net: phy: Remove the call to phy_mii_ioctl in phy_hwstamp_get/set

__phy_hwtstamp_set function were calling the phy_mii_ioctl function
which will then use the ifreq pointer to call the hwtstamp callback.
Now that ifreq has been removed from the hwstamp callback parameters
it seems more logical to not go through the phy_mii_ioctl function and pass
directly kernel_hwtstamp_config parameter to the hwtstamp callback.

Lets do the same for __phy_hwtstamp_get function and return directly
EOPNOTSUPP as SIOCGHWTSTAMP is not supported for now for the PHYs.

Signed-off-by: Kory Maincent <kory.maincent@bootlin.com>
Reviewed-by: Florian Fainelli <florian.fainelli@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Kory Maincent 2023-11-14 12:28:30 +01:00 committed by David S. Miller
parent 446e230582
commit 430dc3256d

View File

@ -486,7 +486,7 @@ int __phy_hwtstamp_get(struct phy_device *phydev,
if (!phydev)
return -ENODEV;
return phy_mii_ioctl(phydev, config->ifr, SIOCGHWTSTAMP);
return -EOPNOTSUPP;
}
/**
@ -503,7 +503,10 @@ int __phy_hwtstamp_set(struct phy_device *phydev,
if (!phydev)
return -ENODEV;
return phy_mii_ioctl(phydev, config->ifr, SIOCSHWTSTAMP);
if (phydev->mii_ts && phydev->mii_ts->hwtstamp)
return phydev->mii_ts->hwtstamp(phydev->mii_ts, config, extack);
return -EOPNOTSUPP;
}
/**