perf vendor events: Update metrics for CascadelakeX
Based on TMA_metrics-full.csv version 4.3 at 01.org: https://download.01.org/perfmon/ Events are updated to version 1.14: https://download.01.org/perfmon/CLX Json files generated by: https://github.com/intel/event-converter-for-linux-perf Tested: ... 6: Parse event definition strings : Ok 7: Simple expression parser : Ok ... 9: Parse perf pmu format : Ok 10: PMU events : 10.1: PMU event table sanity : Ok 10.2: PMU event map aliases : Ok 10.3: Parsing of PMU event table metrics : Ok 10.4: Parsing of PMU event table metrics with fake PMUs : Ok ... 68: Parse and process metrics : Ok ... 88: perf stat metrics (shadow stat) test : Ok 89: perf all metricgroups test : Ok 90: perf all metrics test : FAILED! 91: perf all PMU test : Ok ... Test 90 failed due to MEM_PMM_Read_Latency as the test machine lacks optane memory, and the divide by 0 causes the metric not to print - which is intended behavior. Reviewed-by: Kan Liang <kan.liang@linux.intel.com> Signed-off-by: Ian Rogers <irogers@google.com> Cc: Alexander Shishkin <alexander.shishkin@linux.intel.com> Cc: Alexandre Torgue <alexandre.torgue@foss.st.com> Cc: Andi Kleen <ak@linux.intel.com> Cc: Ingo Molnar <mingo@redhat.com> Cc: James Clark <james.clark@arm.com> Cc: Jiri Olsa <jolsa@kernel.org> Cc: John Garry <john.garry@huawei.com> Cc: Mark Rutland <mark.rutland@arm.com> Cc: Maxime Coquelin <mcoquelin.stm32@gmail.com> Cc: Namhyung Kim <namhyung@kernel.org> Cc: Peter Zijlstra <peterz@infradead.org> Cc: Stephane Eranian <eranian@google.com> Cc: Zhengjun Xing <zhengjun.xing@linux.intel.com> Link: https://lore.kernel.org/r/20220201015858.1226914-5-irogers@google.com Signed-off-by: Arnaldo Carvalho de Melo <acme@redhat.com>
This commit is contained in:
parent
34cb72efdc
commit
49898fef49
File diff suppressed because it is too large
Load Diff
File diff suppressed because one or more lines are too long
@ -1,37 +1,41 @@
|
||||
[
|
||||
{
|
||||
"BriefDescription": "Number of SSE/AVX computational 128-bit packed double precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 2 computation operations, one for each element. Applies to SSE* and AVX* packed double precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT RSQRT14 RCP14 DPP FM(N)ADD/SUB. DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element.",
|
||||
"BriefDescription": "Counts once for most SIMD 128-bit packed computational double precision floating-point instructions retired. Counts twice for DPP and FM(N)ADD/SUB instructions retired.",
|
||||
"Counter": "0,1,2,3",
|
||||
"CounterHTOff": "0,1,2,3,4,5,6,7",
|
||||
"EventCode": "0xC7",
|
||||
"EventName": "FP_ARITH_INST_RETIRED.128B_PACKED_DOUBLE",
|
||||
"PublicDescription": "Counts once for most SIMD 128-bit packed computational double precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 2 computation operations, one for each element. Applies to packed double precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT DPP FM(N)ADD/SUB. DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
|
||||
"SampleAfterValue": "2000003",
|
||||
"UMask": "0x4"
|
||||
},
|
||||
{
|
||||
"BriefDescription": "Number of SSE/AVX computational 128-bit packed single precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 4 computation operations, one for each element. Applies to SSE* and AVX* packed single precision floating-point instructions: ADD SUB MUL DIV MIN MAX RCP14 RSQRT14 SQRT DPP FM(N)ADD/SUB. DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element.",
|
||||
"BriefDescription": "Counts once for most SIMD 128-bit packed computational single precision floating-point instruction retired. Counts twice for DPP and FM(N)ADD/SUB instructions retired.",
|
||||
"Counter": "0,1,2,3",
|
||||
"CounterHTOff": "0,1,2,3,4,5,6,7",
|
||||
"EventCode": "0xC7",
|
||||
"EventName": "FP_ARITH_INST_RETIRED.128B_PACKED_SINGLE",
|
||||
