mirror of
https://github.com/torvalds/linux.git
synced 2024-11-22 12:11:40 +00:00
rtc: stop warning for invalid alarms when the alarm is disabled
When the alarm is not enabled, it may never have been set and so we can't expect it to be valid. This will prevent the apparition of boot messages like this one: rtc rtc0: invalid alarm value: 2023-7-8 45:85:85 Link: https://lore.kernel.org/r/20230827221532.543353-1-alexandre.belloni@bootlin.com Signed-off-by: Alexandre Belloni <alexandre.belloni@bootlin.com>
This commit is contained in:
parent
7130856f56
commit
348c11a7d7
@ -376,7 +376,7 @@ int __rtc_read_alarm(struct rtc_device *rtc, struct rtc_wkalrm *alarm)
|
||||
err = rtc_valid_tm(&alarm->time);
|
||||
|
||||
done:
|
||||
if (err)
|
||||
if (err && alarm->enabled)
|
||||
dev_warn(&rtc->dev, "invalid alarm value: %ptR\n",
|
||||
&alarm->time);
|
||||
|
||||
|