mirror of
https://github.com/torvalds/linux.git
synced 2024-11-28 07:01:32 +00:00
iio: light: vl6180: Correct ALS scale for non-default gain/integration time
The reported scale was only correct for the default settings of 100 ms integration time and gain 1. This aligns the reported scale with the behaviour of any other IIO driver and the documented ABI, but may require userspace changes if someone uses non-default settings. Signed-off-by: Stefan Brüns <stefan.bruens@rwth-aachen.de> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
e794bf6751
commit
3525d7cfb7
@ -315,9 +315,12 @@ static int vl6180_read_raw(struct iio_dev *indio_dev,
|
||||
case IIO_CHAN_INFO_SCALE:
|
||||
switch (chan->type) {
|
||||
case IIO_LIGHT:
|
||||
*val = 0; /* one ALS count is 0.32 Lux */
|
||||
*val2 = 320000;
|
||||
break;
|
||||
/* one ALS count is 0.32 Lux @ gain 1, IT 100 ms */
|
||||
*val = 32000; /* 0.32 * 1000 * 100 */
|
||||
*val2 = data->als_gain_milli * data->als_it_ms;
|
||||
|
||||
return IIO_VAL_FRACTIONAL;
|
||||
|
||||
case IIO_DISTANCE:
|
||||
*val = 0; /* sensor reports mm, scale to meter */
|
||||
*val2 = 1000;
|
||||
|
Loading…
Reference in New Issue
Block a user