"PublicDescription": "Counts once for most SIMD 128-bit packed computational single precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 4 computation operations, one for each element. Applies to packed single precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT RSQRT RCP DPP FM(N)ADD/SUB. DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
|
||||
"SampleAfterValue": "2000003",
|
||||
"UMask": "0x8"
|
||||
},
|
||||
{
|
||||
"BriefDescription": "Number of SSE/AVX computational 256-bit packed double precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 4 computation operations, one for each element. Applies to SSE* and AVX* packed double precision floating-point instructions: ADD SUB MUL DIV MIN MAX RCP14 RSQRT14 SQRT DPP FM(N)ADD/SUB. DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element.",
|
||||
"BriefDescription": "Counts once for most SIMD 256-bit packed double computational precision floating-point instructions retired. Counts twice for DPP and FM(N)ADD/SUB instructions retired.",
|
||||
"Counter": "0,1,2,3",
|
||||
"CounterHTOff": "0,1,2,3,4,5,6,7",
|
||||
"EventCode": "0xC7",
|
||||
"EventName": "FP_ARITH_INST_RETIRED.256B_PACKED_DOUBLE",
|
||||
"PublicDescription": "Counts once for most SIMD 256-bit packed double computational precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 4 computation operations, one for each element. Applies to packed double precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT FM(N)ADD/SUB. FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
|
||||
"SampleAfterValue": "2000003",
|
||||
"UMask": "0x10"
|
||||
},
|
||||
{
|
||||
"BriefDescription": "Number of SSE/AVX computational 256-bit packed single precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 8 computation operations, one for each element. Applies to SSE* and AVX* packed single precision floating-point instructions: ADD SUB MUL DIV MIN MAX RCP14 RSQRT14 SQRT DPP FM(N)ADD/SUB. DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element.",
|
||||
"BriefDescription": "Counts once for most SIMD 256-bit packed single computational precision floating-point instructions retired. Counts twice for DPP and FM(N)ADD/SUB instructions retired.",
|
||||
"Counter": "0,1,2,3",
|
||||
"CounterHTOff": "0,1,2,3,4,5,6,7",
|
||||
"EventCode": "0xC7",
|
||||
"EventName": "FP_ARITH_INST_RETIRED.256B_PACKED_SINGLE",
|
||||
"PublicDescription": "Counts once for most SIMD 256-bit packed single computational precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 8 computation operations, one for each element. Applies to packed single precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT RSQRT RCP DPP FM(N)ADD/SUB. DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
|
||||
"SampleAfterValue": "2000003",
|
||||
"UMask": "0x20"
|
||||
},
|
||||
@ -41,6 +45,7 @@
|
||||
"CounterHTOff": "0,1,2,3,4,5,6,7",
|
||||
"EventCode": "0xC7",
|
||||
"EventName": "FP_ARITH_INST_RETIRED.512B_PACKED_DOUBLE",
|
||||
"PublicDescription": "Number of SSE/AVX computational 512-bit packed double precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 8 computation operations, one for each element. Applies to SSE* and AVX* packed double precision floating-point instructions: ADD SUB MUL DIV MIN MAX RCP14 RSQRT14 SQRT DPP FM(N)ADD/SUB. DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
|
||||
"SampleAfterValue": "2000003",
|
||||
"UMask": "0x40"
|
||||
},
|
||||
@ -50,27 +55,60 @@
|
||||
"CounterHTOff": "0,1,2,3,4,5,6,7",
|
||||
"EventCode": "0xC7",
|
||||
"EventName": "FP_ARITH_INST_RETIRED.512B_PACKED_SINGLE",
|
||||
"PublicDescription": "Number of SSE/AVX computational 512-bit packed single precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 16 computation operations, one for each element. Applies to SSE* and AVX* packed single precision floating-point instructions: ADD SUB MUL DIV MIN MAX RCP14 RSQRT14 SQRT DPP FM(N)ADD/SUB. DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
|
||||
"SampleAfterValue": "2000003",
|
||||
"UMask": "0x80"
|
||||
},
|
||||
{
|
||||
