From 624bf42c2e3930acca9fcfc340b2fa38e712da84 Mon Sep 17 00:00:00 2001 From: Yevgeny Kliteynik Date: Sun, 12 Dec 2021 16:19:58 +0200 Subject: [PATCH] net/mlx5: DR, Fix querying eswitch manager vport for ECPF On BlueField the E-Switch manager is the ECPF (vport 0xFFFE), but when querying capabilities of ECPF eswitch manager, need to query vport 0 with other_vport = 0. Fixes: 9091b821aaa4 ("net/mlx5: DR, Handle eswitch manager and uplink vports separately") Signed-off-by: Yevgeny Kliteynik Reviewed-by: Alex Vesker Signed-off-by: Saeed Mahameed --- drivers/net/ethernet/mellanox/mlx5/core/steering/dr_domain.c | 4 +--- 1 file changed, 1 insertion(+), 3 deletions(-) diff --git a/drivers/net/ethernet/mellanox/mlx5/core/steering/dr_domain.c b/drivers/net/ethernet/mellanox/mlx5/core/steering/dr_domain.c index f6e6d9209766..c54cc45f63dc 100644 --- a/drivers/net/ethernet/mellanox/mlx5/core/steering/dr_domain.c +++ b/drivers/net/ethernet/mellanox/mlx5/core/steering/dr_domain.c @@ -164,9 +164,7 @@ static int dr_domain_query_vport(struct mlx5dr_domain *dmn, static int dr_domain_query_esw_mngr(struct mlx5dr_domain *dmn) { - return dr_domain_query_vport(dmn, - dmn->info.caps.is_ecpf ? MLX5_VPORT_ECPF : 0, - false, + return dr_domain_query_vport(dmn, 0, false, &dmn->info.caps.vports.esw_manager_caps); }