IB/core: Set speed string to SDR for invalid active rates

Before commit f1b65df5a2 ("IB/mlx5: Add support for active_width and
active_speed in RoCE"), the mlx5_ib driver set default active_width and
active_speed to IB_WIDTH_4X and IB_SPEED_QDR.

Now, the active_width and active_speed are zeros if the RoCE port
is in DOWN state. The speed string should be set to " SDR" instead of
a blank string when active_speed is zero.

Signed-off-by: Honggang Li <honli@redhat.com>
Signed-off-by: Jason Gunthorpe <jgg@mellanox.com>
This commit is contained in:
Honggang Li 2018-03-15 17:02:13 +08:00 committed by Jason Gunthorpe
parent 7d9a935e16
commit 311d0da974

View File

@ -273,6 +273,7 @@ static ssize_t rate_show(struct ib_port *p, struct port_attribute *unused,
break;
case IB_SPEED_SDR:
default: /* default to SDR for invalid rates */
speed = " SDR";
rate = 25;
break;
}