"BriefDescription": "Number of SSE/AVX computational scalar double precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 1 computation. Applies to SSE* and AVX* scalar double precision floating-point instructions: ADD SUB MUL DIV MIN MAX RCP14 RSQRT14 SQRT DPP FM(N)ADD/SUB. DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element.",
|
||||
"BriefDescription": "Counts once for most SIMD scalar computational double precision floating-point instructions retired. Counts twice for DPP and FM(N)ADD/SUB instructions retired.",
|
||||
"Counter": "0,1,2,3",
|
||||
"CounterHTOff": "0,1,2,3,4,5,6,7",
|
||||
"EventCode": "0xC7",
|
||||
"EventName": "FP_ARITH_INST_RETIRED.SCALAR_DOUBLE",
|
||||
"PublicDescription": "Counts once for most SIMD scalar computational double precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 1 computational operation. Applies to SIMD scalar double precision floating-point instructions: ADD SUB MUL DIV MIN MAX SQRT FM(N)ADD/SUB. FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
|
||||
"SampleAfterValue": "2000003",
|
||||
"UMask": "0x1"
|
||||
},
|
||||
{
|
||||
"BriefDescription": "Number of SSE/AVX computational scalar single precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 1 computation. Applies to SSE* and AVX* scalar single precision floating-point instructions: ADD SUB MUL DIV MIN MAX RCP14 RSQRT14 SQRT DPP FM(N)ADD/SUB. DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element.",
|
||||
"BriefDescription": "Counts once for most SIMD scalar computational single precision floating-point instructions retired. Counts twice for DPP and FM(N)ADD/SUB instructions retired.",
|
||||
"Counter": "0,1,2,3",
|
||||
"CounterHTOff": "0,1,2,3,4,5,6,7",
|
||||
"EventCode": "0xC7",
|
||||
"EventName": "FP_ARITH_INST_RETIRED.SCALAR_SINGLE",
|
||||
"PublicDescription": "Counts once for most SIMD scalar computational single precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 1 computational operation. Applies to SIMD scalar single precision floating-point instructions: ADD SUB MUL DIV MIN MAX SQRT RSQRT RCP FM(N)ADD/SUB. FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
|
||||
"SampleAfterValue": "2000003",
|
||||
"UMask": "0x2"
|
||||
},
|
||||
{
|
||||
"BriefDescription": "Intel AVX-512 computational 512-bit packed BFloat16 instructions retired.",
|
||||
"Counter": "0,1,2,3",
|
||||
"CounterHTOff": "0,1,2,3,4,5,6,7",
|
||||
"EventCode": "0xCF",
|
||||
"EventName": "FP_ARITH_INST_RETIRED2.128BIT_PACKED_BF16",
|
||||
"PublicDescription": "Counts once for each Intel AVX-512 computational 512-bit packed BFloat16 floating-point instruction retired. Applies to the ZMM based VDPBF16PS instruction. Each count represents 64 computation operations. This event is only supported on products formerly named Cooper Lake and is not supported on products formerly named Cascade Lake.",
|
||||
"SampleAfterValue": "2000003",
|
||||
"UMask": "0x20"
|
||||
},
|
||||
{
|
||||
"BriefDescription": "Intel AVX-512 computational 128-bit packed BFloat16 instructions retired.",
|
||||
"Counter": "0,1,2,3",
|
||||
"CounterHTOff": "0,1,2,3,4,5,6,7",
|
||||
"EventCode": "0xCF",
|
||||
"EventName": "FP_ARITH_INST_RETIRED2.256BIT_PACKED_BF16",
|
||||
"PublicDescription": "Counts once for each Intel AVX-512 computational 128-bit packed BFloat16 floating-point instruction retired. Applies to the XMM based VDPBF16PS instruction. Each count represents 16 computation operations. This event is only supported on products formerly named Cooper Lake and is not supported on products formerly named Cascade Lake.",
|
||||
"SampleAfterValue": "2000003",
|
||||
"UMask": "0x40"
|
||||
},
|
||||
{
|
||||
"BriefDescription": "Intel AVX-512 computational 256-bit packed BFloat16 instructions retired.",
|
||||
"Counter": "0,1,2,3",
|
||||
"CounterHTOff": "0,1,2,3,4,5,6,7",
|
||||
"EventCode": "0xCF",
|
||||
"EventName": "FP_ARITH_INST_RETIRED2.512BIT_PACKED_BF16",
|
||||
"PublicDescription": "Counts once for each Intel AVX-512 computational 256-bit packed BFloat16 floating-point instruction retired. Applies to the YMM based VDPBF16PS instruction. Each count represents 32 computation operations. This event is only supported on products formerly named Cooper Lake and is not supported on products formerly named Cascade Lake.",
