mirror of
https://github.com/torvalds/linux.git
synced 2024-12-20 01:52:13 +00:00
power: supply: charger-manager: Prepare for const properties
This prepares the driver to work with the properties entry in power_supply_desc marked as const. Reviewed-by: Enric Balletbo i Serra <enric.balletbo@collabora.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
parent
de46e02893
commit
4cb3825859
@ -1422,7 +1422,9 @@ static int charger_manager_prepare_sysfs(struct charger_manager *cm)
|
||||
}
|
||||
|
||||
static int cm_init_thermal_data(struct charger_manager *cm,
|
||||
struct power_supply *fuel_gauge)
|
||||
struct power_supply *fuel_gauge,
|
||||
enum power_supply_property *properties,
|
||||
size_t *num_properties)
|
||||
{
|
||||
struct charger_desc *desc = cm->desc;
|
||||
union power_supply_propval val;
|
||||
@ -1433,9 +1435,8 @@ static int cm_init_thermal_data(struct charger_manager *cm,
|
||||
POWER_SUPPLY_PROP_TEMP, &val);
|
||||
|
||||
if (!ret) {
|
||||
cm->charger_psy_desc.properties[cm->charger_psy_desc.num_properties] =
|
||||
POWER_SUPPLY_PROP_TEMP;
|
||||
cm->charger_psy_desc.num_properties++;
|
||||
properties[*num_properties] = POWER_SUPPLY_PROP_TEMP;
|
||||
(*num_properties)++;
|
||||
cm->desc->measure_battery_temp = true;
|
||||
}
|
||||
#ifdef CONFIG_THERMAL
|
||||
@ -1446,9 +1447,8 @@ static int cm_init_thermal_data(struct charger_manager *cm,
|
||||
return PTR_ERR(cm->tzd_batt);
|
||||
|
||||
/* Use external thermometer */
|
||||
cm->charger_psy_desc.properties[cm->charger_psy_desc.num_properties] =
|
||||
POWER_SUPPLY_PROP_TEMP_AMBIENT;
|
||||
cm->charger_psy_desc.num_properties++;
|
||||
properties[*num_properties] = POWER_SUPPLY_PROP_TEMP_AMBIENT;
|
||||
(*num_properties)++;
|
||||
cm->desc->measure_battery_temp = true;
|
||||
ret = 0;
|
||||
}
|
||||
@ -1621,6 +1621,8 @@ static int charger_manager_probe(struct platform_device *pdev)
|
||||
int j = 0;
|
||||
union power_supply_propval val;
|
||||
struct power_supply *fuel_gauge;
|
||||
enum power_supply_property *properties;
|
||||
size_t num_properties;
|
||||
struct power_supply_config psy_cfg = {};
|
||||
|
||||
if (IS_ERR(desc)) {
|
||||
@ -1717,18 +1719,17 @@ static int charger_manager_probe(struct platform_device *pdev)
|
||||
cm->charger_psy_desc.name = cm->psy_name_buf;
|
||||
|
||||
/* Allocate for psy properties because they may vary */
|
||||
cm->charger_psy_desc.properties =
|
||||
devm_kcalloc(&pdev->dev,
|
||||
properties = devm_kcalloc(&pdev->dev,
|
||||
ARRAY_SIZE(default_charger_props) +
|
||||
NUM_CHARGER_PSY_OPTIONAL,
|
||||
sizeof(enum power_supply_property), GFP_KERNEL);
|
||||
if (!cm->charger_psy_desc.properties)
|
||||
sizeof(*properties), GFP_KERNEL);
|
||||
if (!properties)
|
||||
return -ENOMEM;
|
||||
|
||||
memcpy(cm->charger_psy_desc.properties, default_charger_props,
|
||||
memcpy(properties, default_charger_props,
|
||||
sizeof(enum power_supply_property) *
|
||||
ARRAY_SIZE(default_charger_props));
|
||||
cm->charger_psy_desc.num_properties = psy_default.num_properties;
|
||||
num_properties = psy_default.num_properties;
|
||||
|
||||
/* Find which optional psy-properties are available */
|
||||
fuel_gauge = power_supply_get_by_name(desc->psy_fuel_gauge);
|
||||
@ -1739,25 +1740,28 @@ static int charger_manager_probe(struct platform_device *pdev)
|
||||
}
|
||||
if (!power_supply_get_property(fuel_gauge,
|
||||
POWER_SUPPLY_PROP_CHARGE_NOW, &val)) {
|
||||
cm->charger_psy_desc.properties[cm->charger_psy_desc.num_properties] =
|
||||
properties[num_properties] =
|
||||
POWER_SUPPLY_PROP_CHARGE_NOW;
|
||||
cm->charger_psy_desc.num_properties++;
|
||||
num_properties++;
|
||||
}
|
||||
if (!power_supply_get_property(fuel_gauge,
|
||||
POWER_SUPPLY_PROP_CURRENT_NOW,
|
||||
&val)) {
|
||||
cm->charger_psy_desc.properties[cm->charger_psy_desc.num_properties] =
|
||||
properties[num_properties] =
|
||||
POWER_SUPPLY_PROP_CURRENT_NOW;
|
||||
cm->charger_psy_desc.num_properties++;
|
||||
num_properties++;
|
||||
}
|
||||
|
||||
ret = cm_init_thermal_data(cm, fuel_gauge);
|
||||
ret = cm_init_thermal_data(cm, fuel_gauge, properties, &num_properties);
|
||||
if (ret) {
|
||||
dev_err(&pdev->dev, "Failed to initialize thermal data\n");
|
||||
cm->desc->measure_battery_temp = false;
|
||||
}
|
||||
power_supply_put(fuel_gauge);
|
||||
|
||||
cm->charger_psy_desc.properties = properties;
|
||||
cm->charger_psy_desc.num_properties = num_properties;
|
||||
|
||||
INIT_DELAYED_WORK(&cm->fullbatt_vchk_work, fullbatt_vchk);
|
||||
|
||||
/* Register sysfs entry for charger(regulator) */
|
||||
|
Loading…
Reference in New Issue
Block a user