thermal: cpu_cooling: Update always cpufreq policy with thermal constraints
Existing code updates cupfreq policy only while executing cpufreq_apply_cooling() function (i.e. when notify_device != NOTIFY_INVALID). It doesn't apply constraints when cpufreq policy update happens from any other place but it should update the cpufreq policy with thermal constraints every time when there is a cpufreq policy update, to keep state of cpufreq_cooling_device and max_feq of cpufreq policy in sync. For instance while resuming cpufreq updates cpufreq_policy and it restores default policy->usr_policy values irrespective of cooling device's cpufreq_state since notification gets missed because (notify_device == NOTIFY_INVALID). Another problem, is that userspace is able to change max_freq irrespective of cooling device's state, as notification gets missed. This patch modifies code to maintain a global cpufreq_dev_list and applies constraints of all matching cooling devices for policy's cpu when there is any policy update(ends up applying the lowest max_freq among the matching cpu cooling devices). This patch also removes redundant check (max_freq > policy->user_policy.max), as cpufreq framework takes care of user_policy constraints already where ever required, otherwise its causing an issue while increasing max_freq in normal scenerio as it restores max_freq with policy->user_policy.max which is old (smaller) value. Signed-off-by: Yadwinder Singh Brar <yadi.brar@samsung.com> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This commit is contained in:
parent
fc14f9c127
commit
2dcd851fe4
@ -50,15 +50,14 @@ struct cpufreq_cooling_device {
|
||||
unsigned int cpufreq_state;
|
||||
unsigned int cpufreq_val;
|
||||
struct cpumask allowed_cpus;
|
||||
struct list_head node;
|
||||
};
|
||||
static DEFINE_IDR(cpufreq_idr);
|
||||
static DEFINE_MUTEX(cooling_cpufreq_lock);
|
||||
|
||||
static unsigned int cpufreq_dev_count;
|
||||
|
||||
/* notify_table passes value to the CPUFREQ_ADJUST callback function. */
|
||||
#define NOTIFY_INVALID NULL
|
||||
static struct cpufreq_cooling_device *notify_device;
|
||||
static LIST_HEAD(cpufreq_dev_list);
|
||||
|
||||
/**
|
||||
* get_idr - function to get a unique id.
|
||||
@ -287,15 +286,12 @@ static int cpufreq_apply_cooling(struct cpufreq_cooling_device *cpufreq_device,
|
||||
|
||||
cpufreq_device->cpufreq_state = cooling_state;
|
||||
cpufreq_device->cpufreq_val = clip_freq;
|
||||
notify_device = cpufreq_device;
|
||||
|
||||
for_each_cpu(cpuid, mask) {
|
||||
if (is_cpufreq_valid(cpuid))
|
||||
cpufreq_update_policy(cpuid);
|
||||
}
|
||||
|
||||
notify_device = NOTIFY_INVALID;
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
@ -316,21 +312,28 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb,
|
||||
{
|
||||
struct cpufreq_policy *policy = data;
|
||||
unsigned long max_freq = 0;
|
||||
struct cpufreq_cooling_device *cpufreq_dev;
|
||||
|
||||
if (event != CPUFREQ_ADJUST || notify_device == NOTIFY_INVALID)
|
||||
if (event != CPUFREQ_ADJUST)
|
||||
return 0;
|
||||
|
||||
if (cpumask_test_cpu(policy->cpu, ¬ify_device->allowed_cpus))
|
||||
max_freq = notify_device->cpufreq_val;
|
||||
else
|
||||
return 0;
|
||||
mutex_lock(&cooling_cpufreq_lock);
|
||||
list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) {
|
||||
if (!cpumask_test_cpu(policy->cpu,
|
||||
&cpufreq_dev->allowed_cpus))
|
||||
continue;
|
||||
|
||||
/* Never exceed user_policy.max */
|
||||
if (max_freq > policy->user_policy.max)
|
||||
max_freq = policy->user_policy.max;
|
||||
if (!cpufreq_dev->cpufreq_val)
|
||||
cpufreq_dev->cpufreq_val = get_cpu_frequency(
|
||||
cpumask_any(&cpufreq_dev->allowed_cpus),
|
||||
cpufreq_dev->cpufreq_state);
|
||||
|
||||
max_freq = cpufreq_dev->cpufreq_val;
|
||||
|
||||
if (policy->max != max_freq)
|
||||
cpufreq_verify_within_limits(policy, 0, max_freq);
|
||||
}
|
||||
mutex_unlock(&cooling_cpufreq_lock);
|
||||
|
||||
return 0;
|
||||
}
|
||||
@ -486,6 +489,7 @@ __cpufreq_cooling_register(struct device_node *np,
|
||||
cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
|
||||
CPUFREQ_POLICY_NOTIFIER);
|
||||
cpufreq_dev_count++;
|
||||
list_add(&cpufreq_dev->node, &cpufreq_dev_list);
|
||||
|
||||
mutex_unlock(&cooling_cpufreq_lock);
|
||||
|
||||
@ -549,6 +553,7 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
|
||||
|
||||
cpufreq_dev = cdev->devdata;
|
||||
mutex_lock(&cooling_cpufreq_lock);
|
||||
list_del(&cpufreq_dev->node);
|
||||
cpufreq_dev_count--;
|
||||
|
||||
/* Unregister the notifier for the last cpufreq cooling device */
|
||||
|