ARM: dts: define default thermal-zones for exynos4
Trip points corresponding to the one defined in the exynos_tmu_data.c for Exynos4 have been included. This thermal-zones attribute is afterwards reused for Exynos4210, Exynos4412 and Exynos5250. Signed-off-by: Lukasz Majewski <l.majewski@samsung.com> Acked-by: Eduardo Valentin <edubezval@gmail.com> Signed-off-by: Kukjin Kim <kgene@kernel.org>
This commit is contained in:
parent
b350de6fa9
commit
328829a6ad
52
arch/arm/boot/dts/exynos4-cpu-thermal.dtsi
Normal file
52
arch/arm/boot/dts/exynos4-cpu-thermal.dtsi
Normal file
@ -0,0 +1,52 @@
|
||||
/*
|
||||
* Device tree sources for Exynos4 thermal zone
|
||||
*
|
||||
* Copyright (c) 2014 Lukasz Majewski <l.majewski@samsung.com>
|
||||
*
|
||||
* This program is free software; you can redistribute it and/or modify
|
||||
* it under the terms of the GNU General Public License version 2 as
|
||||
* published by the Free Software Foundation.
|
||||
*
|
||||
*/
|
||||
|
||||
#include <dt-bindings/thermal/thermal.h>
|
||||
|
||||
/ {
|
||||
thermal-zones {
|
||||
cpu_thermal: cpu-thermal {
|
||||
thermal-sensors = <&tmu 0>;
|
||||
polling-delay-passive = <0>;
|
||||
polling-delay = <0>;
|
||||
trips {
|
||||
cpu_alert0: cpu-alert-0 {
|
||||
temperature = <70000>; /* millicelsius */
|
||||
hysteresis = <10000>; /* millicelsius */
|
||||
type = "active";
|
||||
};
|
||||
cpu_alert1: cpu-alert-1 {
|
||||
temperature = <95000>; /* millicelsius */
|
||||
hysteresis = <10000>; /* millicelsius */
|
||||
type = "active";
|
||||
};
|
||||
cpu_alert2: cpu-alert-2 {
|
||||
temperature = <110000>; /* millicelsius */
|
||||
hysteresis = <10000>; /* millicelsius */
|
||||
type = "active";
|
||||
};
|
||||
cpu_crit0: cpu-crit-0 {
|
||||
temperature = <120000>; /* millicelsius */
|
||||
hysteresis = <0>; /* millicelsius */
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&cpu_alert0>;
|
||||
};
|
||||
map1 {
|
||||
trip = <&cpu_alert1>;
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
Loading…