rtc: stop warning for invalid alarms when the alarm is disabled

When the alarm is not enabled, it may never have been set and so we can't
expect it to be valid. This will prevent the apparition of boot messages
like this one:

rtc rtc0: invalid alarm value: 2023-7-8 45:85:85

Link: https://lore.kernel.org/r/20230827221532.543353-1-alexandre.belloni@bootlin.com
Signed-off-by: Alexandre Belloni <alexandre.belloni@bootlin.com>
This commit is contained in:
Alexandre Belloni 2023-08-28 00:15:31 +02:00
parent 7130856f56
commit 348c11a7d7

View File

@ -376,7 +376,7 @@ int __rtc_read_alarm(struct rtc_device *rtc, struct rtc_wkalrm *alarm)
err = rtc_valid_tm(&alarm->time);
done:
if (err)
if (err && alarm->enabled)
dev_warn(&rtc->dev, "invalid alarm value: %ptR\n",
&alarm->time);