ACPI: battery: Convert discharge energy rate to current properly
ACPI battery interface reports its state either in mW or in mA, and discharge rate in your case is reported in mW. power_supply interface does not have such a parameter, so current_now parameter is used for all cases. But in case of mW, reported discharge should be converted into mA. Signed-off-by: Alexey Starikovskiy <astarikovskiy@suse.de> Tested-by: Ferenc Wagner <wferi@niif.hu> Signed-off-by: Len Brown <len.brown@intel.com>
This commit is contained in:
parent
7b4d469228
commit
558073dd56
@ -174,6 +174,15 @@ static int acpi_battery_get_property(struct power_supply *psy,
|
||||
break;
|
||||
case POWER_SUPPLY_PROP_CURRENT_NOW:
|
||||
val->intval = battery->current_now * 1000;
|
||||
/* if power units are mW, convert to mA by
|
||||
dividing by current voltage (mV/1000) */
|
||||
if (!battery->power_unit) {
|
||||
if (battery->voltage_now) {
|
||||
val->intval /= battery->voltage_now;
|
||||
val->intval *= 1000;
|
||||
} else
|
||||
val->intval = -1;
|
||||
}
|
||||
break;
|
||||
case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN:
|
||||
case POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN:
|
||||
|
Loading…