|
||||
"SampleAfterValue": "2000003",
|
||||
"UMask": "0x80"
|
||||
},
|
||||
{
|
||||
"BriefDescription": "Cycles with any input/output SSE or FP assist",
|
||||
"Counter": "0,1,2,3",
|
||||
|
@ -30,7 +30,21 @@
|
||||
"UMask": "0x2"
|
||||
},
|
||||
{
|
||||
"BriefDescription": "Retired Instructions who experienced decode stream buffer (DSB - the decoded instruction-cache) miss.",
|
||||
"BriefDescription": "Retired Instructions who experienced DSB miss.",
|
||||
"Counter": "0,1,2,3",
|
||||
"CounterHTOff": "0,1,2,3",
|
||||
"EventCode": "0xC6",
|
||||
"EventName": "FRONTEND_RETIRED.ANY_DSB_MISS",
|
||||
"MSRIndex": "0x3F7",
|
||||
"MSRValue": "0x1",
|
||||
"PEBS": "1",
|
||||
"PublicDescription": "Counts retired Instructions that experienced DSB (Decode stream buffer i.e. the decoded instruction-cache) miss.",
|
||||
"SampleAfterValue": "100007",
|
||||
"TakenAlone": "1",
|
||||
"UMask": "0x1"
|
||||
},
|
||||
{
|
||||
"BriefDescription": "Retired Instructions who experienced a critical DSB miss.",
|
||||
"Counter": "0,1,2,3",
|
||||
"CounterHTOff": "0,1,2,3",
|
||||
"EventCode": "0xC6",
|
||||
@ -38,7 +52,7 @@
|
||||
"MSRIndex": "0x3F7",
|
||||
"MSRValue": "0x11",
|
||||
"PEBS": "1",
|
||||
"PublicDescription": "Counts retired Instructions that experienced DSB (Decode stream buffer i.e. the decoded instruction-cache) miss.",
|
||||
"PublicDescription": "Number of retired Instructions that experienced a critical DSB (Decode stream buffer i.e. the decoded instruction-cache) miss. Critical means stalls were exposed to the back-end as a result of the DSB miss.",
|
||||
"SampleAfterValue": "100007",
|
||||
"TakenAlone": "1",
|
||||
"UMask": "0x1"
|
||||
|
File diff suppressed because it is too large
Load Diff
File diff suppressed because it is too large
Load Diff
@ -435,6 +435,17 @@
|
||||
"PublicDescription": "Counts the number of instructions (EOMs) retired. Counting covers macro-fused instructions individually (that is, increments by two).",
|
||||
"SampleAfterValue": "2000003"
|
||||
},
|
||||
{
|
||||
"BriefDescription": "Number of all retired NOP instructions.",
|
||||
"Counter": "0,1,2,3",
|
||||
"CounterHTOff": "0,1,2,3,4,5,6,7",
|
||||
"Errata": "SKL091, SKL044",
|
||||
"EventCode": "0xC0",
|
||||
"EventName": "INST_RETIRED.NOP",
|
||||
"PEBS": "1",
|
||||
"SampleAfterValue": "2000003",
|
||||
"UMask": "0x2"
|
||||
},
|
||||
{
|
||||
"BriefDescription": "Precise instruction retired event with HW to reduce effect of PEBS shadow in IP distribution",
|
||||
"Counter": "1",
|
||||
|
@ -558,6 +558,18 @@
|
||||
"PublicDescription": "Counts clockticks of the 1GHz trafiic controller clock in the IIO unit.",
|
||||
"Unit": "IIO"
|
||||
},
|
||||
{
|
||||
"BriefDescription": "PCIe Completion Buffer Inserts of completions with data: Part 0-3",
|
||||
"Counter": "0,1,2,3",
|
||||
"EventCode": "0xC2",
|
||||
"EventName": "UNC_IIO_COMP_BUF_INSERTS.CMPD.ALL_PARTS",
|
||||
"FCMask": "0x4",
|
||||
"PerPkg": "1",
|
||||
"PortMask": "0x0f",
|
||||
"PublicDescription": "PCIe Completion Buffer Inserts of completions with data: Part 0-3",
|
||||
"UMask": "0x03",
|
||||
"Unit": "IIO"
|
||||
},
|
||||
{
|
||||
"BriefDescription": "PCIe Completion Buffer Inserts of completions with data: Part 0",
|
||||
"Counter": "0,1,2,3",
|
||||
@ -606,6 +618,17 @@
|
||||
"UMask": "0x03",
|
||||
"Unit": "IIO"
|
||||
},
|
||||
{
|
||||
"BriefDescription": "PCIe Completion Buffer occupancy of completions with data: Part 0-3",
|
||||
"Counter": "2,3",
|
||||
"EventCode": "0xD5",
|
||||
"EventName": "UNC_IIO_COMP_BUF_OCCUPANCY.CMPD.ALL_PARTS",
|
||||
"FCMask": "0x04",
|
||||
"PerPkg": "1",
|
||||
"PublicDescription": "PCIe Completion Buffer occupancy of completions with data: Part 0-3",
|
||||
"UMask": "0x0f",
|
||||
"Unit": "IIO"
|
||||
},
|
||||
{
|
||||
"BriefDescription": "PCIe Completion Buffer occupancy of completions with data: Part 0",
|
||||
"Counter": "2,3",
|
||||
|