USB: cdc-acm: fix runtime PM imbalance at shutdown

Make sure only to decrement the PM counters if they were actually
incremented.

Note that the USB PM counter, but not necessarily the driver core PM
counter, is reset when the interface is unbound.

Fixes: 11ea859d64 ("USB: additional power savings for cdc-acm devices
that support remote wakeup")

Signed-off-by: Johan Hovold <jhovold@gmail.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
Johan Hovold 2014-05-26 19:23:45 +02:00 committed by Greg Kroah-Hartman
parent e4c36076c2
commit 5292afa657

View File

@ -590,12 +590,13 @@ static void acm_port_shutdown(struct tty_port *port)
struct urb *urb;
struct acm_wb *wb;
int i;
int pm_err;
dev_dbg(&acm->control->dev, "%s\n", __func__);
mutex_lock(&acm->mutex);
if (!acm->disconnected) {
usb_autopm_get_interface(acm->control);
pm_err = usb_autopm_get_interface(acm->control);
acm_set_control(acm, acm->ctrlout = 0);
for (;;) {
@ -613,6 +614,7 @@ static void acm_port_shutdown(struct tty_port *port)
for (i = 0; i < acm->rx_buflimit; i++)
usb_kill_urb(acm->read_urbs[i]);
acm->control->needs_remote_wakeup = 0;
if (!pm_err)
usb_autopm_put_interface(acm->control);
}
mutex_unlock(&acm->mutex);