
|
||||
---------------------------------
|
||||
If the virtual machine has more than one virtual port assigned to it, and those
|
||||
virtual ports are bound to different physical ports, you may not get link on
|
||||
all of the virtual ports. The following command may work around the issue::
|
||||
|
||||
ethtool -r <PF>
|
||||
# ethtool -r <PF>
|
||||
|
||||
Where <PF> is the PF interface in the host, for example: p5p1. You may need to
|
||||
run the command more than once to get link on all virtual ports.
|
||||
@ -251,12 +299,13 @@ traffic.
|
||||
If you have multiple interfaces in a server, either turn on ARP filtering by
|
||||
entering::
|
||||
|
||||
echo 1 > /proc/sys/net/ipv4/conf/all/arp_filter
|
||||
# echo 1 > /proc/sys/net/ipv4/conf/all/arp_filter
|
||||
|
||||
NOTE: This setting is not saved across reboots. The configuration change can be
|
||||
made permanent by adding the following line to the file /etc/sysctl.conf::
|
||||
NOTE:
|
||||
This setting is not saved across reboots. The configuration change can be
|
||||
made permanent by adding the following line to the file /etc/sysctl.conf::
|
||||
|
||||
net.ipv4.conf.all.arp_filter = 1
|
||||
net.ipv4.conf.all.arp_filter = 1
|
||||
|
||||
Another alternative is to install the interfaces in separate broadcast domains
|
||||
(either in different switches or in a switch partitioned to VLANs).
|
||||
|